York YCJD18 THRU 60 warranty UC60D

Page 13

840569-YTG-A-0612

COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued)

UNIT

MODEL

FURNACE

MODEL

WIDTH

 

 

COIL

MODEL1

COOLING

RATED NET MBH SEER EER

CFM TOTAL SENS.

13 SEER AC WITH HIGH EFFICIENCY MOTOR FURNACES2

YCJD42S41S2(H)(E)

For notes see Page 15.

T*9(C,V)*C20

21.0

FC64D

1445

42.0

30.8

13.75

11.75

T*9(C,V)*C20

21.0

UC48C

1430

42.0

30.2

13.25

11.25

T*9(C,V)*C20

21.0

UC60C

1445

41.5

29.8

13.00

11.25

T*9(C,V)*D20

24.5

FC/MC/PC48D

1450

42.0

30.2

13.50

11.50

T*9(C,V)*D20

24.5

FC/MC/PC60D

1445

42.0

30.0

13.50

11.50

T*9(C,V)*D20

24.5

FC/MC62D

1455

42.0

30.6

13.50

11.50

T*9(C,V)*D20

24.5

FC64D

1455

42.0

30.6

14.00

11.75

T*9(C,V)*D20

24.5

UC48D

1450

42.0

30.2

13.50

11.50

T*9(C,V)*D20

24.5

UC60D

1445

41.5

29.8

13.25

11.25

T*9X*B12

17.5

FC/MC/PC43B

1270

41.5

29.0

13.50

11.50

T*9X*C16

21.0

FC/MC/PC43C

1410

42.0

30.2

13.75

11.50

T*9X*C16

21.0

FC/MC/PC48C

1425

42.0

30.4

13.75

11.75

T*9X*C16

21.0

FC/MC/PC48D

1425

42.0

30.4

13.75

11.75

T*9X*C16

21.0

FC/MC/PC60D

1460

42.0

30.0

13.75

11.50

T*9X*C16

21.0

FC/MC62D

1460

42.0

30.6

13.75

11.75

T*9X*C16

21.0

FC/PC60C

1460

42.0

30.0

13.75

11.50

T*9X*C16

21.0

FC64D

1460

42.0

30.8

14.25

12.00

T*9X*C16

21.0

UC48C

1425

42.0

30.4

13.75

11.75

T*9X*C16

21.0

UC60C

1460

42.0

30.0

13.50

11.50

T*9X*C20

21.0

FC/MC/PC43C

1400

42.0

30.4

14.00

11.75

T*9X*C20

21.0

FC/MC/PC48C

1420

42.0

30.4

14.00

11.75

T*9X*C20

21.0

FC/MC/PC48D

1420

42.0

30.4

14.00

11.75

T*9X*C20

21.0

FC/MC/PC60D

1460

42.0

30.2

13.75

11.75

T*9X*C20

21.0

FC/MC62D

1460

42.0

30.8

14.00

11.75

T*9X*C20

21.0

FC/PC60C

1460

42.0

30.2

13.75

11.75

T*9X*C20

21.0

FC64D

1460

42.0

30.8

14.50

12.25

T*9X*C20

21.0

UC48C

1420

42.0

30.4

14.00

11.75

T*9X*C20

21.0

UC60C

1460

42.0

30.0

13.75

11.75

T*9X*D20

24.5

FC/MC/PC48D

1435

42.0

30.4

14.00

12.00

T*9X*D20

24.5

FC/MC/PC60D

1515

42.0

31.0

14.00

12.00

T*9X*D20

24.5

FC/MC62D

1425

42.0

30.8

14.00

12.00

T*9X*D20

24.5

FC64D

1425

42.0

30.8

14.50

12.25

T*9X*D20

24.5

UC48D

1435

42.0

30.0

14.00

12.00

T*9X*D20

24.5

UC60D

1515

42.0

31.4

13.75

12.00

Y*(8,L)C*B12

17.5

FC/MC/PC43B

1270

41.0

28.8

13.25

11.25

Y*(8,L)C*C16

21.0

FC/MC/PC43C

1390

42.0

30.2

13.50

11.50

Y*(8,L)C*C16

21.0

FC/MC/PC48C

1330

42.0

29.8

13.50

11.50

Y*(8,L)C*C16

21.0

FC/MC/PC48D

1330

42.0

29.8

13.50

11.50

Y*(8,L)C*C16

21.0

FC/MC/PC60D

1420

42.0

30.0

13.50

11.50

Y*(8,L)C*C16

21.0

FC/MC62D

1420

42.0

30.6

13.50

11.50

Y*(8,L)C*C16

21.0

FC/PC60C

1420

42.0

30.0

13.50

11.50

Y*(8,L)C*C16

21.0

FC64D

1420

42.0

30.8

14.25

12.00

Y*(8,L)C*C16

21.0

UC48C

1435

42.0

30.2

13.50

11.50

Y*(8,L)C*C16

21.0

UC60C

1420

42.0

30.0

13.50

11.50

Y*(8,L)C*C20

21.0

FC/MC/PC43C

1450

42.0

30.6

13.25

11.25

Y*(8,L)C*C20

21.0

FC/MC/PC48C

1410

42.0

30.2

13.75

11.50

Y*(8,L)C*C20

21.0

FC/MC/PC48D

1410

42.0

30.2

13.75

11.50

Y*(8,L)C*C20

21.0

FC/MC/PC60D

1340

42.0

30.2

13.75

11.75

Y*(8,L)C*C20

21.0

FC/MC62D

1365

42.0

30.8

14.00

11.75

Y*(8,L)C*C20

21.0

FC/PC60C

1340

42.0

30.2

13.75

11.75

Y*(8,L)C*C20

21.0

FC64D

1410

42.0

30.8

14.25

12.00

Y*(8,L)C*C20

21.0

UC48C

1410

42.0

30.2

13.75

11.75

Johnson Controls Unitary Products

13

Image 13
