York WR300, WR240 warranty Table of Contents

Page 2

262292-YTG-B-0107

TABLE OF CONTENTS

DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 PRODUCT NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . .3 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 FACTORY-INSTALLED OPTIONS . . . . . . . . . . . . . . . . . . .8 FIELD-INSTALLED ACCESSORIES . . . . . . . . . . . . . . . . . .9 GUIDE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . .53

LIST OF FIGURES

Fig. #

Pg. #

1 UNIT CUTAWAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2 REHEAT CONTROL BOARD . . . . . . . . . . . . . . . . . . . . . 6 3 REHEAT CONTROLS - PART 1. . . . . . . . . . . . . . . . . . . 7 4 REHEAT CONTROLS - PART 2. . . . . . . . . . . . . . . . . . . 7 5 WR180 MOISTURE REMOVAL - ALT. MODE. . . . . . 21 6 WR180 MOISTURE REMOVAL - NORMAL MODE . . 21 7 WR240 MOISTURE REMOVAL - ALT. MODE. . . . . . 22 8 WR240 MOISTURE REMOVAL - NORMAL MODE . . 22 9 WR300 MOISTURE REMOVAL - ALT. MODE. . . . . . 23

10 WR300 MOISTURE REMOVAL - NORMAL MODE . . 23

11 ALTITUDE/TEMPERATURE CONVERSION FACTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

12 UNIT DIMENSIONS WR180, 240 & 300

(FRONT VIEW) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

13 REAR VIEW DIMENSIONS . . . . . . . . . . . . . . . . . . . . 47

14 UNIT DIMENSIONS WR180, 240 & 300 (RAINHOOD). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

15 UNIT CENTER OF GRAVITY . . . . . . . . . . . . . . . . . . . 49 16 TYPICAL UNIT APPLICATIONS . . . . . . . . . . . . . . . . 49 17 FOUR AND SIX POINT LOADS . . . . . . . . . . . . . . . . . 50 18 UNIT ROOF CURB DIMENSIONS . . . . . . . . . . . . . . . 51 19 ROOF CURB DUCT OPENINGS DIMENSION . . . . . 51 20 CUT AWAY OF ROOF CURB . . . . . . . . . . . . . . . . . . 51 21 TYPICAL FIELD WIRING . . . . . . . . . . . . . . . . . . . . . . 52

LIST OF TABLES

Tbl. #

Pg. #

1 SOUND POWER RATING . . . . . . . . . . . . . . . . . . . . . 11 2 CAPACITY RATINGS - (ARI 360) . . . . . . . . . . . . . . . 11 3 GAS HEAT RATINGS . . . . . . . . . . . . . . . . . . . . . . . . . 11 4 COOLING CAPACITIES FOR WR180 . . . . . . . . . . . . 12 5 COOLING CAPACITIES FOR WR240 . . . . . . . . . . . . 14 6 COOLING CAPACITIES FOR WR300 . . . . . . . . . . . . 16

7 COOLING CAPACITIES FOR WR180 (ALTERNATE REHEAT MODE). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

8 COOLING CAPACITIES FOR WR240 (ALTERNATE REHEAT MODE). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Tbl. #

Pg. #

9 COOLING CAPACITIES FOR WR300 (ALTERNATE REHEAT MODE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

10 ALTITUDE CORRECTION FACTORS . . . . . . . . . . . . . 24

11 WR180 BLOWER PERFORMANCE - 15 TON STD. DRIVE (COOLING ONLY) DOWNFLOW . . . . . . . . . . . 26

12 WR180 BLOWER PERFORMANCE - 15 TON STD. DRIVE (GAS HEAT) DOWNFLOW . . . . . . . . . . . . . . . 27

13 WR180 BLOWER PERFORMANCE - 15 TON HIGH STATIC DRIVE (COOLING ONLY) DOWNFLOW . . . . 28

14 WR180 BLOWER PERFORMANCE - 15 TON HIGH STATIC DRIVE (GAS HEAT) DOWNFLOW . . . . . . . . 29

15 WR240 BLOWER PERFORMANCE - 20 TON STD. DRIVE (COOLING ONLY) DOWNFLOW . . . . . . . . . . . 30

16 WR240 BLOWER PERFORMANCE - 20 TON STD. DRIVE (GAS HEAT) DOWNFLOW . . . . . . . . . . . . . . . 31

17 WR240 BLOWER PERFORMANCE - 20 TON HIGH STATIC DRIVE (COOLING ONLY) DOWNFLOW . . . . 32

18 WR240 BLOWER PERFORMANCE - 20 TON HIGH STATIC DRIVE (GAS HEAT) DOWNFLOW . . . . . . . . 33

19 WR300 BLOWER PERFORMANCE - 25 TON STD. DRIVE (COOLING ONLY) DOWNFLOW . . . . . . . . . . . 34

20 WR300 BLOWER PERFORMANCE - 25 TON STD. DRIVE (GAS HEAT) DOWNFLOW . . . . . . . . . . . . . . . 35

21 WR300 BLOWER PERFORMANCE - 25 TON HIGH STATIC DRIVE (COOLING ONLY) DOWNFLOW . . . . 36

22 WR300 BLOWER PERFORMANCE - 25 TON HIGH STATIC DRIVE (GAS HEAT) DOWNFLOW . . . . . . . . 37

23 BLOWER MOTOR AND DRIVE DATA . . . . . . . . . . . . 38 24 STATIC RESISTANCES . . . . . . . . . . . . . . . . . . . . . . . . 38 25 POWER EXHAUST PERFORMANCE . . . . . . . . . . . . . 38

