Philips DVD963SA manual Error Error text Code, Basic Engine Nuclei Error Code Error text

Models: DVD963SA

1 82
Download 82 pages 58.32 Kb
Page 21
Image 21

Diagnostic Software, Trouble Shooting and Test Instructions

DVD963SA

 

5.

 

EN 35

Error

Error text

code

 

 

 

8060

DAC Mode DSD OK

 

 

8061

DAC Mode DSD I2C bus busy

 

 

8062

DAC Mode DSD I2C failed

 

 

8100

DAC Low Power Standby On OK

 

 

8101

DAC Low Power Standby On I2C bus busy

 

 

8102

DAC Low Power Standby On I2C failed

 

 

8120

DAC Low Power Standby Off OK

 

 

8121

DAC Low Power Standby Off I2C bus busy

 

 

8122

DAC Low Power Standby Off I2C failed

 

 

8200

DAC Upsample 192k OK

 

 

8201

DAC Upsample 192k I2C bus busy

 

 

8202

DAC Upsample 192k I2C failed

 

 

8220

DAC Upsample 96k OK

 

 

8221

DAC Upsample 96k I2C bus busy

 

 

8222

DAC Upsample 96k I2C failed

 

 

8240

DAC UpSample On OK

 

 

8241

DAC UpSample On bus busy

 

 

8242

DAC UpSample On I2C failed

 

 

8260

DAC UpSample Off OK

 

 

8261

DAC UpSample Off bus busy

 

 

8262

DAC UpSample Off I2C failed

 

 

5.8.2Basic Engine Nuclei

Error

 

code

Error text

 

 

3900

Test successful

 

 

3901

“Parity error from Basic Engine to Serial”

 

 

3902

“Unexpected response from Basic Engine”

 

 

3903

“Communication time-out error”

 

 

3904

“Basic Engine returned error number 0xXX”

 

 

3921

“Parity error from Basic Engine to Serial”

 

 

3922

“Unexpected response from Basic Engine”

 

 

3923

“Communication time-out error”

 

 

3924

“Basic Engine returned error number 0xXX”

 

 

 

 

3800

Test successful

 

 

3801

“Parity error from Basic Engine to Serial”

 

 

3802

“Unexpected response from Basic Engine”

 

 

3803

“Communication time-out error”

 

 

3804

“Basic Engine returned error number 0xXX”

 

 

3805

“Focus loop could not be closed”

 

 

3820

Test successful

 

 

3821

“Parity error from Basic Engine to Serial”

 

 

3822

“Unexpected response from Basic Engine”

 

 

3823

“Communication time-out error”

 

 

3824

“Basic Engine returned error number 0xXX”

 

 

 

 

4200

Test successful

 

 

4201

“Parity error from Basic Engine to Serial”

 

 

4202

“Unexpected response from Basic Engine”

 

 

4203

“Communication time-out error”

 

 

4204

“Basic Engine returned error number 0xXX”

 

 

4205

“Sledge could not be moved to home

 

position”

 

 

4206

“Focus loop could not be closed”

 

 

4207

“Motor not on speed within time-out”

 

 

4208

“Radial loop could not be closed”

 

 

4209

“PLL could not lock in accessing or tracking

 

state”

 

 

Error

 

code

Error text

 

 

4210

“Subcode or sector information could not be

 

read”

 

 

4211

“Requested subcode item could not be

 

found”

 

 

4212

“TOC could not be read in time”

 

 

4213

“Seek could not be performed”

 

 

4220

Test successful

 

 

4221

“Parity error from Basic Engine to Serial”

 

 

4222

“Unexpected response from Basic Engine”

 

 

4223

“Communication time-out error”

 

 

4224

“Basic Engine returned error number 0xXX”

 

 

4225

“Sledge could not be moved to home

 

position”

 

 

4226

“Focus loop could not be closed”

 

 

4227

“Motor not on speed within time-out”

 

 

4228

“Radial loop could not be closed”

 

 

4229

“PLL could not lock in accessing or tracking

 

state”

 

 

4230

“Subcode or sector information could not be

 

read”

 

 

4231

“Requested subcode item could not be

 

found”

 

 

4232

“TOC could not be read in time”

 

 

4233

“Seek could not be performed”

 

 

4240

Test successful

 

 

4241

“Parity error from Basic Engine to Serial”

 

 

4242

“Unexpected response from Basic Engine”

 

 

4243

“Communication time-out error”

 

 

4244

“Basic Engine returned error number 0xXX”

 

 

4245

“Sledge could not be moved to home

 

position”

 

 

4246

“Focus loop could not be closed”

 

 

4247

“Motor not on speed within time-out”

 

 

4248

“Radial loop could not be closed”

 

 

4249

“PLL could not lock in accessing or tracking

 

state”

 

 

4250

“Subcode or sector information could not be

 

read”

 

 

4251

“Requested subcode item could not be

 

found”

 

 

4252

“TOC could not be read in time”

 

 

4253

“Seek could not be performed”

 

 

 

 

4000

Test successful

 

 

4001

“Parity error from Basic Engine to Serial”

 

 

4002

“Unexpected response from Basic Engine”

 

 

4003

“Communication time-out error”

 

 

4004

“Basic Engine returned error number 0xXX”

 

 

4005

“Radial loop could not be closed”

 

 

4020

Test successful

 

 

4021

“Parity error from Basic Engine to Serial”

 

 

4022

“Unexpected response from Basic Engine”

 

 

4023

“Communication time-out error”

 

 

4024

“Basic Engine returned error number 0xXX”

 

 

 

 

4400

Test successful

 

 

4401

Test successful

 

 

 

 

4100

Test successful

 

 

4101

“Parity error from Basic Engine to Serial”

 

 

4102

“Unexpected response from Basic Engine”

 

 

4103

“Communication time-out error”

 

 

Page 21