York Understanding 's Model Number Nomenclature for DM Series Air Conditioners

Page 3

262259-YTG-B-0107

PRODUCT NOMENCLATURE

15-25 Ton Sunline 2000™ Model Number Nomenclature

D M 180 N24 A 2 A AA 1 0 1 2 4 A

Product Category

D = A/C, Single Pkg., R-22

Product Identifier

M = 8.5-9.0 EER A/C

Nominal Cooling Capacity

180 = 15 Ton

240 = 20 Ton

300 = 25 Ton

Heat Type and Nominal Heat Capacity

C00 = Cooling Only. No field installed electric heat

Gas Heat Options

N24 = 240 MBH Output Aluminized Steel

N32 = 320 MBH Output Aluminized Steel

S24 = 240 MBH Output Stainless Steel

S32 = 320 MBH Output Stainless Steel

Electric Heat Options

E18 = 18 KW

E36 = 36 KW

E54 = 54 KW

E72 = 72 KW

Airflow

A = Std. Drive

B = Std. Drive/Single Input Econo.

C = Std. Drive/Single Input Econo./Power Exhaust (Downflow Only)

D = Std. Drive/Motorized Damper N = Hi Static Drive

P = Hi Static Drive/Single Input Econo.

Q = Hi Static Drive/Single Input Econo./Power Exhaust (Downflow Only)

R = Hi Static Drive/Motorized Damper

Voltage

2 = 208/230-3-60

4 = 460-3-60

5 = 575-3-60

Product Style

A = Style A

Configuration Options (not required for all units)

These four digits will not be assigned until a quote is requested, or an order placed.

SS Drain Pan

CPC Controller, DFS, APS

Johnson Controller, DFS, APS

Honeywell Controller, DFS, APS

Novar Controller, DFS, APS

Simplicity IntelliComfort Controller

Simplicity IntelliComfort Controller w/ModLinc

Hot Gas Bypass (Standard on VAV, Optional on CV)

Variable Air Volume (VFD) - Not Available with Factory Installed BAS Options

Variable Air Volume (VFD With Manual Bypass) - Not Available with Factory Installed BAS Options Variable Air Volume (VFD-Ready for Customer Installed Drive)

2" Pleated filters 4" Pleated filters

BAS Ready Unit with Belimo Economizer

Double Wall Construction

Heat Reclaim Coil Options (2 or 3 Row, 1-5/8" or 2-1/8" Stub Out) (WJ and WR models only)

Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned

 

 

Product Generation

 

 

 

 

 

 

 

 

 

 

1 = First Generation

 

 

 

 

2 = Second Generation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Additional Options

 

 

 

 

 

 

Standard Cabinet

Hinged Filter Door & Toolless Access Cabinet

 

 

 

 

AA = None

BA = Hinged Filter Door & Toolless Access Panels

 

AB = Phase Monitor

BB = Phase Monitor, Hinged Filter Door & Toolless

 

AC = Coil Guard

Access Panels

 

AD = Dirty Filter Switch

BC = Coil Guard, Hinged Filter Door & Toolless

 

AE = Phase Monitor & Coil Guard

Access Panels

 

AF = Phase Monitor & Dirty Filter Switch

BD = Dirty Filter Switch, Hinged Filter Door &

 

AG = Coil Guard & Dirty Filter Switch

Toolless Access Panels

 

AH = Phase Monitor, Coil Guard & Dirty Filter Switch

BE = Phase Monitor & Coil Guard, Hinged Filter

 

RC = Coil Guard & American Flag

Door & Toolless Access Panels

 

TA = Technicoat Condenser Coil

BF = Phase Monitor & Dirty Filter Switch, Hinged

 

TJ = Technicoat Evaporator Coil

Filter Door & Toolless Access Panels

 

TS = Technicoat Evaporator & Condenser Coils

BG = Coil Guard & Dirty Filter Switch, Hinged Filter

 

 

 

 

 

Door & Toolless Access Panels

 

 

 

 

 

BH = Phase Monitor, Coil Guard & Dirty Filter Switch,

 

 

 

 

 

Hinged Filter Door & Toolless Access Panels

 

 

 

 

ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be

 

 

located in digits 15-18.

