York YCJF24 warranty Furnace, Cooling Unit Model CFM Range Rated NET MBH SEER1, Total Sens

Page 7

413437-YTG-C-0908

COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils

 

FURNACE**

COIL

 

 

COOLING

 

 

UNIT MODEL

CFM RANGE

 

RATED

NET MBH

SEER1

 

W

MODEL

EER

 

(Min.-max.)

CFM

 

 

 

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600 - 1000

14,17

FC/MC/PC24

800

24.8

17.3

14.00

12.00

 

600 - 1000

14,17

FC/MC/PC30

800

24.8

17.3

14.00

12.00

 

600 - 1000

14

FC/MC/PC32

800

25

17.6

14.50

12.35

 

600 - 1000

17,21

FC/MC/PC35

800

25

17.6

14.50

12.35

 

600 - 1000

14,17,21

FC/MC/PC36

800

25

17.6

14.00

12.00

 

600 - 1000

14

FC/MC/PC37

800

25.4

17.9

14.50

12.35

 

600 - 1000

17,21

FC/MC/PC43

800

25.2

18

14.70

12.50

 

600 - 1000

21

FC/MC/PC48

800

25.6

18.3

14.80

12.65

YCJF24S41S1

600 - 1000

14

HC18

800

24.2

16.7

14.00

12.00

 

600 - 1000

14

HC30

800

24.8

17.4

14.00

12.00

 

600 - 1000

17

HC36

800

25

17.6

14.00

12.00

 

600 - 1000

21

HC42

800

25.4

18

14.50

12.35

 

600 - 1000

14,17

HD24

800

25.4

17.7

14.50

12.35

 

600 - 1000

14,17,21

HD36

800

24.8

17

14.00

12.00

 

600 - 1000

21

HD48

800

25.6

17.9

14.50

12.35

 

600 - 1000

14,17

UC24

800

25

17.5

14.00

12.00

 

600 - 1000

14,17

UC30

800

25

17.5

14.00

12.00

 

800 - 1200

14,17

FC/MC/PC30

1000

28.8

20.6

14.00

12.00

 

800 - 1200

14,17

FC/MC/PC32

1000

29

21

14.00

12.00

 

800 - 1200

17,21

FC/MC/PC35

1000

29

21

14.00

12.00

 

800 - 1200

14,17,21

FC/MC/PC36

1000

29

21

14.00

12.00

 

800 - 1200

14

FC/MC/PC37

1000

29.6

21.6

14.50

12.35

YCJF30S41S1

800 - 1200

17,21

FC/MC/PC43

1000

29.6

21.6

14.50

12.35

800 - 1200

21,24

FC/MC/PC48

1000

30

21.8

14.50

12.35

 

 

800 - 1200

17

HC36

1000

29

21

14.00

12.00

 

800 - 1200

21

HC42

1000

29.6

21.6

14.25

12.10

 

800 - 1200

14,17,21

HD36

1000

28.8

20.2

14.00

12.00

 

800 - 1200

21,24

HD48

1000

29.8

21.4

14.50

12.35

 

800 - 1200

14,17

UC30

1000

29

20.8

14.00

12.00

 

1000 - 1400

17,21

FC/MC/PC35

1200

33.6

24.6

14.00

11.90

 

1000 - 1400

14,17,21

FC/MC/PC36

1200

33.4

24.2

14.00

11.85

 

1000 - 1400

14

FC/MC/PC37

1200

34.4

25.2

14.50

12.20

 

1000 - 1400

17,21

FC/MC/PC43

1200

34.4

25.2

14.50

12.20

YCJF36S41S1

1000 - 1400

21,24

FC/MC/PC48

1200

34.6

25.4

14.50

12.25

 

1000 - 1400

17

HC36

1200

33.6

24.6

14.00

11.90

 

1000 - 1400

21

HC42

1200

34.4

25.2

14.50

12.20

 

1000 - 1400

14,17,21,24

HD48

1200

34.6

25

14.50

12.20

 

