York DJ 180 warranty Blower Motor and Drive Data, Static RESISTANCES1, Power Exhaust Performance

Page 23

261660-YTG-C-0707

TABLE 16: BLOWER MOTOR AND DRIVE DATA

 

 

 

 

MOTOR1

ADJUSTABLE MOTOR PULLEY

FIXED BLOWER PULLEY

 

BELT

 

MODEL

 

BLOWER

 

(NOTCHED)

 

DRIVE

RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EFF.

DESIG-

OUTSIDE

PITCH

BORE

DESIG-

OUTSIDE

PITCH

BORE

DESIG-

PITCH

 

SIZE

 

(RPM)

HP

FRAME

 

 

 

(%)

NATION

DIA.

DIA.

(IN.)

NATION

DIA.

DIA.

(IN.)

NATION

LENGTH

QTY.

 

 

 

 

 

 

 

 

 

 

(IN.)

(IN.)

 

 

(IN.)

(IN.)

 

 

(IN.)

 

 

Standard

850/1065

 

 

 

 

 

4.3-5.32

 

BK90

8.75

8.4

1

BX81

82.8

1

15 TON

 

 

5

184 T

83

1VP56

5.35

1-1/8

 

 

 

 

 

 

 

High

965/1190

BK80

7.75

7.4

1

BX78

79.8

1

 

Static

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17.5 &

Standard

870/1025

 

 

 

 

 

5.5-6.52

 

BK120

11.75

11.4

1-3/16

BX83

84.8

1

High

 

7.5

213 T

89

1VP68

6.75

1-3/8

 

 

 

 

 

 

 

20 TON

950/1120

BK110

10.75

10.4

1-3/16

BX81

82.8

1

Static

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard

975/1165

 

 

 

 

 

6.2-7.42

 

1B5V110

11.3

11.1

1-7/16

5VX860

86.0

1

25 TON

 

 

15

254 T

91

1VP75X

7.5

1-5/8

 

 

 

 

 

 

 

High

1140/1365

1B5V94

9.7

9.5

1-7/16

5VX840

84.0

1

 

Static

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.All motors have a nominal speed of 1800 RPM, a 1.15 service factor and a solid base. They can operate to the limit of their service factor because they are located in the moving air, upstream of any heating device.

2.Do NOT close this pulley below 1 turn open.

TABLE 17: STATIC RESISTANCES1

 

 

 

 

 

 

 

RESISTANCE, IWG

 

 

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

CFM

 

 

 

 

 

 

 

15 TON

 

 

17.5 TON

 

 

20 TON

 

 

25 TON

 

 

 

 

 

 

 

 

 

 

 

 

 

4500

6000

7200

6000

 

7500

 

9000

6000

8000

9400

7500

10000

12500

WET INDOOR COIL

 

0.1

0.1

0.1

0.1

 

0.1

 

0.1

0.1

0.1

0.1

0.1

0.1

0.1

 

18 KW

0.3

0.4

0.4

0.4

 

0.4

 

0.5

0.4

0.4

0.5

0.4

0.5

0.6

ELECTRIC HEAT OPTIONS

36 KW

0.3

0.4

0.5

0.4

 

0.5

 

0.5

0.4

0.5

0.5

0.5

0.5

0.6

54 KW

0.4

0.5

0.5

0.5

 

0.5

 

0.6

0.5

0.5

0.6

0.5

0.6

0.7

 

 

 

 

72 KW

0.4

0.5

0.5

0.5

 

0.5

 

0.6

0.5

0.5

0.6

0.5

0.6

0.7

ECONOMIZER OPTION

 

0.1

0.1

0.1

0.1

 

0.1

 

0.2

0.1

0.1

0.2

0.1

0.2

0.3

HORIZONTAL DUCT CONNECTIONS2

0.1

0.2

0.3

0.2

 

0.3

 

0.5

0.2

0.3

0.5

0.3

0.5

0.6

1.Deduct these resistance values from the available external static pressures shown in the respective Blower Performance Table (See Note 2 for exception.)

2.Since the resistance to air flow will be less for horizontal duct connections than for bottom duct connections, add these pressures to the ESP values on the respective unit’s blower performance table.

