HP ESL9000 manual Removing the Robotics Controller, Robotics controller and electronics bay cover

Page 13

Installing the Memory Module

Note: The AC power distribution assembly is located in the base of the cabinet, behind the left tape drive access panel.

Removing the Robotics Controller

To remove the robotics controller:

1.Open the center access door on the rear of the library.

2.Remove the six Phillips screws that secure the cover over the electronics bay, and remove the cover (see Figure 1).

1 Robotics controller

2 Electronics bay cover

Figure 1: Robotics controller and electronics bay cover

3.Locate the robotics controller at J5/J6 of the backplane.

4.If present, disconnect the RS-232 cables at connectors J2 and J3 at the left edge of the robotics controller.

5.Remove the small Phillips screw that secures the robotics controller in the electronics bay.

6.Remove the robotics controller from the electronics bay.

HP StorageWorks ESL9000 Series Tape Library Memory Module Upgrade Guide

13

Image 13
Contents Hp StorageWorks ESL9000 series tape library memory module Page Contents Tables About this Guide Conventions Text SymbolsDocument Conventions Equipment Symbols Getting Help Rack StabilityHP Storage Website HP Technical SupportHP Authorized Reseller About this Guide Installing the Memory Module Preparing the Library for the Upgrade Robotics controller and electronics bay cover Removing the Robotics ControllerRemoving the memory module Removing and Replacing the Memory ModuleTurning the Library On Completing the ProcedureInitializing Non-Volatile RAM Setting the Library for HP ModeChanging the Library Mode Changing the Library Settings Press Configure SDLT110 Setting the Number of Tape Drives Configure library screen Press Calibrate All Calibrating the LibraryInstalling the Memory Module