1000 - 1400

21,24

UC60

1200

33.2

23.8

14.00

11.75

 

1200 - 1600

17,21

FC/MC/PC43

1400.00

40.50

30.40

14.00

12.00

 

1200 - 1600

21,24

FC/MC/PC48

1400.00

41.00

30.80

14.50

12.30

 

1200 - 1600

21,24

FC/MC/PC60

1400.00

41.00

30.80

14.50

12.30

YCJF42S41S1

1200 - 1600

21

HC42

1400.00

40.50

30.40

14.00

12.00

 

1200 - 1600

14,17,21,24

HD48

1400.00

41.00

30.40

14.25

12.10

 

1200 - 1600

21,24

HD60

1400.00

41.50

31.20

14.50

12.30

 

1200 - 1600

21,24

FC/MC62

1400.00

41.00

31.00

14.50

12.30

 

1400 - 1800

21,24

FC/MC/PC48

1600.00

46.50

32.80

14.25

12.10

 

1400 - 1800

21,24

FC/MC/PC60

1600.00

46.50

32.60

14.50

12.35

YCJF48S41S1

1400 - 1800

14,17,21,24

HD48

1600.00

46.50

32.60

14.50

12.35

 

1400 - 1800

14,17,21,24

HD60

1600.00

47.50

33.20

14.50

12.35

 

1400 - 1800

21,24

FC/MC62

1600.00

47.00

32.80

14.50

12.35

 

1600 - 2000

21,24

FC/MC/PC60

1800.00

54.50

38.50

13.80

11.90

YCJF60S41S1

1600 - 2000

24

HC60

1800.00

54.50

38.50

13.50

11.65

 

1600 - 2000

21,24

FC/MC62

1800.00

57.00

39.00

14.00

12.10

1.Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up.

Johnson Controls Unitary Products

7

Image 7
Contents Technical Guide Model Physical and Electrical DataJohnson Controls Unitary Products Footnotes ProceduresCooling Capacity With Air Handler Coils Speed Seer ACSeer AC with AHP / SHP / F*FP Cooling Unit Model CFM Range Rated NET MBH SEER1 FurnaceTotal Sens Seer AC with Variable Speed FURNACES2 Cooling Capacity YCJF24S41S1 With Variable Speed FurnacesVariable Speed Coil Cooling Furnace Model MODEL1 Rated Seer EER CFMCooling Furnace Model MODEL1 Rated Variable SpeedCooling Capacity YCJF30S41S1 With Variable Speed Furnaces 1050 29.8 21.8 15.50 13.25 Cooling Capacity YCJF36S41S1 With Variable Speed Furnaces UC60C FC/PC60C Cooling Capacity YCJF42S41S1 With Variable Speed Furnaces UC48C Cooling Capacity YCJF48S41S1 With Variable Speed Furnaces HC60D Cooling Capacity YCJF60S41S1 With Variable Speed FurnacesSound Power Ratings Entering AIR TemperatureAIR Conditioner Model no YCJF24S41S1 Indoor Coil Model no CondensingVariable Speed Coil Furnace AIR Conditioner Model no YCJF30S41S1 Indoor Coil Model no 9V*B12 HC36 9V*C16 HC42 9V*C20 9V*A12 HD36 AIR Conditioner Model no YCJF36S41S1 Indoor Coil Model no PV8*C16 HD48 PV8*C20 PC,V9*C16 PC,V9*C20 PC,V9*D20 AIR Conditioner Model no YCJF42S41S1 Indoor Coil Model no PV8*C16 HD48 PV8*C20 PC,V9*C16 PC,V9*C20 PC,V9*D20 HD60 AIR Conditioner Model no YCJF48S41S1 Indoor Coil Model no 9C*D20 HC60 LC*C16 HD48 LC*C20 9C*C16 9C*C20 HD60 9V*C16 AIR Conditioner Model no YCJF60S41S1 Indoor Coil Model no