Philips DVD963SA manual SMA Error Codes, Reprogramming of New Mono Boards

Models: DVD963SA

1 82
Download 82 pages 58.32 Kb
Page 15
Image 15

Diagnostic Software, Trouble Shooting and Test Instructions

DVD963SA

 

5.

 

EN 29

Error

 

 

Code

Error name

Explanation

 

 

 

0008

SP_CONTINU

Sequence of sectors coming

 

ITYERROR

from disc is incorrect. Reason:

 

 

see SP_SYNCERROR

 

 

 

0009

DMX_CONTI

Sequence of sectors is incorrect.

 

NUITYERRO

Reason: problem with buffer

 

R

RAM

 

 

 

000A

LLD_ERROR

An illegal audio format was

 

 

offered to the decoder. Reason:

 

 

unknown audio type on disc or

 

 

problem with buffer RAM

 

 

 

000B

BCU_ERROR

Internal problem in Furore chip

 

 

 

SMA Error Codes

Error

 

 

Number

Error name

Explanation

 

 

 

0000

SMA_TIMEO

Data coming from disc not in

 

UTERROR

time. Reason: damaged disc or

 

 

engine problem.

 

 

 

5.6.2Reprogramming of New Mono Boards.

Caution

This information is confidential and may not be distributed. Only a qualified service person should reprogram the mono board.

After reset of NV-memory or repair of the mono board, all the customer settings and also the region code will be lost.

Reprogramming of the mono board will put the player back in the state in which it has left the factory, i.e. with the default settings and the allowed region code.

Reprogramming is limited to 25 times

When the counter reaches 25, reprogramming is not possible anymore Reprogramming will be done by way of the remote control.

Put the player in stop mode, no disc loaded. Press the following keys on the remote control: <PLAY> followed by numerical keys <1> <5> <9> The display shows: “- - - - - - - - - - -

Press now successively the following keys :

for DVD963SA /001 : <2><2><2> <0><1><2><0><0>

for DVD963SA 171 : <1><1><1> <0><1><0><0><0>

for DVD963SA 691 : <3><2><3> <0><1><0><0><0>

Press <PLAY> again.

The TV screen will become BLUE during a short time to confirm that the mono board has been reprogrammed.

CL 26532105_053.eps 280802