Table B-1 ZR30w Specifications (continued)
Power Source | 100 – 240 VAC, 50/60 Hz |
|
|
|
|
Altitude: |
|
|
Operating | 0 to 5000 m | 0 to 16,400 feet |
Storage | 0 to 12192 m | 0 to 40,000 feet |
|
|
|
Measured Power Consumption: |
|
|
Full Power | <185 watts |
|
Typical Settings | <130 watts |
|
Sleep | <2 watts |
|
Bezel Switch Off | <1 watt |
|
|
|
|
Input Terminal | One DVI connector with cable included; |
|
| one DisplayPort connector with cable |
|
| included |
|
|
|
|
Energy Saver Feature
When the monitor is in its normal operating mode, the monitor uses less than 130 watts and the Power light is blue.
The monitor also supports a reduced power state. The reduced power state will be entered into if the monitor detects the absence of either the horizontal sync signal and/or the vertical sync signal. Upon detecting the absence of these signals, the monitor screen is blanked, the backlight is turned off, and the power light is turned amber. When the monitor is in the reduced power state, the monitor will utilize less than 2 watts of power. There is a brief warm up period before the monitor will return to its normal operating mode.
Refer to the computer manual for instructions on setting energy saver features (sometimes called power management features).
NOTE: The above power saver feature only works when connected to computers that have energy saver features.