INSTALLATION
INSTALLATION SAFETY INFORMATION
Read these instructions before continuing this appliance installation. This is an outdoor combination heating and cool- ing unit. The installer must assure that these instructions are made available to the consumer and with instructions to retain them for future reference.
1.Install this furnace only in a location and position as specified on Page 11 of these instructions.
2.This equipment is not to be used for temporary heating of buildings or structures under construction.
PRECEDING INSTALLATION
1.Remove the two screws holding the brackets in the front, rear and compressor side
Bracket | Turn down | |
Screws | ||
|
FIGURE 1 - UNIT SHIPPING BRACKET
2.Turn each bracket toward the ground and the protective plywood covering will drop to the ground.
3.Remove the condenser coil external protective covering prior to operation.
4.Remove the toolless doorknobs and instruction packet prior to installation.
Condenser
Coil External
Protective
Covering
Barometric Relief Hood in Shipping Loca- tion (if included)
FIGURE 2 - CONDENSER COVERING
Toolless
Doorknobs
Installation
Instruction
Packet
FIGURE 3 - COMPRESSOR SECTION
LIMITATIONS
These units must be installed in accordance with the follow- ing:
In U.S.A.:
1.National Electrical Code, ANSI/NFPA No. 70 - Latest Edition
2.Local building codes, and
3.Local plumbing and waste water codes, and
4.Other applicable local codes.
Refer to Tables 1 & 2 for unit application data.
If components are to be added to a unit to meet local codes, they are to be installed at the dealer’s and/or customer’s expense.
Size of unit for proposed installation should be based on heat loss/heat gain calculation made according to the methods of Air Conditioning Contractors of America (ACCA).
10 | Unitary Products Group |