York TCHD18 THRU 60 warranty 28.8 21.6 14.25 12.25 LX*C20

Page 12

556454-YTG-A-0210

COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued)

UNIT

MODEL

FURNACE

MODEL

COIL

MODEL1

W

COOLING

RATEDNet MBHSEER EER

CFM TOTAL SENS.

 

 

13 SEER AC WITH VARIABLE SPEED FURNACES2

 

 

 

 

T*(8,L)X*B12

FC/MC/PC43B

17

1115

28.8

21.6

14.25

12.25

 

T*(8,L)X*C20

FC/MC/PC43C

21

870

26.4

21.3

14.50

12.50

 

T*9X*B12

FC/MC/PC43B

17

1095

28.8

21.6

14.25

12.25

 

T*9X*C16

FC/MC/PC43C

21

1055

28.8

21.1

14.25

12.25

 

T*(8,L)X*C20

FC/MC/PC48C

21

890

28.8

20.9

15.50

13.50

 

T*9X*C16

FC/MC/PC48C

21

1075

29.4

22.6

15.25

13.25

 

T*(8,L)X*A12

HD36

14

1065

28.0

21.0

14.00

12.50

 

T*(8,L)X*B12

HD36

17

1065

28.0

21.0

14.00

12.50

 

T*(8,L)X*C16

HD36

21

1065

28.2

21.1

14.00

12.75

 

T*9X*B12

HD36

17

1065

28.0

21.0

14.00

12.50

 

T*(8,L)X*A12

UC30A

14

1065

28.2

21.3

14.00

12.50

 

T*(8,L)X*B12

UC30B

17

945

28.0

20.5

14.50

12.75

 

T*9X*B12

UC30B

17

1065

28.2

21.3

14.30

12.50

 

T*(8,L)X*A12

UC36A

14

995

26.8

19.5

13.50

11.75

 

T*(8,L)X*B12

UC36B

17

1065

28.2

21.3

14.50

12.50

 

T*(8,L)X*C16

UC36C

21

1075

28.4

21.3

14.75

12.75

 

T*(8,L)X*C20

UC36C

21

890

26.6

19.4

14.25

12.25

 

T*9X*B12

UC36B

17

1070

28.2

21.3

14.50

12.50

 

T*9X*C16

UC36C

21

1070

28.4

21.3

14.50

12.75

 

T*(8,L)X*B12

UC42B

17

1025

27.2

20.3

13.75

12.00

 

T*(8,L)X*C16

UC42C

21

825

26.0

18.2

14.25

12.25

 

T*(8,L)X*C20

UC42C

21

950

27.0

19.5

14.50

12.50

 

T*9X*B12

UC42B

17

1025

27.2

20.3

13.75

12.00

 

T*9X*C16

UC42C

21

1030

27.4

20.3

14.00

12.25

 

T*(8,L)X*C16

UC48C

21

815

26.4

18.9

14.50

12.50

 

T*(8,L)X*C20

UC48C

21

960

27.4

20.1

14.75

12.75

TCHD30S41S3

T*9X*C16

UC48C

21

1035

27.6

20.7

14.25

12.25

Y*(8,L)C*A12

FC/MC/PC30A

14

1055

28.2

21.4

14.05

12.40

 

 

Y*(8,L)C*B12

FC/MC/PC30B

17

955

28.2

21.0

15.00

13.15

 

Y*9C*B12

FC/MC/PC30B

17

1050

28.2

21.2

14.50

12.75

 

Y*(8,L)C*A12

FC/MC/PC32A

14

1045

28.0

21.0

13.65

12.10

 

Y*(8,L)C*B12

FC/MC/PC35B

17

995

28.4

21.2

14.50

13.00

 

Y*9C*B12

FC/MC/PC35B

17

1045

28.2

21.6

14.25

12.50

 

Y*(8,L)C*C16

FC/MC/PC35C

21

1025

28.4

21.4

15.00

13.15

 

Y*(8,L)C*C20

FC/MC/PC35C

21

1080

28.8

22.2

15.05

13.20

 

Y*9C*C16

FC/MC/PC35C

21

1005

28.4

21.4

15.00

13.10

 

Y*9C*C20

FC/MC/PC35C

21

985

28.4

21.4

15.00

13.10

 

Y*(8,L)C*A12

FC/MC/PC36A

14

1000

28.2

21.0

14.50

12.75

 

Y*(8,L)C*B12

FC/MC/PC36B

17

985

28.4

21.0

14.80

13.05

 

Y*9C*B12

FC/MC/PC36B

17

985

28.4

21.0

14.70

13.00

 

Y*(8,L)C*C16

FC/MC/PC36C

21

1020

28.4

21.2

15.00

13.15

 

Y*(8,L)C*C20

FC/MC/PC36C

21

1055

28.8

21.8

15.20

13.35

 

Y*9C*C16

FC/MC/PC36C

21

1005

28.4

21.2

15.00

13.20

 

Y*9C*C20

FC/MC/PC36C

21

1045

28.4

21.0

14.75

13.05

 

