QuickSpecs
HP ProLiant ML370 Generation 6
Power Specifications
HP 1200W Power Supply |
|
|
|
|
|
|
|
Part Number - AC |
|
|
|
|
|
| |
Operational Input Voltage | 100 to 240 |
|
|
|
|
|
|
Range (Vrms) |
|
|
|
|
|
|
|
Frequency Range (Nominal) | 50/60 |
|
|
|
|
|
|
(Hz) |
|
|
|
|
|
|
|
Nominal Input Voltage (Vrms) | 100 | 120 | 200 | 208 | 220 | 230 | 240 |
Maximum Rated Output Wattage | 800 | 900 | 1200 | 1200 | 1200 | 1200 | 1200 |
Nominal Input Current (A rms) | 9.7 | 9.0 | 7.0 | 6.8 | 6.4 | 9.1 | 5.9 |
Max Rated Input Wattage Rating | 930 | 1034 | 1348 | 1348 | 1348 | 1348 | 1348 |
(Watts) |
|
|
|
|
|
|
|
Max. Rated VA | 970 | 1079 | 1406 | 1406 | 1406 | 1406 | 1406 |
Efficiency (%) at Max. Rated | 86 | 87 | 89 | 89 | 89 | 89 | 89 |
Output Wattage |
|
|
|
|
|
|
|
Power Factor | 0.97 | 0.97 | 0.97 | 0.97 | 0.97 | 0.97 | 0.97 |
Leakage Current (mA) | 0.42 | 0.50 | 0.83 | 0.87 | 0.92 | 0.96 | 1.00 |
Max. Inrush Current (A peak) | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
Max. Inrush Current duration | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
(mS) |
|
|
|
|
|
|
|
Maximum British Thermal Unit | 3174 | 3530 | 4600 | 4600 | 4600 | 4600 | 4600 |
Rating |
|
|
|
|
|
|
|
To review typical system power ratings use the Active Answers HP Power Advisor which is available via the online tool located at URL:
To drill down to calculators:
-Click on: "ProLiant Servers"
-Click on the Server of interest. Example: DL370 G6 or ML370 G6
-Click on: "Power Calculator" link. (You may need to scroll down to see it)
DA - 13242 Worldwide QuickSpecs — Version 21 — | Page 46 |