York H*RC036S, H*RC018 THRU 060 warranty 1200 33.6 23.4

Page 8

036-21137-004 Rev. C (0505)

COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Continued)

 

FURNACE**

COIL

 

 

COOLING

 

 

UNIT MODEL

CFM RANGE

W

MODEL

RATED CFM

NET MBH

SEER

SEER + TXV1

EER

 

(Min.-max.)

 

 

 

TOTAL

SENS.

W/O TXV

 

 

 

 

14

G1FA036S14

1200

33.6

23.4

11.50*

11.50

10.60

 

 

17,21

G1FA036S17,21

1200

33.0

23.0

11.25*

11.25

10.45

 

 

17

G1FA048S17

1200

35.0

24.4

12.00*

12.00

10.90

 

 

21

G1FA048S21

1200

34.0

25.2

12.00*

12.00

10.70

 

 

14

G1HA036H14

1150

33.5

23.8

12.00*

10.75

 

 

14

G1HA036H14

1150

33.4

23.7

12.00*

10.75

 

 

17

G1HA036H17

1200

34.0

24.5

12.00*

10.80

 

 

17

G1HA036H17T

1200

34.0

24.5

12.00*

10.80

 

 

21

G1HA048H21

1200

34.0

24.8

12.00*

10.70

 

 

21

G1HA048H21T

1200

33.3

24.3

12.00

10.70

 

 

-

G1HD036

1200

34.0

23.7

11.80*

11.80

10.70

 

 

-

G1HD048

1200

35.4

24.7

12.00*

12.00

11.00

H2RC036S06

1050

17

G1NA036S17L

1200

35.0

24.8

12.00*

12.00

10.90

1350

 

 

 

 

 

 

 

 

21

G1NA048S21D

1200

35.0

24.8

12.00*

12.00

10.90

 

 

 

14

G1UA036S14

1200

33.6

23.4

11.50*

11.50

10.60

 

 

17,21

G1UA036S17,21

1200

33.0

23.0

11.25*

11.25

10.45

 

 

17

G1UA048S17

1200

35.0

24.4

12.00*

12.00

10.90

 

 

21

G1UA048S21

1200

34.0

25.2

12.00*

12.00

10.70

 

 

21

G1NA048S21D

1200

35.0

25.2

12.00*

12.00

10.40

 

 

14

G2FD035(S,H)14

1200

33.0

23.0

11.25*

11.25

10.45

 

 

17

G2FD036(S,H)17

1200

33.8

23.6

11.50*

11.50

10.70

 

 

21

G2FD036(S,H)21

1200

34.2

23.8

12.50*

12.50

10.75

 

 

21

G2FD042(S,H)21

1200

34.6

24.1

12.00*

12.00

10.80

 

 

17

G2FD046(S,H)17

1200

35.0

24.4

12.00*

12.00

10.90

 

 

21,24

G2FD048(S,H)21,24

1200

36.0

25.1

12.10*

12.10

11.10

 

 

14

G1FA036S14

1235

33.4

25.0

11.50

10.65

 

 

17,21

G1FA036S17,21

1235

33.0

24.4

11.50

10.55

 

 

21

G1FA048S21

1235

35.0

25.9

12.00

10.70

 

 

-

G1HD036

1235

33.4

24.7

11.80

10.70

 

 

-

G1HD048

1235

35.0

25.8

12.00

11.05

 

 

17

G1NA036S17L

1200

35.0

24.4

12.00

10.90

 

 

21

G1NA048S21D

1200

35.0

24.4

12.00

10.90

H1RC036S(25,46)

1050

14

G1UA036S14

1200

33.4

25.0

11.50

10.65

1350

17,21

G1UA036S17,21

1235

33.0

24.4

11.50

10.55

 

 

 

21

G1UA048S21

1235

35.0

25.9

12.00

10.70

 

 

14

G2FD035(S,H)14

1200

32.8

24.3

11.55

10.55

 

 

17

G2FD036(S,H)17

1250

33.6

24.9

12.00

10.65

 

 

21

G2FD036(S,H)21

1200

34.2

25.3

12.00

10.90

 

 

21

G2FD042(S,H)21

1235

34.4

25.5

12.00

10.90

 

 

17

G2FD046(S,H)17

1250

34.8

25.8

12.00

10.95

 

 

21,24

G2FD048(S,H)21,24

1250

35.4

26.2

12.10

11.15

 

 

17

G1FA048S17

1400

42.0

30.2

12.00*

10.60

 