TABLE 18: POWER EXHAUST PERFORMANCE

MOTOR

 

 

 

STATIC RESISTANCE OF RETURN DUCTWORK, IWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPEED1

 

0.2

0.3

 

 

0.4

 

0.5

 

0.6

CFM

 

kW

CFM

kW

CFM

 

kW

CFM

 

kW

CFM

 

kW

 

 

 

 

 

HIGH2

5250

 

0.83

4500

0.85

4200

 

0.88

3750

 

0.93

3000

 

0.99

MEDIUM

4900

 

0.77

3900

0.79

3500

 

0.82

2900

 

0.85

-

 

-

LOW

4400

 

0.72

3700

0.74

3000

 

0.78

-

 

-

-

 

-

1.Power exhaust motor is a 3/4 HP, PSC type with sleeve bearings, a 48 frame and inherent protection.

2.The factory setting.

Unitary Products Group

23

Image 23
Contents Description Technical GuideTable of Contents Ton Magnum Model Number Nomenclature Product NomenclatureFeatures Unit Cutaway FACTORY-INSTALLED OptionsUnitary Products Group FIELD-INSTALLED Accessories Unitary Products Group GAS Heat Ratiings Sound Power RATING1Capacity Ratings ARI MBH Cooling Capacities for DJ1806500 Cooling Capacities for DJ2108000 Cooling Capacities for DJ240Cooling Capacities for DJ300 AIR Temp Altitude Feet Altitude Correction FactorsALTITUDE/TEMPERATURE Conversion Factor Volt and Standard Drive Volt Standard Drive 6000 7000 8000 9000 9400 965 980 1025 1065 1125 1170 870 900 930 950 980 995 1015 6000 7000 8000 9000 9400 7500 8750 10000 11250 12500 Static RESISTANCES1 Power Exhaust PerformanceBlower Motor and Drive Data Size DJ Electrical Data Without Powered Convenience Outlet240 DJ Electrical Data with Powered Convenience Outlet None 120.4 150 E18 13.5 37.5 Physical Data DJ Voltage LIMITATIONS1Electric Heat Correction Factors Supply FAN VFD WEIGHTS, in LBSFront View Dimensions Utilities Entry Data Rear View Dimensions Minimum Clearances Unit Dimensions DJ180, 210, 240 & 300 RainhoodUnit Center of Gravity Four and SIX Point Loads Dimension Unit Roof Curb DimensionsOCC General Guide SpecificationsOutdoor Condenser FAN Assembly Electric Heating DJ***C/E Models Other Factory Installed Options

DJ 180 specifications

York DJ 180 is a cutting-edge DJ controller that has made a significant impact on the electronic music scene, particularly among novice and professional DJs alike. Designed to offer a seamless mixing experience, it combines innovative technology and user-friendly features, making it a go-to choice for anyone looking to elevate their DJ skills.

One of the standout features of the York DJ 180 is its intuitive layout, which includes two robust jog wheels that offer excellent precision and responsiveness. These jog wheels are not only sensitive to touch but also offer adjustable resistance, allowing DJs to customize their setup according to their mixing style. The controller's large play/pause and cue buttons are positioned strategically for quick access, ensuring smooth transitions between tracks.

The DJ 180 also boasts a comprehensive array of controls, including eight backlit performance pads per deck. These pads allow users to trigger samples, loops, and effects effortlessly, enabling enhanced creativity on the fly. Additionally, the controller features dedicated EQ knobs and a built-in sound card, which allows for easy connection to external devices and enhanced audio quality.

Incorporating advanced technology, the York DJ 180 supports both USB and MIDI connections, ensuring compatibility with a wide range of software and hardware setups. Whether mixing with popular DJ software or using it as a standalone controller for live performances, this flexibility makes it an essential tool for any DJ.

Another notable characteristic of the York DJ 180 is its portability. Weighing in at just under six pounds and featuring a slim profile, it is designed for DJs on the move, making it easy to transport to gigs and events without compromising on functionality.

Furthermore, the controller includes built-in effects, such as delay, reverb, and flanger, allowing DJs to add unique touches to their sets without needing external equipment. This streamlined approach makes the York DJ 180 not just a controller but a complete performance solution.

In conclusion, the York DJ 180 is a technologically advanced DJ controller that balances portability and performance with user-friendly features. Whether you are just starting your DJ journey or are an experienced professional, the versatility and quality of the York DJ 180 make it an excellent choice for all music enthusiasts.