York TCHD18 THRU 60 UC36A, UC36B, UC36C, FC/MC/PC42B, FC/MC/PC42C, FC/MC/PC43B, FC/MC/PC43C

Page 9

556454-YTG-A-0210

COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued)

UNIT

MODEL

FURNACE

MODEL

COIL

MODEL1

W

COOLING

RATEDNet MBHSEER EER

CFM TOTAL SENS.

 

 

13 SEER AC WITH VARIABLE SPEED FURNACES2

 

 

 

 

Y*9C*B12

HD36

17

635

18.5

12.9

14.75

12.35

 

Y*9C*C16

HD36

21

595

18.6

12.9

15.00

12.50

 

Y*(8,L)C*A12

UC18A

14

620

18.2

13.1

14.55

12.10

 

Y*(8,L)C*B12

UC18B

17

580

18.0

12.7

14.50

12.15

 

Y*9C*B12

UC18B

17

610

18.2

13.1

14.70

12.25

 

Y*(8,L)C*A12

UC24A

14

640

18.6

13.4

14.75

12.30

 

Y*(8,L)C*B12

UC24B

17

575

18.4

13.1

15.00

12.45

TCHD18S41S3

Y*9C*B12

UC24B

17

610

18.7

13.4

14.85

12.40

Y*(8,L)C*A12

UC30A

14

640

18.6

13.4

14.75

12.30

 

 

Y*(8,L)C*B12

UC30B

17

575

18.4

13.1

15.00

12.45

 

Y*9C*B12

UC30B

17

610

18.7

13.4

14.85

12.40

 

Y*(8,L)C*A12

UC36A

14

645

18.1

13.3

14.60

12.15

 

Y*(8,L)C*B12

UC36B

17

650

18.1

13.3

14.70

12.20

 

Y*9C*B12

UC36B

17

635

18.1

13.4

14.75

12.25

 

Y*(8,L)C*C16

UC36C

21

595

17.9

12.8

14.60

12.25

 

Y*9C*C16

UC36C

21

595

17.9

12.8

14.75

12.30

 

T*(8,L)X*A12

FC/MC/PC24A

14

775

23.4

17.3

14.50

11.75

 

T*(8,L)X*B12

FC/MC/PC24B

17

835

23.6

17.7

14.50

12.00

 

T*9X*B12

FC/MC/PC24B

17

775

23.4

17.3

14.50

11.75

 

T*(8,L)X*A12

FC/MC/PC30A

14

775

23.4

17.2

14.25

11.75

 

T*(8,L)X*B12

FC/MC/PC30B

17

835

23.6

17.7

14.50

12.00

 

T*9X*B12

FC/MC/PC30B

17

775

23.4

17.2

14.25

12.00

 

T*(8,L)X*A12

FC/MC/PC32A

14

800

23.6

17.6

14.75

12.00

 

T*(8,L)X*B12

FC/MC/PC35B

17

850

23.6

17.8

14.75

12.00

 

T*(8,L)X*C16

FC/MC/PC35C

21

625

22.8

15.9

14.25

11.75

 

T*(8,L)X*C20

FC/MC/PC35C

21

885

23.6

18.1

14.75

12.00

 

T*9X*B12

FC/MC/PC35B

17

785

23.8

17.7

14.75

12.00

 

T*9X*C16

FC/MC/PC35C

21

715

23.4

16.9

14.50

12.00

 

T*9X*C20

FC/MC/PC35C

21

825

23.6

17.6

14.50

12.00

 

T*(8,L)X*A12

FC/MC/PC36A

14

815

23.6

17.7

14.50

12.00

 

T*(8,L)X*B12

FC/MC/PC36B

17

835

23.8

17.8

14.75

12.00

 

T*(8,L)X*C16

FC/MC/PC36C

21

675

23.2

16.4

14.50

11.75

 

T*9X*B12

FC/MC/PC36B

17

775

23.6

17.6

14.50

12.00

TCHD24S41S3

T*9X*C16

FC/MC/PC36C

21

770

23.8

17.4

14.75

12.25

T*9X*C20

FC/MC/PC36C

21

810

23.6

17.6

14.50

12.00

 

 

T*(8,L)X*A12

FC/MC/PC37A

14

840

24.0

18.2

14.40

12.00

 

T*(8,L)X*B12

FC/MC/PC42B

17

865

24.2

18.4

14.75

12.00

 

T*(8,L)X*C16

FC/MC/PC42C

21

725

23.6

17.0

14.50

12.00

 

T*9X*B12

FC/MC/PC42B

17

805

23.8

17.8

14.75

12.00

 

T*9X*C16

FC/MC/PC42C

21

805

23.8

17.9

15.00

12.25

 

T*9X*C20

FC/MC/PC42C

21

790

23.6

17.6

14.50

12.00

 

T*(8,L)X*B12

FC/MC/PC43B

17

865

24.0

18.5

14.70

12.25

 

T*(8,L)X*C16

FC/MC/PC43C

21

655

23.0

16.2

14.25

11.75

 

