York H*RC018 THRU 060, H*RC036S Typical Installation, Typical Field Wiring 1 Phase Application

Page 13

036-21137-004 Rev. C (0505)

TYPICAL INSTALLATION

 

MINIMUM 18” SERVICE ACCESS

THERMOSTAT

TO FURNACE OR

60” OVERHEAD

CLEARANCE ON ONE SIDE

 

 

AIR HANDLER

CLEARANCE

WEATHERPROOF

 

 

TERMINAL BLOCK

 

DISCONNECT

 

 

 

 

 

SWITCH

 

NEC CLASS 1 WIRING

 

 

 

NEC CLASS 2 WIRING

10” CLEARANCE

 

 

TO INDOOR COIL

COIL AREA

 

 

NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF.

SEAL OPENING(S) WITH

PERMAGUM OR EQUIVALENT

CONTROL ACCESS PANEL

TYPICAL FIELD WIRING - 1 Phase Application

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

POWER WIRING

208/230-1-60

POWER WIRING

24 VOLT CONTROL WIRING

 

CONTROL WIRING

MINIMUM 18 GA. WIRE

 

 

 

 

FACTORY WIRING

(NEC CLASS 2)

 

 

 

 

 

 

FURNACE OR AIR HANDLER TERMINAL BLOCK

CONTACTOR

TERMINALS

GND.

LUGCOIL

CONDENSING UNIT

C Y R G W

* TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT.

*

Y R G W

ROOM THERMOSTAT

ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.

TYPICAL FIELD WIRING - 3 Phase Application

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

GND.

LUG

POWER WIRING

208/230-3-60

460-3-60

CONTACTOR TERMINALS

COIL

24 VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2)

*TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT.

POWER WIRING

CONTROL WIRING

FACTORY WIRING

FURNACE OR AIR HANDLER TERMINAL BLOCK

C Y R G W

YR G W *

CONDENSING UNIT

ROOM THERMOSTAT

ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.

Unitary Products Group

13

Image 13
Contents Features WarrantyDescription Physical and Electrical Data 3 Phase Physical and Electrical Data 1 PhaseModel ModelIndoor Coil5 G1NF024SOF G1NF036SOF ProceduresG1NF048SOF G1NF060SOFUnit Orifice s Factory R-22 Charge, lbs-oz Outdoor UnitWith TXV3 Cooling Capacity With Air Handler CoilsSens Seer AC with N1AH / G2FDTotal Sens Furnace1200 33.6 23.4 1575 45.5 34.1 12.00 Total Sens TXV Cooling Capacity With Variable Speed Furnaces+ TXV2 SPEED3P1XDC20V DUC20VDimensions 3 Phase Dimensions 1 PhaseAccessories Sound Power RatingsTypical Field Wiring 1 Phase Application Typical InstallationTypical Field Wiring 3 Phase Application H2RC018S06 Cooling Performance DataG1FA024S14,17 G1FA036S17,21 H2RC024S06H2RC030S06 G1FA048S21 H2RC036S06N1VSC16 P1DUC20VH1RC036S25,46 H2RC042S06 N1VSD20 H2RC048S06H1RC048S25,46 G1FA060S21,24 H4RC060S06N1AHD20 H1RC060S25,46 Unitary 5005 Norman Products York Group Drive 73069 Matching Indoor Components

H*RC018 THRU 060, H*RC036S specifications

The York H*RC036S and H*RC018 through H*RC060 are high-performance, energy-efficient rooftop units designed for commercial and industrial applications. These units are engineered to deliver exceptional heating and cooling performance while maintaining a low environmental impact. Both models leverage advanced technologies to ensure optimal indoor climate control and enhanced user comfort.

One of the standout features of the York H*RC series is its cutting-edge inverter technology. This innovation allows the units to adjust their cooling and heating capacity based on real-time demand, enabling significant energy savings. By operating at varying speeds, these rooftop units minimize energy consumption during off-peak times, contributing to a reduced overall carbon footprint.

The H*RC series is equipped with advanced microprocessor controls, which streamline operational management and provide users with precise control over their HVAC systems. The intuitive interface allows for easy programming and monitoring of performance, ensuring that users can maintain an ideal indoor environment with minimal effort.

In terms of construction, the H*RC units boast a robust build, designed to withstand harsh weather conditions while ensuring long-term durability. The units are equipped with high-efficiency fans and heat exchangers that optimize airflow and thermal exchange, enhancing overall performance and reliability.

Noise reduction is another key characteristic of the York H*RC series. These rooftop units are designed with sound-dampening features that minimize operational noise, making them suitable for noise-sensitive environments such as hospitals, schools, and office buildings.

The H*RC series also incorporates advanced filtration systems to improve indoor air quality. These systems effectively remove pollutants and allergens from the air, contributing to a healthier and more comfortable living and working environment.

Additionally, the York H*RC036S and H*RC018 through H*RC060 models are compliant with the latest regulations and standards, ensuring that they deliver efficient performance while adhering to environmental guidelines.

With a wide range of capacities and configurations available, the York H*RC series is versatile and can be tailored to meet specific application needs. Overall, these rooftop units represent a perfect blend of technology, energy efficiency, and reliability, making them an excellent choice for commercial and industrial HVAC applications.