York YCJF24 warranty Cooling Capacity YCJF48S41S1 With Variable Speed Furnaces

Page 17

413437-YTG-C-0908

COOLING CAPACITY - YCJF48S41S1 With Variable Speed Furnaces

VARIABLE SPEED

COIL

 

 

 

COOLING

 

 

FURNACE MODEL

MODEL1

W

RATED

Net MBH

SEER

EER

 

CFM

TOTAL

SENS.

 

 

 

 

 

 

14.5 SEER AC WITH VARIABLE SPEED FURNACES2

 

 

 

PV8*C16

FC/MC/PC48C

21

1500

46.5

31.8

14.50

12.25

PV8*C20

FC/MC/PC48C

21

1600

47.0

32.8

14.75

12.50

P(C,V)9*C16

FC/MC/PC48C

21

1600

46.5

32.8

14.50

12.25

P(C,V)9*C20

FC/MC/PC48C

21

1600

47.0

32.8

14.75

12.50

PV8*C16

FC/MC/PC60C

21

1500

46.5

32.0

14.50

12.25

PV8*C20

FC/MC/PC60C

21

1600

47.0

32.8

14.75

12.50

P(C,V)9*C16

FC/MC/PC60C

21

1600

46.5

32.8

14.50

12.25

P(C,V)9*C20

FC/MC/PC60C

21

1600

47.0

32.8

14.75

12.50

P(C,V)9*D20

FC/MC/PC60D

24

1550

47.0

33.0

15.00

12.75

PV8*C16

HD48

21

1500

46.5

31.6

14.50

12.25

PV8*C20

HD48

21

1600

47.0

32.8

14.75

12.50

P(C,V)9*C16

HD48

21

1600

46.5

32.6

14.50

12.25

P(C,V)9*C20

HD48

21

1600

47.0

32.6

14.75

12.50

P(C,V)9*D20

HD48

24

1550

47.0

32.8

15.00

12.75

PV8*C16

HD60

21

1500

47.0

32.4

15.00

12.50

PV8*C20

HD60

21

1600

47.5

33.4

15.00

12.75

P(C,V)9*C16

HD60

21

1600

47.5

33.2

14.75

12.50

P(C,V)9*C20

HD60

21

1600

47.5

33.4

15.00

12.75

P(C,V)9*D20

HD60

24

1550

48.0

33.6

15.25

13.00

PV8*C20

FC/MC62D

21

1600

47.0

33.0

15.00

12.75

P(C,V)9*C16

FC/MC62D

21

1600

47.0

32.8

14.75

12.25

P(C,V)9*C20

FC/MC62D

21

1600

47.0

33.0

15.00

12.50

P(C,V)9*D20

FC/MC62D

24

1550

47.5

33.0

15.25

12.75

Y*(8,L)C*C16

FC/MC/PC48C

21

1615

47.0

33.0

14.75

12.50

Y*(8,L)C*C20

FC/MC/PC48C

21

1640

47.0

33.0

14.75

12.50

Y*9C*C16

FC/MC/PC48C

21

1590

46.5

32.8

14.75

12.50

Y*9C*C20

FC/MC/PC48C

21

1655

46.5

32.8

14.75

12.50

Y*9C*D20

FC/MC/PC48D

24

1645

46.5

33.0

14.75

12.50

Y*(8,L)C*C16

FC/PC60C

21

1625

47.0

33.0

15.00

12.75

Y*(8,L)C*C20

FC/PC60C

21

1605

47.0

33.2

15.25

13.00

Y*9C*C16

FC/PC60C

21

1590

47.0

33.0

14.75

12.50

Y*9C*C20

FC/PC60C

21

1655

47.0

33.0

14.75

12.50

Y*9C*D20

FC/MC/PC60D

24

1615

47.0

33.0

14.75

12.50

Y*(8,L)C*C20

FC/MC62D

21

1615

47.5

33.6

15.40

13.00

Y*9C*C20

FC/MC62D

21

1655

47.0

33.2

14.75

12.50

Y*9C*D20

FC/MC62D

24

1630

47.0

33.4

15.00

12.75

Y*9C*D20

HC60

24

1615

45.0

32.4

14.50

12.00

Y*(8,L)C*C16

HD48

21

1615

46.5

32.6

14.75

12.25

Y*(8,L)C*C20

HD48

21

1640

46.5

32.6

14.75

12.25

Y*9C*C16

HD48

21

1590

46.5

32.4

14.50

12.25

Y*9C*C20

HD48

21

1655

46.5

32.4

14.50

12.25

Y*9C*D20

HD48

24

1645

46.5

32.6

14.50

12.25

Y*(8,L)C*C16

HD60

21

1625

47.0

33.6

15.00

12.50

Y*(8,L)C*C20

HD60

21

1605

47.0

33.6

15.50

13.00

Y*9C*C16

HD60

21

1590

47.0

33.4

14.75

12.50

Y*9C*C20

HD60

21

1655

47.0

33.4

14.75

12.50

Y*9C*D20

HD60

24

1615

47.0

33.4

14.75

12.50

G*9V*C16

FC/MC/PC48C

21

1590

46.5

32.8

14.75

12.50

G*9V*C20

FC/MC/PC48C

21

1655

46.5

32.8

14.75

12.50

G*9V*D20

FC/MC/PC48D

24

1645

46.5

33.0

14.75

12.50

G*9V*C16

FC/PC60C

21

1590

47.0

33.0

14.75

12.50

For notes see Page 18.

Johnson Controls Unitary Products

17

Image 17
Contents Technical Guide Model Physical and Electrical DataJohnson Controls Unitary Products Footnotes ProceduresCooling Capacity With Air Handler Coils Seer AC with AHP / SHP / F*FP Seer ACSpeed Total Sens FurnaceCooling Unit Model CFM Range Rated NET MBH SEER1 Variable Speed Coil Cooling Furnace Model MODEL1 Rated Cooling Capacity YCJF24S41S1 With Variable Speed FurnacesSeer EER CFM Seer AC with Variable Speed FURNACES2Cooling Furnace Model MODEL1 Rated Variable SpeedCooling Capacity YCJF30S41S1 With Variable Speed Furnaces 1050 29.8 21.8 15.50 13.25 Cooling Capacity YCJF36S41S1 With Variable Speed Furnaces UC60C FC/PC60C Cooling Capacity YCJF42S41S1 With Variable Speed Furnaces UC48C Cooling Capacity YCJF48S41S1 With Variable Speed Furnaces HC60D Cooling Capacity YCJF60S41S1 With Variable Speed FurnacesSound Power Ratings AIR Conditioner Model no YCJF24S41S1 Indoor Coil Model no TemperatureCondensing Entering AIRVariable Speed Coil Furnace AIR Conditioner Model no YCJF30S41S1 Indoor Coil Model no 9V*B12 HC36 9V*C16 HC42 9V*C20 9V*A12 HD36 AIR Conditioner Model no YCJF36S41S1 Indoor Coil Model no PV8*C16 HD48 PV8*C20 PC,V9*C16 PC,V9*C20 PC,V9*D20 AIR Conditioner Model no YCJF42S41S1 Indoor Coil Model no PV8*C16 HD48 PV8*C20 PC,V9*C16 PC,V9*C20 PC,V9*D20 HD60 AIR Conditioner Model no YCJF48S41S1 Indoor Coil Model no 9C*D20 HC60 LC*C16 HD48 LC*C20 9C*C16 9C*C20 HD60 9V*C16 AIR Conditioner Model no YCJF60S41S1 Indoor Coil Model no