York YCJD18 THRU 60 warranty Physical and Electrical Data, Model

Page 2

840569-YTG-A-0612

Physical and Electrical Data

MODEL

 

YCJD18

YCJD24

YCJD30

YCJD36

YCJD42

YCJD48

YCJD60

 

S41S1(H)(E)

S41S1(H)(E)

S41S1(H)(E)

S41S1(H)(E)

S41S2(H)(E)

S41S1(H)(E)

S41S1(E)

 

 

 

 

 

 

 

 

 

 

 

Unit Supply Voltage

 

 

 

208-230V, 1φ, 60Hz

 

 

Normal Voltage Range 1

 

 

 

187 to 252

 

 

 

Minimum Circuit Ampacity

10.0

12.4

14.7

17.9

21.5

21.1

34.3

Max. Overcurrent Device Amps 2

15

20

25

30

35

35

60

Min. Overcurrent Device Amps 3

15

15

15

20

25

25

35

Compressor Type

 

Rotary

Recip

Recip

Recip

Recip

Recip

Scroll

 

 

 

 

 

 

 

 

 

Compressor Amps

Rated Load

7.6

9.3

10.6

13.1

16

15.7

26.2

Locked Rotor

40

43

54

74

88

84

150

 

 

 

 

 

 

 

 

 

 

Crankcase Heater

 

No

No

No

No

No

No

No

 

 

 

 

 

 

 

 

Factory External Discharge Muffler

No

No

No

No

No

Yes

No

 

 

 

 

 

 

 

 

Factory External Check Valve

No

No

No

No

No

No

No

 

 

 

 

 

 

 

 

HS Kit Required with TXV 4

Yes

Yes

Yes

Yes

Yes

Yes

No

Fan Motor Amps

Rated Load

0.5

0.8

1.4

1.5

1.5

1.5

1.5

Fan Diameter Inches

 

17.5

17.5

17.5

22.0

22.0

22.0

24.0

 

Rated HP

1/12

1/8

1/4

1/4

1/4

1/4

1/4

Fan Motor

Nominal RPM

1100

1075

1100

850

850

850

850

 

Nominal CFM

1400

1950

2050

3200

3050

2950

3600

 

Face Area Sq. Ft.

9.60

9.60

9.60

13.07

14.16

14.16

18.68

Coil

Rows Deep

1

1

1

1

1

1

1

 

Fin / Inches

23

23

23

23

23

23

23

Liquid Line Set OD

(Field Installed)

3/8

3/8

3/8

3/8

3/8

3/8

3/8

Vapor Line Set OD (Field Installed)

5/8

3/4

3/4

3/4

7/8

7/8

7/8

Unit Charge (Lbs. - Oz.) 5

3 - 3

3 - 13

3 - 14

4 - 9

4 - 10

4 - 9

5 - 6

Charge Per Foot, Oz.

0.58

0.62

0.62

0.62

0.67

0.67

0.67

 

 

 

 

 

 

 

 

Operating Weight Lbs.

97

129

131

145

164

173

195

Models with "H" on the end of the model number are shipped with a Hard Start Kit installed at the factory. Models with “E” on the end of the model number have an ElectroFin® coating on the outdoor coil.

1.Rated in accordance with AHRI Standard 110-2012, utilization range “A”.

2.Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.

3.Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.

4.See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.

5.The Unit Charge is correct for the outdoor unit, smallest matched indoor unit, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.

C

A

B

2

All dimensions are in inches. They are subject to change with- out notice. Certified dimensions will be provided upon request.

