York TCGD12 THRU 60 warranty Condenser only Data, Unit AIR Handler, Cooling Rated NET MBH Model

Page 6

400034-YTG-B-0708

COOLING CAPACITY - With Air Handler Coils (Continued)

UNIT

AIR HANDLER

 

COIL

 

 

 

COOLING

 

 

 

 

 

RATED

 

NET MBH

 

 

MODEL

MODEL

 

W

MODEL1

 

SEER

EER

 

CFM

 

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

 

 

13

SEER AC WITH AHP

/ SHP / F*FP

 

 

 

 

 

TCGD12S21S2(H)

AHP18

 

17

450

 

12.0

8.9

13.00

11.00

 

AHP18

 

17

650

 

18.0

12.6

13.00

11.00

TCGD18S21S2(H)

 

 

 

 

 

 

 

 

 

 

AHP24

 

17

650

 

18.0

12.6

13.00

11.00

 

F4FP024

 

18

600

 

18.0

12.6

1300

11.00

TCGD24S21S2(H)

AHP30

 

17

795

 

24.0

17.3

13.00

11.00

F4FP036

 

21.5

860

 

24.0

17.3

13.00

11.00

 

 

 

 

AHP30

 

17

1015

 

29.0

21.2

13.00

11.00

TCGD30S21S2(H)

 

 

 

 

 

 

 

 

 

 

AHP36

 

21

1015

 

29.0

21.2

13.00

11.00

 

F4FP040

 

21.5

1000

 

29.0

21.2

13.00

11.00

TCGD36S21S2(H)

AHP36

 

21

1235

 

35.0

24.4

13.00

11.00

F5FP048

 

24

1235

 

35.0

24.4

13.00

11.00

 

 

 

TCGD42S21S2(H)

AHP42

 

21

1485

 

42.0

29.4

13.00

11.00

F5FP048

 

24

1455

 

42.0

29.4

13.00

11.00

 

 

 

 

AHP/SHP60

 

24

1600

 

46.0

33.0

13.00

11.00

TCGD48S21S2(H)

 

 

 

 

 

 

 

 

 

 

F5FP048

 

24

1690

 

46.0

33.0

13.00

11.00

 

F5FP060

 

24

1680

 

46.0

33.0

13.00

11.00

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.

1.MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

— = Not applicable.

CONDENSER ONLY DATA

 

Suct. T/P @ Compr.

 

 

 

Air Temp on Condenser

 

 

 

Model

 

75° F

 

95° F

 

115° F

 

 

 

 

 

 

Temp.

PSIG

MBH

 

KW

MBH

 

KW

MBH

 

KW

TCGD12S21S2(H)

40

68.6

11.81

 

0.73

8.15

 

0.85

5.29

 

1.01

SH 11 / SC 13 @

45

76.1

12.65

 

0.73

10.15

 

0.86

7.21

 

1.02

95 OD Temp

50

84.1

13.55

 

0.74

12.29

 

0.87

9.26

 

1.04

TCGD18S21S2(H)

40

68.6

17.53

 

1.07

15.03

 

1.29

11.98

 

1.57

SH 11 / SC 10 @

45

76.1

18.63

 

1.07

17.25

 

1.30

14.07

 

1.59

95 OD Temp

50

84.1

19.80

 

1.08

19.61

 

1.31

16.30

 

1.61

TCGD24S21S2(H)

40

68.6

22.88

 

1.42

19.07

 

1.70

13.99

 

2.02

SH 10 / SC 12 @

45

76.1

24.93

 

1.44

22.25

 

1.72

17.25

 

2.07

95 OD Temp

50

84.1

27.12

 

1.47

25.63

 

1.75

20.72

 

2.12

TCGD30S21S2(H)

40

68.6

28.77

 

1.75

23.85

 

2.01

17.06

 

2.21

SH 12 / SC 10 @

45

76.1

30.28

 

1.80

26.56

 

2.07

19.76

 

2.31

95 OD Temp

50

84.1

31.89

 

1.86

29.45

 

2.13

22.64

 

2.40

TCGD36S21S2(H)

40

68.6

31.46

 

2.16

18.41

 

2.37

13.42

 

2.78

SH 10 / SC 11 @

45

76.1

36.54

 

2.20

25.84

 

2.47

18.88

 

2.85

95 OD Temp

50

84.1

41.95

 

2.24

33.77

 

2.58

24.71

 

2.91

TCGD42S21S2(H)

40

68.6

40.44

 

2.46

28.86

 

2.83

21.78

 

3.21

SH 10 / SC 9 @ 95

45

76.1

45.28

 

2.52

36.10

 

2.91

27.55

 

3.30

OD Temp

50

84.1

50.44

 

2.59

43.82

 

3.00

33.70

 

3.41

TCGD48S21S2(H)

40

68.6

42.04

 

2.70

26.14

 

3.03

21.19

 

3.49

SH 10 / SC 12 @

45

76.1

46.86

 

2.77

35.10

 

3.16

27.59

 

3.60

95 OD Temp

50

84.1

52.00

 

2.85

44.65

 

3.30

34.43

 

3.73

TCGD60S21S2

40

68.6

52.76

 

3.40

46.38

 

4.04

36.26

 

5.08

SH 10 / SC 9 @ 95

45

76.1

59.98

 

3.41

53.35

 

4.14

42.46

 

5.15

OD Temp

50

84.1

67.69

 

3.41

60.79

 

4.25

49.07

 

5.22

6

Johnson Controls Unitary Products

Image 6
Contents Warranty FeaturesDescription Model TCGD12 TCGD18 TCGD24 TCGD30 TCGD36 TCGD42 TCGD48 TCGD60 AV/SV48D2C FC/MC/PC/UC18A3X AHP18B2A AHP24B2A AHP30B2A AHP36C2A AHP42C2C AHP/SHP60D2C AV24B2A AV36C2A FC/MC/PC/UC18B3XProcedures FootnotesUnit Model AIR Handler Seer AC with MV Variable SpeedSeer AC with AV / SV / F*FV Variable Speed Cooling Rated NET MBH Model Condenser only DataUnit AIR Handler Seer EER CFMFC/MC/PC32 FC/MC/PC18FC/MC/PC24 FC/MC/PC35Seer AC with Variable Speed FURNACES2 FC/MC/PC48C FC/MC/PC48DTypical Installation AccessoriesSound Power Ratings Typical Field WiringCooling Performance Data FC/MC/PC/UC24 AHP18 AHP24MA08B FC/MC18B FC/MC24B MV12B FC/MC/PC32 FC/MC/PC35 FC/MC/PC37 FC/MC/PC43 MA08B FC/MC35B FC/MC36B FC/MC43B MV12BMA12B FC/MC35B FC/MC43B MV12B MV16C FC/MC43C FC/MC35C FC/MC/PC32 FC/MC/PC37 FC/MC/PC43AHP30 AHP36 FC/MC/PC35AIndoor Coil Model no FC/MC/PC43 Condensing FC/MC/PC37A FC/MC/PC/UC48MA16C FC/MC43C MA14D FC/MC48D FC/MC48C MV16C MV20D Indoor Coil Model no FC/MC/PC48 Condensing AHP/SHP60 AV/SV48MA16C FC/MC48C MA20D FC/MC48D MV16C MV20D MA20D FC/MC62D MV20D