QuickSpecs
HP ProLiant ML330 Generation 6
Power Specifications
460W PSU Part Number |
|
|
|
|
|
|
|
|
|
|
| ||||
Operational Input Voltage Range |
| 90 to 135 |
|
|
|
|
|
|
|
|
| ||||
(Vrms) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Frequency Range (Nominal) (Hz) |
| 47 to 66 Hz |
|
|
|
|
|
|
|
|
| ||||
Nominal Input Voltage (Vrms) |
|
|
| 100 |
| 115 | 208 | 220 | 230 | 240 | |||||
Max Rated Output Wattage Rating |
|
| 460 |
| 460 | 460 | 460 | 460 | 460 | ||||||
Nominal Input Current (A rms) |
|
|
| 10 |
| 10 | 5 | 5 | 5 | 5 | |||||
Max Rated Input Wattage Rating (Watts) |
| 760 |
| 760 | 700 | 700 | 700 | 700 | |||||||
Max. Rated VA |
|
|
| 850 |
| 850 | 830 | 830 | 830 | 830 | |||||
Efficiency (%) |
|
|
| 65 |
| 65 | 65 | 65 | 65 | 65 | |||||
Power Factor |
|
|
| 0.9 |
| 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | |||||
Leakage Current (mA) |
|
|
| 3.5 |
| 3.5 | 3.5 | 3.5 | 3.5 | 3.5 | |||||
Maximum Inrush Current (A peak) |
|
| 450 |
| 450 | 450 | 450 | 450 | 450 | ||||||
Maximum Inrush Current duration (mS) |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HP 750W Power Supply |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Part Number - AC 750W PSU |
|
|
|
|
|
|
|
|
|
|
|
| |||
Input Voltage Range (Vrms) | 100 to 240 |
|
|
|
|
|
|
|
|
|
|
|
| ||
Frequency Range (Nominal) | 50/60 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
(Hz) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Nominal Input Voltage (Vrms) |
| 100 |
| 120 |
| 200 |
| 208 |
| 220 |
| 230 |
| 240 | |
Maximum Rated Output Wattage |
| 750 |
| 750 |
| 750 |
| 750 |
| 750 |
| 750 |
| 750 | |
Nominal Input Current (A rms) |
| 8.9 |
| 7.4 |
| 4.3 |
| 4.1 |
| 3.9 |
| 3.7 |
| 3.6 | |
Max Rated Input Wattage Rating |
| 857 |
| 847 |
| 824 |
| 825 |
| 820 |
| 820 |
| 820 | |
(Watts) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Max. Rated VA |
| 894 |
| 884 |
| 859 |
| 859 |
| 854 |
| 854 |
| 854 | |
Efficiency (%) at Max. Rated |
| 87.5 |
| 88.5 |
| 91 |
| 91 |
| 91.5 |
| 91.5 |
| 91.5 | |
Output Wattage |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Power Factor |
| 0.97 |
| 0.97 |
| 0.97 |
| 0.97 |
| 0.97 |
| 0.97 |
| 0.97 | |
Leakage Current (mA) |
| 0.42 |
| 0.50 |
| 0.83 |
| 0.87 |
| 0.92 |
| 0.96 |
| 1.00 | |
Max. Inrush Current (A peak) |
| 30 |
|
| 30 |
| 30 |
| 30 |
| 30 |
| 30 |
| 30 |
Max. Inrush Current duration |
| 20 |
|
| 20 |
| 20 |
| 20 |
| 20 |
| 20 |
| 20 |
(mS) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Maximum British Thermal Unit |
| 2925 |
| 2892 | 2812 |
| 2812 |
| 2797 |
| 2797 |
| 2797 | ||
Rating |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTE: It is highly recommended that you use the HP Power Advisor in defining the
The HP Power Advisor is located at:
DA - 13361 Worldwide QuickSpecs — Version 17 — | Page 40 |