York TCGD12 THRU 60 warranty Indoor Coil Model no FC/MC/PC43 Condensing, FC/MC/PC37A FC/MC/PC/UC48

Page 15

400034-YTG-B-0708

COOLING PERFORMANCE DATA

AIR CONDITIONER MODEL NO.

TCGD36S21S2(H)

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

 

FC/MC/PC43

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSING

IDCFM

 

 

1000

 

 

 

 

1200

 

 

 

 

1400

 

 

ENTERING AIR

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

57

62

62

67

72

57

62

62

67

72

57

62

62

67

72

 

T.C.

35.6

36.1

34.4

37.6

38.5

37.2

37.4

35.5

38.5

38.9

38.9

38.6

36.7

39.4

39.2

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

32.9

29.4

24.0

23.3

17.9

34.4

31.7

25.4

24.7

18.3

35.9

34.0

26.7

26.2

18.7

 

KW

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

 

T.C.

33.6

34.4

32.7

36.1

37.2

36.0

36.0

34.0

37.1

37.6

38.3

37.6

35.2

38.2

38.0

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

31.2

29.0

23.6

23.0

17.5

33.1

31.4

25.3

24.8

18.1

35.0

33.9

27.0

26.5

18.7

 

KW

2.1

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.3

 

T.C.

31.6

32.6

31.1

34.6

35.9

34.7

34.6

32.4

35.8

36.3

37.8

36.6

33.7

37.0

36.8

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

29.6

28.6

23.2

22.8

17.1

31.9

31.2

25.3

24.8

17.9

34.2

33.8

27.3

26.8

18.7

 

KW

2.3

2.3

2.3

2.4

2.5

2.4

2.4

2.4

2.4

2.5

2.4

2.4

2.4

2.4

2.5

 

T.C.

29.7

30.9

29.4

33.1

34.5

33.4

33.2

30.8

34.4

35.1

37.2

35.6

32.3

35.8

35.6

95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

27.9

28.2

22.8

22.5

16.6

30.6

30.9

25.2

24.8

17.7

33.3

33.7

27.6

27.1

18.7

 

KW

2.5

2.5

2.5

2.6

2.7

2.5

2.5

2.5

2.6

2.7

2.6

2.6

2.5

2.6

2.7

 

T.C.

28.0

28.6

26.6

30.1

31.4

30.9

30.7

27.9

31.4

32.0

33.9

32.8

29.2

32.6

32.5

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

25.9

26.3

21.6

21.5

15.6

28.2

28.6

23.8

23.7

16.7

30.4

30.9

26.0

25.9

17.8

 

KW

2.7

2.7

2.7

2.8

2.9

2.7

2.7

2.7

2.8

2.9

2.8

2.8

2.7

2.8

2.9

 

T.C.

26.3

26.4

23.9

27.3

28.4

28.6

28.3

25.1

28.5

28.9

30.8

30.1

26.3

29.6

29.5

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

24.0

24.5

20.4

20.4

14.6

25.8

26.3

22.4

22.5

15.8

27.6

28.2

24.4

24.6

17.0

 

KW

2.9

2.9

2.9

3.0

3.1

2.9

2.9

2.9

3.0

3.1

3.0

3.0

2.9

3.0

3.1

 

T.C.

24.7

24.2

21.2

24.5

25.3

26.2

25.8

22.3

25.5

25.9

27.6

27.4

23.4

26.6

26.5

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

22.1

22.7

19.3

19.4

13.5

23.4

24.1

21.1

21.4

14.9

24.8

25.5

22.8

23.4

16.2

 

KW

3.1

3.1

3.1

3.1

3.2

3.1

3.1

3.1

3.2

3.3

3.2

3.2

3.1

3.2

3.3

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

Air Handler

Coil

T.C.

S.C.

