HP B110I manual Compromised fault tolerance, Recovering from compromised fault tolerance

Page 14

RAID 0 configurations cannot tolerate drive failure. If any physical drive in the array fails, all RAID 0 logical drives in the same array also fail.

RAID 1 configurations can tolerate one drive failure. If one physical drive in a RAID 1 configuration fails, the RAID volume is still intact as a degraded RAID 1.

RAID 1+0 configurations can tolerate up to two drive failures as long as no failed drives are mirrored to one another.

A RAID 1+0 configuration of four drives consists of two RAID 1 volumes of two drives each. One drive from each RAID 1 volume can fail for a total of two failed drives. If both drives in one RAID 1 volume fail, the entire RAID 1+0 volume fails.

Compromised fault tolerance

CAUTION: When fault tolerance is compromised, data loss can occur. However, it may be possible to recover the data. For more information, see "Recovering from compromised fault tolerance (on page 14)."

If more drives fail than the fault-tolerance method can manage, fault tolerance is compromised, and the logical drive fails. If this failure occurs, the operating system rejects all requests and indicates unrecoverable errors.

For example, fault tolerance might occur when a drive in an array fails while another drive in the array is being rebuilt.

Compromised fault tolerance can also be caused by problems unrelated to drives. In such cases, replacing the physical drives is not required.

Recovering from compromised fault tolerance

If fault tolerance is compromised, inserting replacement drives does not improve the condition of the logical volume. Instead, if the screen displays unrecoverable error messages, perform the following procedure to recover data:

1.Power down the entire system, and then power it back up. In some cases, a marginal drive will work again for long enough to enable you to make copies of important files.

If a 1779 POST message is displayed, press the F2 key to re-enable the logical volumes. Remember that data loss has probably occurred and any data on the logical volume is suspect.

2.Make copies of important data, if possible.

3.Replace any failed drives.

4.After you have replaced the failed drives, fault tolerance may again be compromised. If so, cycle the power again. If the 1779 POST message is displayed:

a.Press the F2 key to re-enable the logical drives.

b.Recreate the partitions.

c.Restore all data from backup.

To minimize the risk of data loss that is caused by compromised fault tolerance, make frequent backups of all logical volumes.

Replacing, moving, or adding hard drives 14

Image 14
Contents HP Smart Array B110i Sata RAID Controller User Guide Intended audience Contents Index HP ProLiant 100 Series servers Enabling and configuring the controllerEnabling the controller and setting the boot order HP ProLiant 300 Series serversConfiguring an array Option ROM Configuration for ArraysArray Configuration Utility Installing a license key with Orca Installing a license key with ACU Enabling and configuring the controller Installing Management Agents Installing device drivers and Management AgentsInstalling device drivers Windows operating systemsInstalling device drivers and Management Agents Effects of a hard drive failure Replacing, moving, or adding hard drivesRecognizing hard drive failure Compromised fault tolerance Recovering from compromised fault toleranceGuidelines Automatic data recovery rebuildReplacing hard drives Abnormal termination of a rebuild Moving hard drives and arrays Adding drives Migrating hard drives to an optional Smart Array controller Installing an optional Smart Array controllerInstalling the Smart Array driver-Microsoft Windows Migrating hard drives to an optional Smart Array controller Installing the Smart Array driver-Linux Completing the migration to the Smart Array controller-LinuxDiagnosing array problems Diagnostic toolsGrounding methods to prevent electrostatic discharge Electrostatic dischargePreventing electrostatic discharge Regulatory compliance notices Battery replacement noticeTaiwan battery recycling notice Acronyms and abbreviations Index Index