York H*RC018 THRU 060, H*RC036S warranty Furnace, Total Sens

Page 7

036-21137-004 Rev. C (0505)

COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils

 

FURNACE**

COIL

 

 

COOLING

 

 

UNIT MODEL

CFM RANGE

W

MODEL

RATED CFM

NET MBH

SEER

SEER + TXV1

EER

 

(Min.-max.)

 

 

 

TOTAL

SENS.

W/O TXV

 

 

 

 

14,17

G1FA024S14,17

600

19.2

13.0

12.00*

12.00

11.35

 

 

14

G1HA024H14

600

19.2

13.6

12.00*

11.50

 

 

14

G1HA024H14T

600

19.2

13.6

12.00*

11.60

 

 

-

G1HD024

600

20.0

13.5

12.50*

12.50

11.70

H2RC018S06

525

17

G1NA030S17K

600

20.0

13.5

12.75*

12.75

11.75

21

G1NA030S21M

600

20.0

13.5

12.50*

12.50

11.75

675

 

 

14,17

G1UA024S14,17

600

19.2

13.0

12.00*

12.00

11.35

 

 

14,17

G2FD024(S,H)14,17

600

19.6

13.2

12.50*

12.50

11.60

 

 

17

G2FD030(S,H)17

600

20.0

13.5

12.60*

12.60

11.75

 

 

14

G2FD035(S,H)14

600

20.0

13.5

12.60*

12.60

11.75

 

 

14,17

G1FA024S14,17

750

23.0

16.4

11.80*

11.80

10.70

 

 

14

G1FA030S14

750

23.6

16.9

12.00*

12.00

11.00

 

 

14

G1FA036S14

750

24.2

17.6

12.00*

12.00

11.25

 

 

17,21

G1FA036S17,21

750

24.0

17.3

12.00*

12.00

11.10

 

 

14

G1HA024H14

750

19.2

13.6

12.00*

10.90

 

 

14

G1HA024H14T

800

23.5

16.7

12.00*

10.90

 

 

14

G1HA036H14

800

24.6

17.5

12.00

11.35

 

 

-

G1HD024

750

24.0

17.2

12.00*

12.00

11.05

 

 

-

G1HD036

750

24.6

17.6

12.10*

12.10

11.35

H2RC024S06

650

17

G1NA030S17K

750

24.0

17.2

12.00*

12.00

11.15

850

 

 

 

 

 

 

 

 

21

G1NA030S21M

750

24.0

17.2

12.00*

12.00

11.15

 

 

 

14,17

G1UA024S14,17

750

23.0

16.4

11.80*

11.80

10.70

 

 

14

G1UA030S14

750

23.6

16.9

12.00*

12.00

11.00

 

 

14

G1UA036S14

750

24.2

17.6

12.00*

12.00

11.25

 

 

17,21

G1UA036S17,21

750

24.0

17.3

12.00*

12.00

11.10

 

 

14,17

G2FD024(S,H)14,17

750

23.6

16.9

12.00*

12.00

11.00

 

 

17

G2FD030(S,H)17

750

24.0

17.3

12.00*

12.00

11.10

 

 

14

G2FD035(S,H)14

750

24.0

17.3

12.10*

12.10

11.10

 

 

17

G2FD036(S,H)17

750

24.6

17.8

12.15*

12.15

11.35

 

 

14

G1FA030S14

1000

29.2

20.7

11.85*

11.85

10.80

 

 

14

G1FA036S14

1000

30.4

21.6

12.00*

12.00

11.10

 

 

17,21

G1FA036S17,21

1000

30.0

21.3

12.00*

12.00

11.00

 

 

17

G1FA048S17

1000

31.2

22.3

12.50*

12.50

11.45

 

 

21

G1FA048S21

1000

31.2

22.3

12.50*

12.50

11.35

 

 

14

G1HA036H14

1000

30.3

21.5

12.00*

11.25

 

 

14

G1HA036H14

1000

30.2

21.4

12.00*

11.25

 

 

17

G1HA036H17

1000

30.4

21.9

12.00*

11.35

 

 

17

G1HA036H17T

1000

30.5

22.0

12.00*

11.35

 

 

-

G1HD036

1000

30.8

21.9

12.75*

12.75

11.25

 

 

17

G1NA030S17K

1000

30.2

21.4

12.00*

12.00

11.05

H2RC030S06

875

21

G1NA030S21M

1000

30.2

21.4

12.00*

12.00

11.05

1125

 

 

 

 

 

 

 

 