KW

FC/MC/PC37A

1.00

1.00

1.00

FC/MC/PC/UC48

1.00

1.00

1.00

HC42

1.00

1.00

1.00

AHP36

1.00

1.00

1.00

AV36

1.01

1.02

0.92

F5FP048

1.00

1.00

1.00

MA12B

FC/MC43B

1.00

1.00

1.00

MA14D

FC/MC48D

1.00

1.00

1.00

MV16C

FC/MC43C

1.01

1.02

0.92

MV16C

FC/MC48C

1.01

1.03

0.92

MV20D

FC/MC48D

1.01

1.03

0.92

MV12D

FC/MC48D

1.01

1.03

0.92

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

PV8*A12

FC/MC/PC37A

1.01

1.02

0.92

PV9*A12

FC/MC/PC37A

1.01

1.02

0.92

PV8*B16

FC/MC/PC43B

1.01

1.02

0.92

PV8*C16

FC/MC/PC43C

1.01

1.02

0.92

PV8*C20

FC/MC/PC43C

1.01

1.02

0.92

P(C,V)9*B12

FC/MC/PC43B

1.00

1.01

0.91

P(C,V)9*C16

FC/MC/PC43C

1.01

1.02

0.92

P(C,V)9*C20

FC/MC/PC43C

1.01

1.02

0.92

PV8*C16

FC/MC/PC48C

1.01

1.02

0.92

PV8*C20

FC/MC/PC48C

1.01

1.02

0.92

P(C,V)9*C16

FC/MC/PC48C

1.01

1.02

0.92

P(C,V)9*C20

FC/MC/PC48C

1.01

1.02

0.92

P(C,V)9*D20

FC/MC/PC48D

1.01

1.02

0.92

PV8*C16

HC42

1.01

1.02

0.92

PV8*C20

HC42

1.01

1.02

0.92

P(C,V)9*C16

HC42

1.01

1.02

0.88

P(C,V)9*C20

HC42

1.01

1.02

0.92

Johnson Controls Unitary Products

15

Image 15
Contents Warranty FeaturesDescription TCGD12 TCGD18 TCGD24 TCGD30 TCGD36 TCGD42 TCGD48 TCGD60 ModelFC/MC/PC/UC18B3X AHP18B2A AHP24B2A AHP30B2A AHP36C2AAHP42C2C AHP/SHP60D2C AV24B2A AV36C2A AV/SV48D2C FC/MC/PC/UC18A3XFootnotes ProceduresUnit Model AIR Handler Seer AC with MV Variable SpeedSeer AC with AV / SV / F*FV Variable Speed Seer EER CFM Condenser only DataUnit AIR Handler Cooling Rated NET MBH ModelFC/MC/PC35 FC/MC/PC18FC/MC/PC24 FC/MC/PC32Seer AC with Variable Speed FURNACES2 FC/MC/PC48D FC/MC/PC48CTypical Field Wiring AccessoriesSound Power Ratings Typical InstallationCooling Performance Data FC/MC/PC/UC24 AHP18 AHP24MA08B FC/MC18B FC/MC24B MV12B MA08B FC/MC35B FC/MC36B FC/MC43B MV12B FC/MC/PC32 FC/MC/PC35 FC/MC/PC37 FC/MC/PC43FC/MC/PC35A FC/MC/PC32 FC/MC/PC37 FC/MC/PC43AHP30 AHP36 MA12B FC/MC35B FC/MC43B MV12B MV16C FC/MC43C FC/MC35CFC/MC/PC37A FC/MC/PC/UC48 Indoor Coil Model no FC/MC/PC43 CondensingMA16C FC/MC43C MA14D FC/MC48D FC/MC48C MV16C MV20D Indoor Coil Model no FC/MC/PC48 Condensing AHP/SHP60 AV/SV48MA16C FC/MC48C MA20D FC/MC48D MV16C MV20D MA20D FC/MC62D MV20D

TCGD12 THRU 60 specifications

The York TCGD12 THRU 60 is a highly efficient and versatile unit designed for commercial and industrial applications. This series of air-cooled chiller and heat pump systems is renowned for its reliability and advanced technologies, making it a popular choice among HVAC professionals.

One of the main features of the TCGD12 THRU 60 is its impressive energy efficiency. The unit employs a sophisticated design that significantly reduces energy consumption while maintaining optimal performance. The incorporation of variable speed compressors allows the system to adjust its cooling capacity according to the actual load, resulting in lower operating costs and enhanced energy savings.

Another notable characteristic is its use of environmentally friendly refrigerants. This series adheres to the latest industry standards, utilizing refrigerants that minimize environmental impact. This commitment to sustainability ensures that users can operate their systems with a reduced carbon footprint, aligning with modern regulations and corporate responsibility goals.

The TCGD12 THRU 60 also features a robust control system that simplifies operation and enhances performance monitoring. Advanced controls enable users to set customized operating parameters and schedule maintenance, improving the unit's longevity and reliability. With an intuitive interface, operators can easily manage system settings to optimize comfort and efficiency.

In terms of construction, the TCGD12 THRU 60 is built with durable materials designed to withstand harsh operating conditions. The exterior casing is weather-resistant, ensuring that the unit can perform reliably in varying climates. Additionally, the system's design promotes ease of installation and maintenance, reducing downtime and service costs.

Noise reduction is yet another defining feature of this series. The TCGD12 THRU 60 incorporates advanced sound-dampening technologies, allowing for quieter operation, making it suitable for sound-sensitive environments like schools, hospitals, and office buildings.

Lastly, the unit's versatility is paramount. With options for air or water-cooled systems, the TCGD12 can be tailored to fit different applications and installation requirements. Whether for cooling, heating, or both, this unit provides a comprehensive solution for modern HVAC needs. Overall, the York TCGD12 THRU 60 stands out for its efficiency, advanced technology, and robust design, representing a significant step forward in the field of commercial heating and cooling solutions.