York TCGD12 THRU 60 warranty FC/MC/PC/UC24, AHP18 AHP24, MA08B FC/MC18B FC/MC24B MV12B

Page 12

400034-YTG-B-0708

COOLING PERFORMANCE DATA

AIR CONDITIONER MODEL NO.

TCGD18S21S2(H)

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

 

FC/MC/PC18

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSING

IDCFM

 

 

 

450

 

 

 

 

600

 

 

 

 

750

 

 

ENTERING AIR

ID DB (°F)

80

80

 

75

80

80

80

80

75

80

80

80

80

75

80

80

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

57

62

 

62

67

72

57

62

62

67

72

57

62

62

67

72

 

T.C.

15.4

17.1

 

16.7

18.1

18.0

16.2

17.6

17.2

18.2

18.0

17.0

18.2

17.6

18.3

18.0

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

15.2

13.4

 

11.4

11.3

8.6

16.0

14.7

12.6

12.0

9.0

16.8

16.0

13.8

12.7

9.5

 

KW

1.0

1.0

 

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

 

T.C.

14.9

16.6

 

16.3

17.7

18.0

15.9

17.3

16.8

17.9

18.1

16.9

18.0

17.3

18.2

18.2

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

14.7

13.4

 

11.3

11.1

8.5

15.7

14.9

12.7

12.1

9.2

16.7

16.4

14.1

13.1

9.8

 

KW

1.1

1.1

 

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

 

T.C.

14.4

16.1

 

15.8

17.3

18.0

15.6

17.0

16.3

17.7

18.2

16.8

17.8

16.9

18.1

18.4

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

14.3

13.5

 

11.2

11.0

8.5

15.5

15.2

12.8

12.3

9.3

16.6

16.9

14.4

13.6

10.2

 

KW

1.2

1.2

 

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

 

T.C.

13.9

15.7

 

15.4

16.8

17.9

15.3

16.6

15.9

17.4

18.2

16.7

17.5

16.5

18.0

18.5

95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

13.8

13.5

 

11.1

10.8

8.5

15.2

15.4

12.9

12.4

9.5

16.5

17.3

14.7

14.0

10.5

 

KW

1.3

1.3

 

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

 

T.C.

13.2

14.6

 

14.2

15.9

17.2

14.6

15.7

14.9

16.5

17.5

16.0

16.8

15.5

17.1

17.8

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

13.1

13.1

 

10.6

10.6

8.3

14.4

14.8

12.4

12.3

9.3

15.8

16.4

14.2

13.9

10.4

 

KW

1.5

1.5

 

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

 

T.C.

12.5

13.6

 

13.1

15.0

16.5

13.9

14.9

13.8

15.6

16.8

15.2

16.2

14.6

16.2

17.2

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

12.4

12.6

 

10.1

10.3

8.1

13.7

14.1

11.9

12.1

9.2

15.1

15.7

13.7

13.8

10.2

 

KW

1.6

1.6

 

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

 

T.C.

11.8

12.6

 

12.0

14.2

15.7

13.2

14.1

12.8

14.8

16.1

14.5

15.5

13.6

15.3

16.5

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

11.7

12.2

 

9.6

10.1

7.9

13.0

13.5

11.5

11.9

9.0

14.4

14.9

13.3

13.8

10.1

 

KW

1.7

1.7

 

1.7

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

Air Handler

Coil

T.C.

S.C.

KW

FC/MC/PC/UC24

1.00

1.00

1.00

HC18

1.00

1.00

1.00

UC18

1.00

1.00

1.00

AHP18

1.00

1.00

1.00

AHP24

1.00

1.00

1.00

AV24

1.00

1.03

0.91

F4FP024

1.00

1.00

1.00

MA08B

FC/MC18B

1.00

1.00

1.00

MA08B

FC/MC24B

1.00

1.00

1.00

MV12B

FC/MC18B

1.00

1.03

0.91

MV12B

FC/MC24B

1.00

1.03

0.91

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

PV8*A12

FC/MC/PC18A

1.00

1.03

0.91

PV9*A12

FC/MC/PC18A

1.00

1.02

0.91

P(C,V)9*B12

FC/MC/PC18B

1.00

1.03

0.91

PV8*A12

FC/MC/PC24A

1.00

1.03

0.91

PV9*A12

FC/MC/PC24A

1.00

1.02

0.91

P(C,V)9*B12

FC/MC/PC24B

1.00

1.03

0.91

PV8*A12

HC18

1.00

1.03

0.91

PV9*A12

HC18

1.00

1.02

0.91

12

Johnson Controls Unitary Products

Image 12
Contents Warranty FeaturesDescription Model TCGD12 TCGD18 TCGD24 TCGD30 TCGD36 TCGD42 TCGD48 TCGD60AHP18B2A AHP24B2A AHP30B2A AHP36C2A AHP42C2C AHP/SHP60D2C AV24B2A AV36C2AAV/SV48D2C FC/MC/PC/UC18A3X FC/MC/PC/UC18B3XProcedures FootnotesUnit Model AIR Handler Seer AC with MV Variable SpeedSeer AC with AV / SV / F*FV Variable Speed Condenser only Data Unit AIR HandlerCooling Rated NET MBH Model Seer EER CFMFC/MC/PC18 FC/MC/PC24FC/MC/PC32 FC/MC/PC35Seer AC with Variable Speed FURNACES2 FC/MC/PC48C FC/MC/PC48DAccessories Sound Power RatingsTypical Installation Typical Field WiringCooling Performance Data FC/MC/PC/UC24 AHP18 AHP24MA08B FC/MC18B FC/MC24B MV12B FC/MC/PC32 FC/MC/PC35 FC/MC/PC37 FC/MC/PC43 MA08B FC/MC35B FC/MC36B FC/MC43B MV12BFC/MC/PC32 FC/MC/PC37 FC/MC/PC43 AHP30 AHP36MA12B FC/MC35B FC/MC43B MV12B MV16C FC/MC43C FC/MC35C FC/MC/PC35AIndoor Coil Model no FC/MC/PC43 Condensing FC/MC/PC37A FC/MC/PC/UC48MA16C FC/MC43C MA14D FC/MC48D FC/MC48C MV16C MV20D Indoor Coil Model no FC/MC/PC48 Condensing AHP/SHP60 AV/SV48MA16C FC/MC48C MA20D FC/MC48D MV16C MV20D MA20D FC/MC62D MV20D