T*9X*B12

FC/MC/PC43B

17

800

24.0

18.0

14.75

12.00

 

T*9X*C16

FC/MC/PC43C

21

735

23.6

17.2

14.75

12.00

 

T*9X*C20

FC/MC/PC43C

21

790

24.0

17.8

14.50

12.00

 

T*(8,L)X*C16

FC/MC/PC48C

21

685

23.6

16.8

14.50

12.00

 

T*9X*C16

FC/MC/PC48C

21

770

24.2

17.9

15.00

12.25

 

T*9X*C20

FC/MC/PC48C

21

815

24.2

18.2

14.75

12.00

 

T*(8,L)X*A12

HD36

14

815

23.0

17.0

14.25

11.75

 

T*(8,L)X*B12

HD36

17

855

23.0

17.0

14.25

11.75

 

T*(8,L)X*C16

HD36

21

855

23.0

17.0

14.25

11.75

For notes see Page 16.

Johnson Controls Unitary Products

9

Image 9
Contents Listed TCHD18 TCHD24 TCHD30 TCHD36 TCHD48 TCHD60 ModelAV/SV48 AV/SV60 1TVM4F1 1TVM4G1 1TVM4J1 1TVM4K1Footnotes ProceduresSeer AC with AV / SV / F*FV Variable Speed Sens Seer AC with AHP / SHP / AHX / F*FPAHP24 Cooling Unit Model CFM Range Rated NET MBH SEER1 FurnaceCFM Total Sens Seer AC with Variable Speed FURNACES2 Unit Model Furnace Coil MODEL1 CoolingUC36B UC36AUC36C FC/MC/PC42BUC42B UC42CUC48C HC30 775 23.4 17.2 14.10 12.00 28.8 21.6 14.25 12.25 LX*C20 HD36 1000 28.0 20.2 14.30 12.65 UC48D FC/MC/PC48DFC/MC/PC60D FC/PC60CUC60D UC60CSound Power Ratings Entering AIR TemperatureFurnaces Coils AHP24 AHX18 AHX24 AHX30 LX*A12 HD36 LX*B12 LX*C16 9X*B12 AHP36 AHX30 AHX36 AHX42 AHX48 FC/MC/PC30 FC/MC/PC32 FC/MC/PC36 FC/MC/PC37 FC/MC/PC43YTG-A-0210 AHP36 AHX36 AHX42 AHX48 AHX60 FC/MC/PC32 FC/MC/PC35 FC/MC/PC36 FC/MC/PC37 FC/MC/PC48LX*A12 HD36 LX*B12 9X*B12 LX*C16 HD48 LX*C20 9X*C20 9X*D20 MV16C FC/MC48C MV20D FC/MC48D FC/MC60D FC/MC62D AHP/SHP60 AHX48 AHX60LX*C16 HD48 LX*C20 9X*C16 9X*C20 9X*D20 Johnson Controls Unitary Products York Drive Norman, OK

TCHD18 THRU 60 specifications

The York TCHD18 THRU 60 series is a prominent lineup in the world of commercial heating and cooling solutions, showcasing an impressive array of features, technologies, and characteristics aimed at delivering superior performance and efficiency. Designed specifically for medium to large commercial spaces, these units are engineered to provide optimal comfort while ensuring energy efficiency, making them a top choice for facility managers and building owners.

One of the standout features of the York TCHD series is its advanced scroll compressor technology. This innovative compressor design enhances reliability and promotes quieter operation, making it ideal for installations in noise-sensitive environments. Additionally, sequential operation of multiple compressors allows for precise control over the heating and cooling output, resulting in enhanced system efficiency and reduced energy consumption.

The TCHD series is also equipped with a state-of-the-art microprocessor control system. This sophisticated control technology features user-friendly interfaces, allowing for straightforward operation and easy access to system diagnostics. With built-in communication capabilities, these units can seamlessly integrate into existing building management systems (BMS), ensuring effective monitoring and control of HVAC operations.

Energy efficiency is further accentuated by the units' robust refrigerant management system, designed to optimize refrigerant flow and minimize waste. This not only enhances overall performance but also aligns with environmental standards by promoting the use of eco-friendly refrigerants.

In terms of physical design, the York TCHD series boasts a durable steel cabinet construction, providing stability and resilience in various operating conditions. The units come with high-efficiency heat exchangers that maximize thermal transfer, ensuring that energy use is minimized while comfort is maximized.

Furthermore, York offers a variety of customization options, allowing customers to tailor the size and performance characteristics of the TCHD units to meet specific needs. Options like variable-speed fans and enhanced filtration systems provide added versatility, enabling optimal air quality and comfort control.

Overall, the York TCHD18 THRU 60 series exemplifies a commitment to innovation and performance in the commercial HVAC sector. With its advanced technologies, robust design, and energy-efficient operation, this series stands out as a reliable solution for modern commercial applications, making it a smart investment for those seeking efficient heating and cooling systems.