HP Guide to Enabling and Configuring the Smart Array B110i SATA RAID Controller

Page 5

Enabling and configuring the controller

Enabling the controller and setting the boot order

The HP Smart Array B110i SATA RAID Controller is not enabled by default and must be enabled in RBSU.

For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website (http://www.hp.com/support/smartstart/documentation).

HP ProLiant 100 Series servers

To enable the controller and set boot order:

1.Power up the server.

2.When prompted during the start-up sequence, access RBSU by pressing the F10 key.

3.Select Advanced or Advanced Settings.

4.Select SATA Configuration or Hard Drive Configuration.

5.Change SATA #1 to RAID.

6.Return to the previous screen by pressing the Escape key.

7.Select the Boot Menu by pressing the right arrow key.

8.Select Hard Disk Drives.

9.To assign the HP Smart Array B110i SATA RAID Controller as the boot controller, set Ctrl 1 to HP Smart Array B110i SATA RAID Controller.

10.Press the F10 key to save the setting and to exit RBSU.

HP ProLiant 300 Series servers

To enable the controller and set boot order:

1.Power up the server.

2.When prompted during the start-up sequence, access RBSU by pressing the F9 key.

3.Select Advanced Settings.

4.Select Embedded SATA RAID.

5.Select Enabled.

6.Return to the previous screen by pressing the Escape key.

7.Select Boot Controller Order.

8.To assign the HP Smart Array B110i SATA RAID Controller as the boot controller, set Ctrl 1 to HP Smart Array B110i SATA RAID Controller.

9.Press the F10 key to save the settings and to exit RBSU.

Enabling and configuring the controller 5

Image 5
Contents HP Smart Array B110i Sata RAID Controller User Guide Intended audience Contents Index Enabling the controller and setting the boot order Enabling and configuring the controllerHP ProLiant 100 Series servers HP ProLiant 300 Series serversOption ROM Configuration for Arrays Configuring an arrayArray Configuration Utility Installing a license key with Orca Installing a license key with ACU Enabling and configuring the controller Installing device drivers Installing device drivers and Management AgentsInstalling Management Agents Windows operating systemsInstalling device drivers and Management Agents Effects of a hard drive failure Replacing, moving, or adding hard drivesRecognizing hard drive failure Recovering from compromised fault tolerance Compromised fault toleranceGuidelines Automatic data recovery rebuildReplacing hard drives Abnormal termination of a rebuild Moving hard drives and arrays Adding drives Migrating hard drives to an optional Smart Array controller Installing an optional Smart Array controllerInstalling the Smart Array driver-Microsoft Windows Migrating hard drives to an optional Smart Array controller Completing the migration to the Smart Array controller-Linux Installing the Smart Array driver-LinuxDiagnostic tools Diagnosing array problemsGrounding methods to prevent electrostatic discharge Electrostatic dischargePreventing electrostatic discharge Regulatory compliance notices Battery replacement noticeTaiwan battery recycling notice Acronyms and abbreviations Index Index