Unit

 

Dimensions

 

Refrigerant Connection

 

 

(Inches)

 

Service Valve Size

Model

 

 

 

 

 

 

 

A1

 

B

 

C

Liquid

Vapor

 

 

 

18

28

 

23-1/2

 

23-1/2

 

 

 

 

 

 

 

 

 

 

24

28

 

23-1/2

 

23-1/2

 

3/4”

 

 

 

 

 

 

 

30

28

 

23-1/2

 

23-1/2

 

 

 

 

 

 

 

 

 

 

 

3/8”

 

36

28

 

29

 

29

 

 

 

 

 

 

 

 

 

42

30

 

29

 

29

 

 

 

 

 

 

 

 

 

7/8”

48

30

 

29

 

29

 

 

 

 

 

 

 

 

 

60

32

 

33-5/8

 

33-5/8

 

 

 

 

 

 

 

 

 

 

1. Overall height from bottom of base pan to top of fan guard.

Johnson Controls Unitary Products

Image 2
Contents Technical Guide Physical and Electrical Data ModelSystem Charge for Various Matched Systems Procedures FootnotesSens Unit AIR HandlerCooling Model Width MODEL1 Rated NET MBH Seer EER CFM Seer AC with AIR HandlersMV12D 24.5 1600 Coil CFM Range Cooling Unit Model Rated NET MBH Seer Width Seer AC Coil only RatingsCooling Capacity With High Efficiency Motor Furnaces FC/MC/PC43C FC/MC/PC48C FC/MC/PC60D UC60D 1410 42.0 30.0 13.50 11.50 9C*C16 21.0 9C*C20 21.0 Sound Power Ratings Indoor Coil Model no FC/MC/PC18 Condensing Idcfm TemperatureAIR Conditioner Model no Entering AIRIndoor Coil Model no FC/MC/PC36 Condensing FC/MC/PC32A Indoor Coil Model no FC/MC/PC32 Condensing FC/MC/PC43C Indoor Coil Model no FC/MC/PC37 Condensing FC/MC/PC48C Indoor Coil Model no FC/MC/PC43 Condensing UC60D Indoor Coil Model no FC/MC/PC48 Condensing Indoor Coil Model no FC/MC/PC60 Condensing Idcfm York International Corp York Drive Norman, OK
Related manuals
Manual 18 pages 57.82 Kb

YCJD18 THRU 60 specifications

The York YCJD18 THRU 60 is a dynamic heating, ventilation, and air conditioning (HVAC) system that incorporates advanced technology and design principles to deliver efficient climate control in commercial spaces. As part of York's heritage in the HVAC industry, this unit is engineered to meet diverse cooling and heating demands while maintaining high energy efficiency standards.

One of the main features of the YCJD series is its capacity range, which extends from 18 to 60 tons. This versatility makes it suitable for a variety of commercial applications, including office buildings, retail spaces, and educational institutions. The system utilizes a scroll compressor, known for its durability and quiet operation, ensuring that occupants experience minimal noise disruption during operation.

In terms of energy efficiency, the YCJD18 THRU 60 boasts high Seasonal Energy Efficiency Ratio (SEER) and Energy Efficiency Ratio (EER) ratings. These ratings indicate that the unit is well-equipped to handle cooling loads while consuming less energy compared to traditional HVAC systems. This not only translates to lower operational costs but also aligns with global initiatives towards sustainability and reducing carbon footprints.

The YCJD series incorporates advanced controls and monitoring technologies, allowing for precise adjustments and diagnostics. The integration of smart controls enables users to optimize system performance, schedule operations, and monitor energy usage from a remote interface. This feature enhances user experience while providing valuable insights into system efficiency and maintenance needs.

Another notable characteristic of the YCJD is its robust construction designed to withstand the rigors of various climates. The unit is typically equipped with high-quality insulation, weatherproof housing, and corrosion-resistant components, contributing to its longevity and reliability in different environments.

The installation flexibility is another strong point for the YCJD series, as it offers options for rooftop or ground-level placement. This adaptability makes it easy for HVAC professionals to customize installations to fit existing structures or new builds.

In summary, the York YCJD18 THRU 60 is a comprehensive HVAC solution designed for commercial use, featuring high energy efficiency, advanced control technologies, and robust construction. Its wide capacity range and installation versatility make it a reliable choice for maintaining comfortable indoor environments across diverse applications. With York's commitment to innovation, the YCJD series represents a significant step forward in HVAC technology, ensuring users benefit from enhanced performance and sustainability.