HP Ultrium Tape Drive manual Hp-Ux Aix

Page 12

described in this manual. For further information about optimizing performance and making full use of the drive’s functions, please contact the software manufacturer or HP

 

 

HP-UX

AIX

Sun, Solaris

Linux

 

 

 

 

 

 

HP Omniback1

yes

yes

yes

yes

Legato Networker

yes

yes

yes

yes

 

 

 

 

 

Veritas NetBackup

yes

yes

yes

yes2

1.Cell Manager is only available on HP-UX or Windows

2.Redhat Server only (not Caldera, Suse, and so on)

12 Introduction

Image 12
Contents Generation 3 drives Version Date Changes Contents Verifying the Installation Purpose of this manual Related documentsDocuments specific to HP Ultrium drives Documentation mapDrives-general Interface How error correction works General documents and standardizationTel 800 854 7179 or 714 261 Irvine, CAPage Backup Applications IntroductionUltrium Drives in a Library IntroductionHP-UX AIX HP-UX Systems HP Servers and Workstations-HP-UXIntroduction Determining the Scsi ID HP-UX SystemsCreating the Device Files For an HP Ultrium drive, execute the followingSelect the following When you have exited sam, run ioscan to see the tape drive WhereTo create a device file with the following characteristics Run insf as followsFor compressed mode default What Next?Hardware path can be found from previous ioscan output HP-UX Systems HP Alpha Unix HP Alpha UnixHP Alpha Unix Add the following entry to your /dev/ddr.dbase fileWhat Next? Configuring the Device Files Determining the Scsi IDThis will produce output that looks similar to Device Filenames under AIX Configuring on Linux Systems LinuxDetermining the Scsi ID Linux LinuxThis should find a number of lines. One should look like Using the Seek and Tell Features of mt Where /dev/stp is the device fileLinux Sun Systems, Solaris 8, 9 Sun Systems, Solaris 8, 9This will produce output similar to the following This produces a list similar toDetermine the device file by typing Ls -l /dev/rmt/*m grep st@XDo a reconfigure boot When the system is down, rebootHP-Data Values Values for the parameters for name are as follows Specifies the Scsi ID target of the deviceSpecifies the LUN for the device Verifying the Installation Verifying the Installation of the Drive UnixTo verify the installation Verifying the InstallationFile The name of the file to archive, prefixed with ‘./’ Read the file back from tapeCompare the original with the restored version Change to the temporary directoryExtract the file from the tape Verifying the Installation Glossary GlossaryResponse to a filemark command Fibre Channel switching technologyFeatures required by that standard Point-to-point connection between itself and the fabricGlossary Glossary Index IndexAIX Index