York 036-21103-003 specifications Physical and Electrical Data 1 & 3 Phase

Page 2

036-21103-003 Rev. A (0403)

PHYSICAL AND ELECTRICAL DATA - 1 & 3 Phase

MODEL

 

 

 

H1RA018S78

H1RA024S78

H1RA030S78

H1RA036S78

H1RA036S50

H1RA048S50

H1RA060S50

 

 

 

 

 

 

 

 

 

 

 

 

Unit Supply Voltage

 

 

230 – 1 – 50

 

 

380/415 – 3 – 50

 

 

 

 

 

 

 

 

 

 

Normal Voltage Range 1

 

207 to 253

 

 

 

342 to 455

 

Minimum Circuit Ampacity

9.8

14.6

20.4

20.8

7.3

 

10.8

 

13.3

 

 

 

 

 

 

 

 

 

 

 

Max. Qvercurrent Device Amps 2

15

25

35

35

15

 

15

 

20

Compressor Type

 

Recip

Recip

Recip

Recip

Recip

 

Recip

 

Recip

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor Amps

 

Rated Load

7.4

11.3

15.2

15.5

5.2

 

7.2

 

9.2

 

 

 

 

 

 

 

 

 

 

 

 

Locked Rotor

53

65

90

82

39

 

53

 

79

 

 

 

 

 

 

 

 

 

 

 

 

Crankcase Heater

 

No

No

No

No

No

 

No

 

No

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor Amps

Rated Load

.5

.5

1.8

1.8

.8

 

1.8

 

1.8

 

 

 

 

 

 

 

 

 

 

 

 

Fan Diameter Inches

18

18

18

18

18

 

22

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated HP

1/12

1/12

1/4

1/4

1/4

 

1/3

 

1/3

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor

 

 

Nominal RPM

970

970

900

900

1,100

 

1,075

 

1,075

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal CFM

1,650

1,650

2,350

2,350

2,250

 

3,200

 

3,300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Face Area Sq. Ft.

8.00

8.00

9.15

9.15

9.15

 

15.72

 

23.58

 

 

 

 

 

 

 

 

 

 

 

 

Coil

 

Rows Deep

1

1

1

1

1

 

1

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fin / Inches

14

14

16

16

18

 

18

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

Liquid Line OD

 

3/8

3/8

3/8

3/8

3/8

 

3/8

 

3/8

 

 

 

 

 

 

 

 

 

 

 

Vapor Line OD

 

3/4

3/4

3/4

3/4

3/4

 

7/8

 

7/8

 

 

 

 

 

 

 

 

 

 

Unit Charge (Lbs. - Oz.) 3

3 - 13

3 - 14

3 - 15

4 - 11

4 - 11

 

7 - 10

 

9 - 12

Charge Per Foot, Oz.

0.66

0.66

0.68

0.68

0.68

 

0.70

 

0.70

 

 

 

 

 

 

 

 

 

 

Operating Weight Lbs.

118

123

135

137

137

 

206

 

228

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Rated in accordance with ARI Standard 110, utilization range “A”.

2.Dual element fuses or HACR circuit breaker.

3.The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, refer to publication 035-15893-60*

All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request.

UNIT

DIMENSIONS

REFRIGERANT

CONNECTION

MODEL

 

(INCHES)

 

LINE SIZE

H1RA

 

 

 

 

 

 

 

 

 

A1

 

B

 

C

Liquid

Vapor

 

 

 

 

018S78

17

 

35

 

23

 

 

024S78

17

 

35

 

23

 

 

030S78

19

 

35

 

23

 

3/4”

036S78

19

 

35

 

23

3/8”

 

036S50

19

 

35

 

23

 

 

048S50

27

 

37

 

27

 

7/8”

060S50

39

 

37

 

27

 

 

 

 

 

1. Including fan guard

2

Unitary Products Group

Image 2
Contents Features DescriptionPhysical and Electrical Data 1 & 3 Phase Cooling Capacity With Air Handler Coils Cooling Performance SUCT. T/P AIR Temp on Condenser ModelAccessories Sound RatingsTypical Field Wiring 1 PH Application 018S78 036S78 Typical Field Wiring 3 PH Application 036S50 060S50G2FD024S17 Cooling Performance DataH1RA018S78A H1RA024S78A G2FD030S17H1RA030S78A H1RA036S50A G2FD036S17H1RA036S78A H1RA048S50A G2FD048S21H1RA060S50A FD060S24AMatching Indoor Compnents AIR HandlersUnitary Products Group Unitary 5005 Norman Product York Group Drive 73069