 

 

 

 

 

 

 

 

 

 

Installation Options

 

 

 

 

 

A = No Options Installed

 

B = Option 1

 

C = Option 2

 

D = Options 1 & 2

 

E = Option 3

 

F = Option 4

 

G = Options 1 & 3

 

H = Options 1 & 4

 

J = Options 1, 2 & 3

 

K = Options 1, 2, & 4

 

L = Options 1,3 & 4

 

M = Options 1, 2, 3, & 4

 

N = Options 2 & 3

 

P = Options 2 & 4

 

Q = Options 2, 3, & 4

 

R = Options 3 & 4

 

S = Option 5

 

T = Options 1 & 5

 

U = Options 1, 3, & 5

 

V = Options 1, 4, & 5

 

W = Options 1, 3, 4, & 5

 

X = Options 3 & 5

 

Y = Options 4 & 5

 

Z = Options 3, 4 & 5

 

 

 

 

 

 

Options

 

1 = Disconnect

2= Non-Pwr'd Conv. Outlet

3 = Smoke Detector S.A.

4 = Smoke Detector R.A.

5 = Pwr'd Conv. Outlet

Unitary Products Group

3

Image 3
Contents Description Technical GuideTable of Contents Ton Sunline 2000 Model Number Nomenclature Product NomenclatureFeatures Unit Cutaway FACTORY-INSTALLED OptionsFor 5-hp motor applications FIELD-INSTALLED Accessories YTG-B-0107 Sound Power RATING1 Capacity Ratings ARIGAS Heat Ratiings CAP.1 INPUT2 CFM MBH DM 180 Cooling Capacities 15 TONTotal Power Sensible CAPACITY, MBH DM 240 Cooling Capacities 20 TON 78.1 DM 300 Cooling Capacities 25 TON 49.2 AIR Temp Altitude Feet Altitude Correction FactorsALTITUDE/TEMPERATURE Conversion Factor Motor CFM Pulley Speed 6000 7000 8000 9000 9400 965 980 1025 1065 1125 1170 870 900 930 950 980 995 1015 7500 8750 10000 11250 12500 Power Exhaust Performance Blower Motor and Drive DataStatic RESISTANCES1 Compressors Heater Option MIN 300 DM 180, 240 Electrical Data with Powered Convenience Outlet None 139.3 175 E18 13.5 37.5 Physical Data DM Voltage LIMITATIONS1Electric Heat Correction Factors Supply FAN VFD WEIGHTS, in LBSFront View Rear View Dimensions Minimum Clearances Unit Dimensions DM180, 240 & 300 RainhoodCenter of Gravity Four and SIX Point Loads Unit Roof Curb Dimensions Typical Simplicity Control Wiring Diagram Guide Specifications GeneralDescription Refrigerant Components Other Factory Installed Options YTG-B-0107

DM 180, DM 240, DM 300 specifications

The York DM series, including the DM 240, DM 180, and DM 300, represents a blend of efficiency, advanced technology, and reliability in the world of HVAC solutions. Designed for commercial and industrial applications, these models cater to diverse temperature control needs while maintaining energy efficiency.

The York DM 240 is engineered to provide powerful cooling and heating performance in a compact unit. It features a robust design that incorporates high-efficiency compressors and environmentally friendly refrigerants. The DM 240 boasts advanced microprocessor controls, allowing for precise temperature regulation and operational monitoring. This model is particularly known for its low noise levels, making it suitable for areas requiring a quieter environment.

The DM 180 model is similarly designed but tailored for smaller applications while still delivering exceptional energy performance. Enhanced with variable-speed fans, the DM 180 can adjust its airflow based on real-time demand, ensuring optimal comfort and reduced energy consumption. This unit also includes advanced diagnostic tools that streamline maintenance and troubleshooting, thus minimizing downtime.

The DM 300 stands out with its increased capacity and enhanced features for larger facilities. Known for its superior cooling efficiency, the DM 300 utilizes advanced inverter technology. This allows the system to vary the speed of the compressor and fans, resulting in significant energy savings and improved load matching. Additionally, the DM 300 incorporates smart connectivity features that enable remote monitoring and control via smartphone or PC, facilitating effortless management of your HVAC system.

All three models in the York DM series incorporate cutting-edge technologies, including enhanced filtration systems that improve indoor air quality by reducing airborne particles. These systems are designed to work seamlessly with modern building management systems, enabling integration and optimization of overall HVAC operations.

Durability is a noteworthy characteristic of the York DM series, as each unit is built with high-quality materials to withstand demanding environments. With easy access to components, maintenance is simplified, helping to extend the lifespan of the equipment.

In summary, the York DM 240, DM 180, and DM 300 models exemplify modern HVAC technology, combining efficiency, advanced features, and user-friendly interfaces for robust climate control solutions in any commercial or industrial setting.