A Specifications
Desktop Dimensions
Height
Width
Depth (depth will increase if the computer is equipped with a port security bracket)
6.6 in | 16.7 cm |
17.65 in | 44.8 cm |
17.8 in | 45.2 cm |
Tower Dimensions |
|
|
| |
Height | 17.65 in | 44.8 cm | ||
Width | 6.6 in | 16.7 cm | ||
Depth (depth will increase if the computer is equipped with a | 17.8 in | 45.2 cm | ||
port security bracket) |
|
|
| |
|
|
|
|
|
Approximate Weight | 35 lb | 15.9 kg | ||
|
|
|
|
|
Weight Supported (maximum distributed load for Desktop | 100 lb | 45.5 kg | ||
configuration only) |
|
|
| |
|
|
|
|
|
Temperature Range |
|
|
| |
Operating | 50° to 95°F | 10° to 35°C | ||
Nonoperating | ||||
|
|
|
|
|
Relative Humidity (noncondensing) |
|
|
| |
Operating |
| |||
Nonoperating (38.7°C max wet bulb) |
| |||
|
|
|
|
|
Maximum Altitude (unpressurized) |
|
|
| |
Operating | 10,000 ft | 3048 m | ||
Nonoperating | 30,000 ft | 9144 m | ||
|
|
|
|
|
|
|
|
|
|
NOTE Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed.
Heat Dissipation |
|
|
Maximum | 1,916 BTU/hr | 483 |
Typical (idle) | 375 BTU/hr | 95 |
|
|
|
Power Supply | 115V | 230V |
|
|
|
ENWW | 41 |