Y*(8,L)C*A12

FC/MC/PC37A

14

980

28.8

21.6

14.50

12.80

 

Y*(8,L)C*B12

FC/MC/PC43B

17

990

28.8

21.8

15.00

13.20

 

Y*9C*B12

FC/MC/PC43B

17

1035

28.8

21.6

14.50

12.85

 

Y*(8,L)C*C16

FC/MC/PC43C

21

990

29.0

21.8

15.35

13.60

 

Y*(8,L)C*C20

FC/MC/PC43C

21

1000

29.0

21.8

15.40

13.65

 

Y*9C*C16

FC/MC/PC43C

21

1030

28.8

21.6

14.80

13.15

 

Y*9C*C20

FC/MC/PC43C

21

995

29.0

21.8

15.20

13.45

 

Y*(8,L)C*A12

HC30

14

1030

27.6

20.6

13.50

12.00

 

Y*(8,L)C*B12

HC36

17

995

28.4

21.2

14.50

13.00

 

Y*9C*B12

HC36

17

1045

28.2

21.6

14.30

12.50

For notes see Page 16.

12

Johnson Controls Unitary Products

Image 12
Contents Listed Model TCHD18 TCHD24 TCHD30 TCHD36 TCHD48 TCHD601TVM4F1 1TVM4G1 1TVM4J1 1TVM4K1 AV/SV48 AV/SV60Procedures FootnotesSeer AC with AV / SV / F*FV Variable Speed Sens Seer AC with AHP / SHP / AHX / F*FPAHP24 Furnace Cooling Unit Model CFM Range Rated NET MBH SEER1Unit Model Furnace Coil MODEL1 Cooling CFM Total Sens Seer AC with Variable Speed FURNACES2UC36A UC36BUC36C FC/MC/PC42BUC42B UC42CUC48C HC30 775 23.4 17.2 14.10 12.00 28.8 21.6 14.25 12.25 LX*C20 HD36 1000 28.0 20.2 14.30 12.65 FC/MC/PC48D UC48DFC/PC60C FC/MC/PC60DUC60C UC60DSound Power Ratings Temperature Entering AIRFurnaces Coils AHP24 AHX18 AHX24 AHX30 LX*A12 HD36 LX*B12 LX*C16 9X*B12 FC/MC/PC30 FC/MC/PC32 FC/MC/PC36 FC/MC/PC37 FC/MC/PC43 AHP36 AHX30 AHX36 AHX42 AHX48YTG-A-0210 FC/MC/PC32 FC/MC/PC35 FC/MC/PC36 FC/MC/PC37 FC/MC/PC48 AHP36 AHX36 AHX42 AHX48 AHX60LX*A12 HD36 LX*B12 9X*B12 LX*C16 HD48 LX*C20 9X*C20 9X*D20 AHP/SHP60 AHX48 AHX60 MV16C FC/MC48C MV20D FC/MC48D FC/MC60D FC/MC62DLX*C16 HD48 LX*C20 9X*C16 9X*C20 9X*D20 Johnson Controls Unitary Products York Drive Norman, OK

TCHD18 THRU 60 specifications

The York TCHD18 THRU 60 series is a prominent lineup in the world of commercial heating and cooling solutions, showcasing an impressive array of features, technologies, and characteristics aimed at delivering superior performance and efficiency. Designed specifically for medium to large commercial spaces, these units are engineered to provide optimal comfort while ensuring energy efficiency, making them a top choice for facility managers and building owners.

One of the standout features of the York TCHD series is its advanced scroll compressor technology. This innovative compressor design enhances reliability and promotes quieter operation, making it ideal for installations in noise-sensitive environments. Additionally, sequential operation of multiple compressors allows for precise control over the heating and cooling output, resulting in enhanced system efficiency and reduced energy consumption.

The TCHD series is also equipped with a state-of-the-art microprocessor control system. This sophisticated control technology features user-friendly interfaces, allowing for straightforward operation and easy access to system diagnostics. With built-in communication capabilities, these units can seamlessly integrate into existing building management systems (BMS), ensuring effective monitoring and control of HVAC operations.

Energy efficiency is further accentuated by the units' robust refrigerant management system, designed to optimize refrigerant flow and minimize waste. This not only enhances overall performance but also aligns with environmental standards by promoting the use of eco-friendly refrigerants.

In terms of physical design, the York TCHD series boasts a durable steel cabinet construction, providing stability and resilience in various operating conditions. The units come with high-efficiency heat exchangers that maximize thermal transfer, ensuring that energy use is minimized while comfort is maximized.

Furthermore, York offers a variety of customization options, allowing customers to tailor the size and performance characteristics of the TCHD units to meet specific needs. Options like variable-speed fans and enhanced filtration systems provide added versatility, enabling optimal air quality and comfort control.

Overall, the York TCHD18 THRU 60 series exemplifies a commitment to innovation and performance in the commercial HVAC sector. With its advanced technologies, robust design, and energy-efficient operation, this series stands out as a reliable solution for modern commercial applications, making it a smart investment for those seeking efficient heating and cooling systems.