HP B110I manual Replacing, moving, or adding hard drives, Recognizing hard drive failure

Page 13

Replacing, moving, or adding hard drives

Recognizing hard drive failure

CAUTION: Sometimes, a drive that has previously been failed by the controller may seem to be operational after the system is power-cycled or (for a hot-pluggable drive) after the drive has been removed and reinserted. However, continued use of such marginal drives may eventually result in data loss. Replace the marginal drive as soon as possible.

The HP Smart Array B110i SATA RAID Controller supports drive LED illumination only on systems with backplane support for drive LEDs.

The following items indicate a hard drive failure:

The following messages appear in ORCA: o 1784: Drive Array Failure

This indicates a drive failure in a logical volume.

o1784: Drive Array Logical Drive Failure

This indicates that the entire logical volume has failed. This may mean that multiple drives have failed.

The following POST messages appear when the system is restarted, as long as the controller detects at least one functional drive:

o1784: Drive Array Failure

o 1786: Drive Array Recovery Needed

ACU represents failed drives with a distinctive icon.

HP Systems Insight Manager (SIM) can detect failed drives remotely across a network. For more information about HP SIM, see the documentation on the Management CD.

The HP System Management Homepage (SMHP) indicates that a drive has failed.

In Windows operating systems, the Event Notification Service posts an event to the Microsoft® Windows® system event log and the IML.

In Linux operating systems, systems events are logged to /var/log/messages.

ADU lists all failed drives (on systems supported by SmartStart v8.25 or earlier).

ACU lists all failed drives (on systems supported by ACU v8.28.13.0 or later).

For additional information about diagnosing hard drive problems, see the HP ProLiant Servers Troubleshooting Guide on the HP website (http://www.hp.com/go/bizsupport).

Effects of a hard drive failure

When a hard drive fails, all logical drives that are in the same array are affected. Each logical drive in an array might be using a different fault-tolerance method. Therefore, each logical drive can be affected differently.

Replacing, moving, or adding hard drives 13

Image 13
Contents HP Smart Array B110i Sata RAID Controller User Guide Intended audience Contents Index Enabling the controller and setting the boot order Enabling and configuring the controllerHP ProLiant 100 Series servers HP ProLiant 300 Series serversOption ROM Configuration for Arrays Configuring an arrayArray Configuration Utility Installing a license key with Orca Installing a license key with ACU Enabling and configuring the controller Installing device drivers Installing device drivers and Management AgentsInstalling Management Agents Windows operating systemsInstalling device drivers and Management Agents Recognizing hard drive failure Replacing, moving, or adding hard drivesEffects of a hard drive failure Recovering from compromised fault tolerance Compromised fault toleranceReplacing hard drives Automatic data recovery rebuildGuidelines Abnormal termination of a rebuild Moving hard drives and arrays Adding drives Installing the Smart Array driver-Microsoft Windows Installing an optional Smart Array controllerMigrating hard drives to an optional Smart Array controller Migrating hard drives to an optional Smart Array controller Completing the migration to the Smart Array controller-Linux Installing the Smart Array driver-LinuxDiagnostic tools Diagnosing array problemsPreventing electrostatic discharge Electrostatic dischargeGrounding methods to prevent electrostatic discharge Taiwan battery recycling notice Battery replacement noticeRegulatory compliance notices Acronyms and abbreviations Index Index