York WR240, WR300 warranty Guide Specifications, Unit Cabinet, Indoor Evaporator FAN Assembly

Page 53

262292-YTG-B-0107

GUIDE SPECIFICATIONS

GENERAL

Units shall be manufactured by York International Unitary Products Group in an ISO 9001 certified facility.

York's Sunline Magnum™ units are convertible single package units. All models have dual independent refrigerant circuits for efficient part load operation and maximum comfort control.

Although the units are primarily designed for curb mounting on a roof, they can also be slab-mounted at ground level or set on steel beams above a finished roof. Cooling only, cooling with gas heat and cooling with electric heat models are available with a wide variety of factory-mounted options and field- installed accessories to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails with holes in the four corners for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. Models with power exhaust are suitable for bottom duct connections only. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, replace the supply and return air panels on the rear of the unit with a side duct flange accessory. All supply air blowers are equipped with a belt drive that can be adjusted to meet the exact requirements of the job.

Each unit shall have 4 condenser fan motors. A high speed drive accessory is available for applications with a higher CFM and/or static pressure requirement. All compressors include crankcase heat and internal pressure relief. Every refrigerant circuit includes an expansion valve, a liquid line filter-drier, a discharge line high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch. The unit control circuit includes a 75 VA transformer, a 24-volt circuit breaker and a relay board with two compressor lockout circuits, a terminal strip for thermostat wiring, plus an additional set of pin connectors to simplify the interface of additional field controls. All units have long lasting powder paint cabinets with 1000 hour salt spray test approval under ASTM-B117 procedures. All 208/230 and 460-volt models are ETL approved. All 208/230 and 575-volt models are CGA approved. All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements carry an additional 4-year warranty. Aluminized steel tubular heat exchangers carry an additional 9-year warranty.

DESCRIPTION

Units shall be factory-assembled, single packaged, WR***N Electric Cooling/Gas Heat, WR***C/E Electric Cooling/Optional Electric Heat, designed for outdoor mounted installation. The 15 and 20 ton units shall have minimum EER ratings of 9.7. The 25 ton unit shall have a minimum EER rating of 9.5.

They shall have built-in field convertible duct connections for down discharge supply/return or horizontal discharge supply/ return, and be available with factory installed options or field installed accessories. The units shall be factory wired, piped, charged with R-22 refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units shall be manufactured in a facility certified to ISO 9001 standards and the cooling performance shall be rated in accordance with DOE and ARI test procedures. Units shall be ETL & CGA listed, classified to ANSIZ21.47 standards, UL 1995/CAN/CSA No. 236-M90 conditions.

UNIT CABINET

Unit cabinet shall be constructed of G90 galvanized steel, with exterior surfaces coated with a non-chalking, powdered paint finish, certified at 1000 hour salt spray test per ASTM-B117 standards. Indoor blower section shall be insulated with a minimum 1/2" thick insulation, coated on the airside. Aluminum foil faced insulation shall be used in the furnace compartment and be fastened with ridged fasteners to prevent insulation from entering the air stream. Cabinet panels shall be "large" size, easily removable for servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging and proper sealing on roof curb applications. Disposable 2" filters shall be furnished and be accessible through a removable access door, sealed airtight. Units filter track shall be designed to accommodate either 1" or 2" filters. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating air by-pass of the coils. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self- draining standards. Condensate connection shall be a minimum of 1" I.D. female and be a ridged mount connection. Unit shall incorporate a fixed outdoor air damper with an outdoor air intake opening covered with a bird screen and a rain hood painted to match the exterior of the unit.

INDOOR (EVAPORATOR) FAN ASSEMBLY

Fan shall be a belt drive assembly and include an adjustable- pitch motor pulley. Job site selected (B.H.P.) brake horsepower shall not exceed the motors nameplate horsepower rating, plus the service factor. Units shall be designed not to operate above service factor. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume.

A variable air volume (VAV) option using a variable frequency drive (VFD) is available for applications requiring a constant supply duct static pressure. Units equipped for VAV shall be controlled by a duct pressure transducer with a 0 - 5” WC pres- sure range. The pressure transducer shall provide a 0 - 5 VDC output signal to a VAV control board which, in turn shall provide a 2 - 10 VDC speed reference signal to the VFD. Units equipped with VFD’s shall have factory-installed manual bypass as an option.

