ACCESSORIES
Refer to Price Manual for specific model numbers.
Compressor Blanket - Designed to further reduce the nor- mal operating sound.
Hard Start Kit (Single Phase Units) - provides required starting torque for use with thermal expansion valve.
Outdoor Thermostat - 2TD06700124 - Consists of an adjustable outdoor thermostat and relay in a vented enclo- sure. It provides additional second stage control of the sup- plemental resistance heat.(Balance Point Control)
| ||
SOUND RATINGS |
|
|
|
|
|
UNIT MODEL | SOUND | |
RATINGS | ||
| DECIBELS | |
|
|
|
018 | 76 |
|
|
|
|
024 | 78 |
|
|
|
|
030 | 82 |
|
|
|
|
036 | 82 |
|
|
|
|
048 | 82 |
|
|
|
|
060 | 80 |
|
|
|
|
TYPICAL INSTALLATION - H*RA018S78 THRU 036S78 (1 PH) & H*RA 036S50 THRU 060S50 (3 PH)
| MINIMUM 18” SERVICE ACCESS |
| |
60” OVERHEAD | CLEARANCE ON ONE SIDE | THERMOSTAT TO FURNACE OR | |
| AIR HANDLER | ||
CLEARANCE | WEATHERPROOF | ||
TERMINAL BLOCK | |||
| |||
| DISCONNECT | ||
|
| ||
| SWITCH | NEC CLASS 1 WIRING | |
|
| NEC CLASS 2 WIRING |
10” CLEARANCE COIL AREA
TO INDOOR COIL
NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF.
SEAL OPENING(S) WITH
PERMAGUM OR EQUIVALENT
CONTROL ACCESS PANEL
Unitary Products Group | 5 |