17

G1NA036S17L

1000

31.4

22.3

12.50*

12.50

11.45

 

 

 

14

G1UA030S14

1000

29.2

20.7

11.85*

11.85

10.80

 

 

14

G1UA036S14

1000

30.4

21.6

12.00*

12.00

11.10

 

 

17,21

G1UA036S17,21

1000

30.0

21.3

12.00*

12.00

11.00

 

 

17

G1UA048S17

1000

31.2

22.3

12.50*

12.50

11.45

 

 

21

G1UA048S21

1000

31.2

22.3

12.50*

12.50

11.35

 

 

17

G2FD030(S,H)17

1000

30.0

21.3

12.00*

12.00

11.00

 

 

14

G2FD035(S,H)14

1000

30.0

21.3

12.00*

12.00

11.00

 

 

17

G2FD036(S,H)17

1000

30.6

21.8

12.25*

12.25

11.20

 

 

21

G2FD036(S,H)21

1000

30.8

21.9

12.25*

12.25

11.25

 

 

21

G2FD042(S,H)21

1000

31.0

22.1

12.50*

12.50

11.35

 

 

17

G2FD046(S,H)17

1000

31.4

22.3

12.50*

12.50

11.45

For Notes See Page 9.

Unitary Products Group

7

Image 7
Contents Features WarrantyDescription Model Physical and Electrical Data 1 PhasePhysical and Electrical Data 3 Phase ModelIndoor Coil5 G1NF060SOF ProceduresG1NF024SOF G1NF036SOF G1NF048SOFUnit Orifice s Factory R-22 Charge, lbs-oz Outdoor UnitSeer AC with N1AH / G2FD Cooling Capacity With Air Handler CoilsWith TXV3 SensTotal Sens Furnace1200 33.6 23.4 1575 45.5 34.1 12.00 SPEED3 Cooling Capacity With Variable Speed FurnacesTotal Sens TXV + TXV2P1XDC20V DUC20VSound Power Ratings Dimensions 1 PhaseDimensions 3 Phase AccessoriesTypical Field Wiring 1 Phase Application Typical InstallationTypical Field Wiring 3 Phase Application H2RC018S06 Cooling Performance DataG1FA024S14,17 G1FA036S17,21 H2RC024S06H2RC030S06 P1DUC20V H2RC036S06G1FA048S21 N1VSC16H1RC036S25,46 H2RC042S06 N1VSD20 H2RC048S06H1RC048S25,46 G1FA060S21,24 H4RC060S06N1AHD20 H1RC060S25,46 Unitary 5005 Norman Products York Group Drive 73069 Matching Indoor Components

H*RC018 THRU 060, H*RC036S specifications

The York H*RC036S and H*RC018 through H*RC060 are high-performance, energy-efficient rooftop units designed for commercial and industrial applications. These units are engineered to deliver exceptional heating and cooling performance while maintaining a low environmental impact. Both models leverage advanced technologies to ensure optimal indoor climate control and enhanced user comfort.

One of the standout features of the York H*RC series is its cutting-edge inverter technology. This innovation allows the units to adjust their cooling and heating capacity based on real-time demand, enabling significant energy savings. By operating at varying speeds, these rooftop units minimize energy consumption during off-peak times, contributing to a reduced overall carbon footprint.

The H*RC series is equipped with advanced microprocessor controls, which streamline operational management and provide users with precise control over their HVAC systems. The intuitive interface allows for easy programming and monitoring of performance, ensuring that users can maintain an ideal indoor environment with minimal effort.

In terms of construction, the H*RC units boast a robust build, designed to withstand harsh weather conditions while ensuring long-term durability. The units are equipped with high-efficiency fans and heat exchangers that optimize airflow and thermal exchange, enhancing overall performance and reliability.

Noise reduction is another key characteristic of the York H*RC series. These rooftop units are designed with sound-dampening features that minimize operational noise, making them suitable for noise-sensitive environments such as hospitals, schools, and office buildings.

The H*RC series also incorporates advanced filtration systems to improve indoor air quality. These systems effectively remove pollutants and allergens from the air, contributing to a healthier and more comfortable living and working environment.

Additionally, the York H*RC036S and H*RC018 through H*RC060 models are compliant with the latest regulations and standards, ensuring that they deliver efficient performance while adhering to environmental guidelines.

With a wide range of capacities and configurations available, the York H*RC series is versatile and can be tailored to meet specific application needs. Overall, these rooftop units represent a perfect blend of technology, energy efficiency, and reliability, making them an excellent choice for commercial and industrial HVAC applications.