QuickSpecs
HP ProLiant ML370 Generation 6
Technical Specifications
|
| is 10°C/hr (18°F/hr). The upper limit may be |
|
| limited by the type and number of options |
|
| installed. |
|
| System performance may be reduced if |
|
| operating with a fan fault or above 30°C |
|
| (86°F). |
| ||
|
| change is 20°C/hr (36°F/hr). |
Relative Humidity | Operating | 10 to 90% relative humidity (Rh), 28°C |
| (82.4°F) maximum wet bulb temperature, non- | |
|
| condensing. |
| 10 to 95% relative humidity (Rh), 38.7°C | |
|
| (101.7°F) maximum wet bulb temperature, |
|
| |
Altitude | Operating | 3048 m (10,000 ft). This value may be limited |
|
| by the type and number of options installed. |
|
| Maximum allowable altitude change rate is |
|
| 457 m/min (1500 ft/min). |
| 9144 m (30,000 ft). Maximum allowable | |
|
| altitude change rate is 457 m/min (1500 |
|
| ft/min). |
Acoustic Noise | Listed are the declared | |
| declared average bystander position | |
| (LpAm) when the product is operating in a 23°C ambient environment. | |
| Noise emissions were measured in accordance with ISO 7779 (ECMA | |
| 74) and declared in accordance with ISO 9296 (ECMA 109). | |
| Idle |
|
| L WAd | 4.6 B for 1P |
|
| Redundant |
| L pAm | 28 dB for 1P |
|
| Redundant |
| Operating |
|
| L WAd | 4.7 B for 1P |
|
| Redundant |
| L pAm | 29 dB for 1P |
|
| Redundant |
| NOTE: The Listed sound levels apply to standard shipping | |
| configurations. Additional options may result in increased sound levels. | |
Emissions | FCC Rating | Class B |
Classification (EMC) | Normative Standards | CISPR 22; EN55022; EN55024; FCC CFR 47, |
|
| Pt 15; |
|
| K22;K24; EN |
|
|
NOTE: Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements.
DA - 13242 Worldwide QuickSpecs — Version 21 — | Page 48 |