26 WR ELECTRICAL DATA - STANDARD DRIVE MOTOR W/O POWERED CONV. OUTLET . . . . . . . . . 39

27 WR ELECTRICAL DATA - HIGH STATIC DRIVE MOTOR W/O POWERED CONV. OUTLET . . . . . . . . . 40

28 WR ELECTRICAL DATA - LOW AIRFLOW DRIVE MOTOR W/O POWERED CONV. OUTLET . . . . . . . . . 41

29 WR ELECTRICAL DATA - STANDARD DRIVE MOTOR WITH POWERED CONV. OUTLET . . . . . . . . 42

30 WR ELECTRICAL DATA - HIGH STATIC DRIVE MOTOR WITH POWERED CONV. OUTLET . . . . . . . . 43

31 WR ELECTRICAL DATA - LOW AIRFLOW DRIVE MOTOR WITH POWERED CONV. OUTLET . . . . . . . . 44

32 PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 33 SUPPLY FAN VFD WEIGHTS, IN LBS. . . . . . . . . . . . . 45 34 UTILITIES ENTRY DATA . . . . . . . . . . . . . . . . . . . . . . . 46 35 MINIMUM CLEARANCES . . . . . . . . . . . . . . . . . . . . . . 48 36 FOUR AND SIX POINT LOADS . . . . . . . . . . . . . . . . . . 50

2

Unitary Products Group

Image 2
Contents Warranty DescriptionTable of Contents Product Nomenclature Ton Sunline MagnaDRY Model Number NomenclatureFeatures Normal Mode Unit CutawayAlternate Mode Reheat Control BoardReheat Controls Part Motorized Outdoor AIR Intake Damper FACTORY-INSTALLED OptionsSingle Input Electronic Enthalpy Phenolic Coated EVAPORATOR, REHEAT,FIELD-INSTALLED Accessories Power exhaust is not available as a field installed option GAS Heat Ratings Sound Power RATING1Capacity Ratings ARI Cooling Capacities for WR180 MBH104 151 16.9 142 118 101 147 15.2 Cooling Capacities for WR240 240 21.3 101 225 23.1 100 5000 221 21.0 140 Cooling Capacities for WR300 281 26.6 128 Cooling Capacities for WR180 Alternate Reheat Mode Cooling Capacities for WR240 Alternate Reheat Mode Cooling Capacities for WR300 Alternate Reheat Mode EV+U Lbs/Hr Lbs/Hr Altitude Correction Factors AIR Temp Altitude Feet$OWLWXGH7HPSHUDWXUH&RQYHUVLRQDFWRU ESP CFM RPM BHP Scfm Scfm Scfm Scfm Ton Standard Drive, Gas Heat, Bottom Connection VP68 x BK100 HP motor 10 HP motor 7.5 HP motor YTG-B-0107 12000 11000 8000 Ton High Static Drive, Cooling Only, Bottom Duct Connection Ton High Static Drive, Gas Heat, Bottom Duct Connection Static RESISTANCES1 Power Exhaust PerformanceBlower Motor and Drive Data BRKR1 78.8 100 97.3 125 E18 13.5 37.5 86.5 100 88.8 107.3 125 E18 13.5 37.5 Physical Data Models WR180 WR240 WR300Hole Rear View Dimensions Unit Dimensions WR180, 240 & 300 Rainhood Minimum ClearancesUnit Center of Gravity Four and SIX Point Loads Unit Roof Curb Dimensions Typical Field Wiring Unit Cabinet Guide SpecificationsIndoor Evaporator FAN Assembly Unit Controls Outdoor Condenser FAN AssemblyRefrigerant Components GAS Heating Section WR***N ModelsOther Factory Installed Options Unit Operating CharacteristicsOther PRE-ENGINEERED Accessories Available Electrical RequirementsLOW Speed Drive WR240 & WR300 only

WR240, WR300 specifications

The York WR300 and WR240 are advanced water-cooled screw chillers that embody innovation, efficiency, and sustainability. These chillers are part of York’s renowned product line and are designed for a variety of commercial applications, ranging from large office buildings to industrial processes.

One of the standout features of the WR300 and WR240 models is their energy efficiency. Both units utilize the latest in variable-speed drive technology, which allows for precise control of the compressor speed based on the cooling demand. This results in lower energy consumption, especially in part-load conditions, making the chillers not only eco-friendly but also cost-effective over their lifespan.

The WR300 is designed to provide cooling capacities of up to 300 tons, while the WR240 offers capacities of up to 240 tons. These substantial capacities make them suitable for larger applications where dependable cooling is essential. The units are compact in design, allowing for flexible installation options, even in properties with space constraints.

Another key characteristic of the York WR chillers is their advanced refrigerant technology. Utilizing R-134a refrigerant, these chillers comply with global environmental standards and regulations, contributing to reduced greenhouse gas emissions. This makes the WR300 and WR240 not only high-performing but also aligned with a sustainable future.

The chillers are equipped with a robust control system that enhances operational performance and reliability. Features such as the advanced York YZ controller facilitate remote monitoring and diagnostics, allowing facility managers to optimize chiller performance and enhance maintenance processes. This advanced control capability minimizes downtime and maximizes productivity.

Noise reduction is also a significant consideration with these units. The WR series incorporates sound-dampening technology, making it an ideal choice for installations in noise-sensitive environments, such as schools or hospitals.

Furthermore, the construction of these chillers emphasizes durability and ease of maintenance. The components are engineered to withstand harsh operating conditions, and the design allows for straightforward access to key components, thereby simplifying service tasks.

In summary, the York WR300 and WR240 chillers stand out due to their energy efficiency, advanced refrigerant technology, robust control systems, and durability. These features make them ideal solutions for modern HVAC needs, supporting businesses while prioritizing environmental stewardship.