 

21

G1FA048S21

1400

41.5

29.7

12.00

10.65

 

 

21,24

G1FA060S21,24

1400

43.0

30.7

12.50

10.95

 

 

21

G1HA048H21

1400

41.5

30.3

12.00*

10.65

 

 

21

G1HA048H21T

1400

40.7

29.7

12.00

10.65

 

 

-

G1HD048

1400

41.5

29.7

12.00

10.60

H2RC042S06

1225

21

G1NA048S21D

1400

41.0

28.6

12.00*

10.40

1575

 

 

 

 

 

 

 

 

17

G1UA048S17

1400

42.0

30.2

12.00*

10.60

 

 

 

21

G1UA048S21

1400

41.5

29.7

12.00

10.65

 

 

21,24

G1UA060S21,24

1400

43.0

30.7

12.50*

10.95

 

 

21

G2FD042(S,H)21

1400

41.0

29.3

12.00*

10.50

 

 

17

G2FD046(S,H)17

1400

42.0

30.2

12.00*

10.60

 

 

21,24

G2FD048(S,H)21,24

1400

42.5

30.6

12.00

10.75

For Notes See Page 9.

8

Unitary Products Group

Image 8
Contents Description WarrantyFeatures Physical and Electrical Data 1 Phase Physical and Electrical Data 3 PhaseModel ModelIndoor Coil5 Procedures G1NF024SOF G1NF036SOFG1NF048SOF G1NF060SOFOutdoor Unit Unit Orifice s Factory R-22 Charge, lbs-ozCooling Capacity With Air Handler Coils With TXV3Sens Seer AC with N1AH / G2FDFurnace Total Sens1200 33.6 23.4 1575 45.5 34.1 12.00 Cooling Capacity With Variable Speed Furnaces Total Sens TXV+ TXV2 SPEED3DUC20V P1XDC20VDimensions 1 Phase Dimensions 3 PhaseAccessories Sound Power RatingsTypical Field Wiring 3 Phase Application Typical InstallationTypical Field Wiring 1 Phase Application G1FA024S14,17 Cooling Performance DataH2RC018S06 H2RC024S06 G1FA036S17,21H2RC030S06 H2RC036S06 G1FA048S21N1VSC16 P1DUC20VH1RC036S25,46 H2RC042S06 H2RC048S06 N1VSD20H1RC048S25,46 N1AHD20 H4RC060S06G1FA060S21,24 H1RC060S25,46 Matching Indoor Components Unitary 5005 Norman Products York Group Drive 73069

H*RC018 THRU 060, H*RC036S specifications

The York H*RC036S and H*RC018 through H*RC060 are high-performance, energy-efficient rooftop units designed for commercial and industrial applications. These units are engineered to deliver exceptional heating and cooling performance while maintaining a low environmental impact. Both models leverage advanced technologies to ensure optimal indoor climate control and enhanced user comfort.

One of the standout features of the York H*RC series is its cutting-edge inverter technology. This innovation allows the units to adjust their cooling and heating capacity based on real-time demand, enabling significant energy savings. By operating at varying speeds, these rooftop units minimize energy consumption during off-peak times, contributing to a reduced overall carbon footprint.

The H*RC series is equipped with advanced microprocessor controls, which streamline operational management and provide users with precise control over their HVAC systems. The intuitive interface allows for easy programming and monitoring of performance, ensuring that users can maintain an ideal indoor environment with minimal effort.

In terms of construction, the H*RC units boast a robust build, designed to withstand harsh weather conditions while ensuring long-term durability. The units are equipped with high-efficiency fans and heat exchangers that optimize airflow and thermal exchange, enhancing overall performance and reliability.

Noise reduction is another key characteristic of the York H*RC series. These rooftop units are designed with sound-dampening features that minimize operational noise, making them suitable for noise-sensitive environments such as hospitals, schools, and office buildings.

The H*RC series also incorporates advanced filtration systems to improve indoor air quality. These systems effectively remove pollutants and allergens from the air, contributing to a healthier and more comfortable living and working environment.

Additionally, the York H*RC036S and H*RC018 through H*RC060 models are compliant with the latest regulations and standards, ensuring that they deliver efficient performance while adhering to environmental guidelines.

With a wide range of capacities and configurations available, the York H*RC series is versatile and can be tailored to meet specific application needs. Overall, these rooftop units represent a perfect blend of technology, energy efficiency, and reliability, making them an excellent choice for commercial and industrial HVAC applications.