Contents Technical Guide Model Physical and Electrical DataSystem Charge for Various Matched Systems Footnotes ProceduresCooling Model Width MODEL1 Rated NET MBH Seer EER CFM Unit AIR HandlerSens Seer AC with AIR HandlersMV12D 24.5 1600 Seer AC Coil only Ratings Coil CFM Range Cooling Unit Model Rated NET MBH Seer WidthCooling Capacity With High Efficiency Motor Furnaces FC/MC/PC43C FC/MC/PC48C FC/MC/PC60D UC60D 1410 42.0 30.0 13.50 11.50 9C*C16 21.0 9C*C20 21.0 Sound Power Ratings AIR Conditioner Model no TemperatureIndoor Coil Model no FC/MC/PC18 Condensing Idcfm Entering AIRIndoor Coil Model no FC/MC/PC36 Condensing FC/MC/PC32A Indoor Coil Model no FC/MC/PC32 Condensing FC/MC/PC43C Indoor Coil Model no FC/MC/PC37 Condensing FC/MC/PC48C Indoor Coil Model no FC/MC/PC43 Condensing UC60D Indoor Coil Model no FC/MC/PC48 Condensing Indoor Coil Model no FC/MC/PC60 Condensing Idcfm York International Corp York Drive Norman, OK
Related manuals
Manual 18 pages 57.82 Kb

YCJD18 THRU 60 specifications

The York YCJD18 THRU 60 is a dynamic heating, ventilation, and air conditioning (HVAC) system that incorporates advanced technology and design principles to deliver efficient climate control in commercial spaces. As part of York's heritage in the HVAC industry, this unit is engineered to meet diverse cooling and heating demands while maintaining high energy efficiency standards.

One of the main features of the YCJD series is its capacity range, which extends from 18 to 60 tons. This versatility makes it suitable for a variety of commercial applications, including office buildings, retail spaces, and educational institutions. The system utilizes a scroll compressor, known for its durability and quiet operation, ensuring that occupants experience minimal noise disruption during operation.

In terms of energy efficiency, the YCJD18 THRU 60 boasts high Seasonal Energy Efficiency Ratio (SEER) and Energy Efficiency Ratio (EER) ratings. These ratings indicate that the unit is well-equipped to handle cooling loads while consuming less energy compared to traditional HVAC systems. This not only translates to lower operational costs but also aligns with global initiatives towards sustainability and reducing carbon footprints.

The YCJD series incorporates advanced controls and monitoring technologies, allowing for precise adjustments and diagnostics. The integration of smart controls enables users to optimize system performance, schedule operations, and monitor energy usage from a remote interface. This feature enhances user experience while providing valuable insights into system efficiency and maintenance needs.

Another notable characteristic of the YCJD is its robust construction designed to withstand the rigors of various climates. The unit is typically equipped with high-quality insulation, weatherproof housing, and corrosion-resistant components, contributing to its longevity and reliability in different environments.

The installation flexibility is another strong point for the YCJD series, as it offers options for rooftop or ground-level placement. This adaptability makes it easy for HVAC professionals to customize installations to fit existing structures or new builds.

In summary, the York YCJD18 THRU 60 is a comprehensive HVAC solution designed for commercial use, featuring high energy efficiency, advanced control technologies, and robust construction. Its wide capacity range and installation versatility make it a reliable choice for maintaining comfortable indoor environments across diverse applications. With York's commitment to innovation, the YCJD series represents a significant step forward in HVAC technology, ensuring users benefit from enhanced performance and sustainability.