QuickSpecs
HP ProLiant ML330 Generation 6
Technical Specifications
System Unit  | Tower Dimensions  | 7.87 x 16.81 x 24.13 in (200 x 427 x 613 mm)  | |
  | (H x W x D)  | 
  | 
  | 
  | (W/O foot stand)  | 
  | 
  | 
  | Tower Weight | Maximum:  | 30 kg  | 
  | (approximate)  | (All hard drives, power  | 
  | 
  | 
  | supplies and processors  | 
  | 
  | 
  | installed)  | 
  | 
  | 
  | Minimum:  | 16 Kg  | 
  | 
  | (One hard drive, power  | 
  | 
  | 
  | supply and processor  | 
  | 
  | 
  | installed)  | 
  | 
  | Input Requirements | Rated Line Voltage  | 100 to 240 VAC  | 
  | (per power supply)  | Rated Input Current  | 7.1 Amps (at 120VAC) to 3.5 Amps (at 240  | 
  | 
  | 
  | VAC)  | 
  | 
  | Rated Input Frequency  | 50 to 60 Hz  | 
  | 
  | Rated Input Power  | 852 W  | 
  | BTU Rating | Maximum  | 460W - 1773 BTU / hr (at 120 VAC), 1715 (at  | 
  | 
  | 
  | 240 VAC)  | 
  | 
  | 
  | 750W - 2892 BTU / hr (at 120 VAC), 2797 (at  | 
  | 
  | 
  | 240 VAC)  | 
  | 
  | 
  | 1200W - 3530 BTU / hr (at 120 VAC), 4600  | 
  | 
  | 
  | (at 240 VAC)  | 
  | Power Specifications | To review typical system power ratings use the Power Calculator which  | |
  | 
  | is available via the online tool located at URL: www.hp.com/go/proliant-  | |
  | 
  | ||
  | 
  | - Click on the system of interest. Example: ML330 G6  | |
  | 
  | - Follow the instructions of the next screens.  | |
  | Power Supply Output | Rated   | 460 (750) W (at 100 VAC),  | 
  | (per power supply)  | Power  | 460 (750) W (at 200 VAC)  | 
  | 
  | Maximum Peak Power  | 460 (750) W (at 100 VAC),  | 
  | 
  | 
  | 460 (750) W (at 200 VAC)  | 
  | 
  | 
  | NOTE: See Power Supply Specifications  | 
  | 
  | 
  | tables for complete details on 460W PSU and  | 
  | 
  | 
  | optional 750W.  | 
  | System Inlet  | Operating  | 50° to 95° F (10° to 35° C) at sea level with an  | 
  | Temperature | 
  | altitude derating of 1.8°F per 1,000 ft (1.0° C  | 
  | 
  | 
  | per every 305 m) above seal level to a  | 
  | 
  | 
  | maximum of 10,000 ft (3050 m) no direct  | 
  | 
  | 
  | sustained sunlight . Maximum rate of change  | 
  | 
  | 
  | is 18°F/hr (10°C/hr). The upper limit may be  | 
  | 
  | 
  | limited by the type and number of options  | 
  | 
  | 
  | installed. System performance may be  | 
  | 
  | 
  | reduced if operating with a fan fault or above  | 
  | 
  | 
  | 86°F (30°C).  | 
  | 
  | ||
  | Relative Humidity | Operating  | 10% to 90% relative humidity (Rh), 82.4°F  | 
  | 
  | (28°C) maximum wet bulb temperature, non-  | |
  | 
  | 
  | condensing.  | 
  | 
  | 10% to 95% relative humidity (Rh), 101.7°F  | |
  | 
  | 
  | (38.7°C) maximum wet bulb temperature,  | 
  | 
  | 
  | |
DA - 13361 Worldwide QuickSpecs — Version 17 —   | Page 41  |