Unitary Products Group

53

Image 53
Contents Description WarrantyTable of Contents Ton Sunline MagnaDRY Model Number Nomenclature Product NomenclatureFeatures Unit Cutaway Normal ModeReheat Control Board Alternate ModeReheat Controls Part Single Input Electronic Enthalpy FACTORY-INSTALLED OptionsMotorized Outdoor AIR Intake Damper Phenolic Coated EVAPORATOR, REHEAT,FIELD-INSTALLED Accessories Power exhaust is not available as a field installed option GAS Heat Ratings Sound Power RATING1Capacity Ratings ARI MBH Cooling Capacities for WR180104 151 16.9 142 118 101 147 15.2 Cooling Capacities for WR240 240 21.3 101 225 23.1 100 5000 221 21.0 140 Cooling Capacities for WR300 281 26.6 128 Cooling Capacities for WR180 Alternate Reheat Mode Cooling Capacities for WR240 Alternate Reheat Mode Cooling Capacities for WR300 Alternate Reheat Mode EV+U Lbs/Hr Lbs/Hr AIR Temp Altitude Feet Altitude Correction Factors$OWLWXGH7HPSHUDWXUH&RQYHUVLRQDFWRU ESP CFM RPM BHP Scfm Scfm Scfm Scfm Ton Standard Drive, Gas Heat, Bottom Connection VP68 x BK100 HP motor 10 HP motor 7.5 HP motor YTG-B-0107 12000 11000 8000 Ton High Static Drive, Cooling Only, Bottom Duct Connection Ton High Static Drive, Gas Heat, Bottom Duct Connection Static RESISTANCES1 Power Exhaust PerformanceBlower Motor and Drive Data BRKR1 78.8 100 97.3 125 E18 13.5 37.5 86.5 100 88.8 107.3 125 E18 13.5 37.5 WR180 WR240 WR300 Physical Data ModelsHole Rear View Dimensions Minimum Clearances Unit Dimensions WR180, 240 & 300 RainhoodUnit Center of Gravity Four and SIX Point Loads Unit Roof Curb Dimensions Typical Field Wiring Unit Cabinet Guide SpecificationsIndoor Evaporator FAN Assembly Refrigerant Components Outdoor Condenser FAN AssemblyUnit Controls GAS Heating Section WR***N ModelsOther PRE-ENGINEERED Accessories Available Unit Operating CharacteristicsOther Factory Installed Options Electrical RequirementsLOW Speed Drive WR240 & WR300 only

WR240, WR300 specifications

The York WR300 and WR240 are advanced water-cooled screw chillers that embody innovation, efficiency, and sustainability. These chillers are part of York’s renowned product line and are designed for a variety of commercial applications, ranging from large office buildings to industrial processes.

One of the standout features of the WR300 and WR240 models is their energy efficiency. Both units utilize the latest in variable-speed drive technology, which allows for precise control of the compressor speed based on the cooling demand. This results in lower energy consumption, especially in part-load conditions, making the chillers not only eco-friendly but also cost-effective over their lifespan.

The WR300 is designed to provide cooling capacities of up to 300 tons, while the WR240 offers capacities of up to 240 tons. These substantial capacities make them suitable for larger applications where dependable cooling is essential. The units are compact in design, allowing for flexible installation options, even in properties with space constraints.

Another key characteristic of the York WR chillers is their advanced refrigerant technology. Utilizing R-134a refrigerant, these chillers comply with global environmental standards and regulations, contributing to reduced greenhouse gas emissions. This makes the WR300 and WR240 not only high-performing but also aligned with a sustainable future.

The chillers are equipped with a robust control system that enhances operational performance and reliability. Features such as the advanced York YZ controller facilitate remote monitoring and diagnostics, allowing facility managers to optimize chiller performance and enhance maintenance processes. This advanced control capability minimizes downtime and maximizes productivity.

Noise reduction is also a significant consideration with these units. The WR series incorporates sound-dampening technology, making it an ideal choice for installations in noise-sensitive environments, such as schools or hospitals.

Furthermore, the construction of these chillers emphasizes durability and ease of maintenance. The components are engineered to withstand harsh operating conditions, and the design allows for straightforward access to key components, thereby simplifying service tasks.

In summary, the York WR300 and WR240 chillers stand out due to their energy efficiency, advanced refrigerant technology, robust control systems, and durability. These features make them ideal solutions for modern HVAC needs, supporting businesses while prioritizing environmental stewardship.