York WR300, WR240 warranty Power exhaust is not available as a field installed option

Page 10

262292-YTG-B-0107

Power exhaust is not available as a field installed option.

ROOF CURBS - Fourteen-inch high roof curbs provide a water-tight seal between the unit and the finished roof. These full perimeter curbs meet the requirements of the National Roofing Contractors Association (NRCA) and are shipped knocked-down for field assembly.

They're designed to fit inside the base rails of the unit and include both a wood nailing strip and duct hanger supports.

HIGH ALTITUDE NATURAL GAS - Burner orifices and pilot orifices are provided for proper furnace operation at altitudes up to 6,000 feet.

PROPANE - Burner orifices, pilot orifices and gas valve parts are provided to convert a natural gas furnace to propane.

HIGH ALTITUDE PROPANE - Burner orifices and pilot orifices are provided for proper furnace operation at altitudes up to 6,000 feet. This accessory supplements the basic propane conversion kit.

SIDE DUCT FLANGES - One-inch flanges replace the supply and return air panels on the rear of the unit to accommodate horizontal duct connections. These flanges can also be used individually for bottom supply/horizontal return or horizontal supply/bottom return. They cannot be used on units with power exhaust.

BAROMETRIC RELIEF DAMPER - This damper accessory can be used to relieve internal building air

pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct.

ENTHALPY ACCESSORY CONTROL KIT - This kit contains the required components to convert a single enthalpy economizer to dual enthalpy.

BURGLAR BARS - Mount in the supply and return openings to prevent entry into the duct work.

FLUE EXHAUST EXTENSION KIT - In locations with wind or weather conditions which may interfere with proper exhausting of furnace combustion products, this kit can be installed to prevent the flue exhaust from entering nearby fresh air intakes.

WOOD SKID - Allows unit to be handled with 90” forks.

CO2 SENSOR - Senses CO2 levels and automatically overrides the economizer when levels rise above the present limits.

COIL GUARD - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit.

PHASE MONITORS - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-of- phase condition.

10

Unitary Products Group

Image 10
Contents Warranty DescriptionTable of Contents Product Nomenclature Ton Sunline MagnaDRY Model Number NomenclatureFeatures Normal Mode Unit CutawayAlternate Mode Reheat Control BoardReheat Controls Part Motorized Outdoor AIR Intake Damper FACTORY-INSTALLED OptionsSingle Input Electronic Enthalpy Phenolic Coated EVAPORATOR, REHEAT,FIELD-INSTALLED Accessories Power exhaust is not available as a field installed option Capacity Ratings ARI Sound Power RATING1GAS Heat Ratings Cooling Capacities for WR180 MBH104 151 16.9 142 118 101 147 15.2 Cooling Capacities for WR240 240 21.3 101 225 23.1 100 5000 221 21.0 140 Cooling Capacities for WR300 281 26.6 128 Cooling Capacities for WR180 Alternate Reheat Mode Cooling Capacities for WR240 Alternate Reheat Mode Cooling Capacities for WR300 Alternate Reheat Mode EV+U Lbs/Hr Lbs/Hr Altitude Correction Factors AIR Temp Altitude Feet$OWLWXGH7HPSHUDWXUH&RQYHUVLRQDFWRU ESP CFM RPM BHP Scfm Scfm Scfm Scfm Ton Standard Drive, Gas Heat, Bottom Connection VP68 x BK100 HP motor 10 HP motor 7.5 HP motor YTG-B-0107 12000 11000 8000 Ton High Static Drive, Cooling Only, Bottom Duct Connection Ton High Static Drive, Gas Heat, Bottom Duct Connection Blower Motor and Drive Data Power Exhaust PerformanceStatic RESISTANCES1 BRKR1 78.8 100 97.3 125 E18 13.5 37.5 86.5 100 88.8 107.3 125 E18 13.5 37.5 Physical Data Models WR180 WR240 WR300Hole Rear View Dimensions Unit Dimensions WR180, 240 & 300 Rainhood Minimum ClearancesUnit Center of Gravity Four and SIX Point Loads Unit Roof Curb Dimensions Typical Field Wiring Indoor Evaporator FAN Assembly Guide SpecificationsUnit Cabinet Unit Controls Outdoor Condenser FAN AssemblyRefrigerant Components GAS Heating Section WR***N ModelsOther Factory Installed Options Unit Operating CharacteristicsOther PRE-ENGINEERED Accessories Available Electrical RequirementsLOW Speed Drive WR240 & WR300 only

WR240, WR300 specifications

The York WR300 and WR240 are advanced water-cooled screw chillers that embody innovation, efficiency, and sustainability. These chillers are part of York’s renowned product line and are designed for a variety of commercial applications, ranging from large office buildings to industrial processes.

One of the standout features of the WR300 and WR240 models is their energy efficiency. Both units utilize the latest in variable-speed drive technology, which allows for precise control of the compressor speed based on the cooling demand. This results in lower energy consumption, especially in part-load conditions, making the chillers not only eco-friendly but also cost-effective over their lifespan.

The WR300 is designed to provide cooling capacities of up to 300 tons, while the WR240 offers capacities of up to 240 tons. These substantial capacities make them suitable for larger applications where dependable cooling is essential. The units are compact in design, allowing for flexible installation options, even in properties with space constraints.

Another key characteristic of the York WR chillers is their advanced refrigerant technology. Utilizing R-134a refrigerant, these chillers comply with global environmental standards and regulations, contributing to reduced greenhouse gas emissions. This makes the WR300 and WR240 not only high-performing but also aligned with a sustainable future.

The chillers are equipped with a robust control system that enhances operational performance and reliability. Features such as the advanced York YZ controller facilitate remote monitoring and diagnostics, allowing facility managers to optimize chiller performance and enhance maintenance processes. This advanced control capability minimizes downtime and maximizes productivity.

Noise reduction is also a significant consideration with these units. The WR series incorporates sound-dampening technology, making it an ideal choice for installations in noise-sensitive environments, such as schools or hospitals.

Furthermore, the construction of these chillers emphasizes durability and ease of maintenance. The components are engineered to withstand harsh operating conditions, and the design allows for straightforward access to key components, thereby simplifying service tasks.

In summary, the York WR300 and WR240 chillers stand out due to their energy efficiency, advanced refrigerant technology, robust control systems, and durability. These features make them ideal solutions for modern HVAC needs, supporting businesses while prioritizing environmental stewardship.