York 120, 150 installation manual NOMENCLATURE, Additonal Options

Page 7

035-17311-002-A-0803

NOMENCLATURE, ADDITONAL OPTIONS:

AA

None

 

 

AB

Phase Monitor

 

 

AC

Coil Guard

 

 

AD

Dirty Filter Switch

 

 

AE

Phase Monitor & Coil Guard

 

 

AF

Phase Monitor & Dirty Filter Switch

 

 

AG

Coil Guard & Dirty Filter Switch

 

 

AH

Phase Monitor, Coil Guard, & Dirty Filter Switch

 

 

CA

CPC Controller with Dirty Filter Switch & Air Proving Switch

 

 

CB

CPC Controller, DFS, APS & Phase Monitor

 

 

CC

CPC Controller, DFS, APS & Coil Guard

 

 

CD

CPC Controller, DFS, APS, Phase Monitor, & Coil Guard

 

 

CE

CPC Controller, DFS, APS & Technicoat Cond. Coil

 

 

CF

CPC Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor

 

 

CG

CPC Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard

 

 

CH

CPC Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard

 

 

CJ

CPC Controller, DFS, APS & Technicoat Evap. Coil

 

 

CK

CPC Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor

 

 

CL

CPC Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard

 

 

CM

CPC Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard

 

 

CN

CPC Controller, DFS, APS & Technicoat Evap. & Cond Coils

 

 

CP

CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor

 

 

CQ

CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard

 

 

CR

CPC Controller, DFS, APS, Technicoat Cond Coils, Phase Monitor, & 2” Pleated Filters

 

 

CV

CPC Controller, DFS, APS, & 2” Pleated Filters

 

 

CX

CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, Coil Guard

 

 

HA

Honeywell Excel 10 Controller with Dirty Filter Switch & Air Proving Switch

 

 

HB

Honeywell Excel 10 Controller, DFS, APS & Phase Monitor

 

 

HC

Honeywell Excel 10 Controller, DFS, APS & Coil Guard

 

 

HD

Honeywell Excel 10 Controller, DFS, APS, Phase Monitor, & Coil Guard

 

 

HE

Honeywell Excel 10 Controller, DFS, APS & Technicoat Cond. Coil

 

 

HF

Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor

 

 

HG

Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard

 

 

HH

Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard

 

 

HJ

Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. Coil

 

 

HK

Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor

 

 

HL

Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard

 

 

HM

Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard

 

 

Unitary Products Group

7

Image 7
Contents Installation Manual Table of Contents List of Figures List of Tables Reference Safety ConsiderationsGeneral InspectionNomenclature ½ 12½ Ton Predator Model Number NomenclatureNOMENCLATURE, Additonal Options Johnson UNT Controller, DFS, APS & Phase Monitor Technicoat Condenser Coil, Phase Monitor, & Coil Guard Installation Safety Information InstallationPreceding Installation Location Unit Temperature LimitationsRigging and Handling Length of Forks Must be a Minimum of 60 Inches Point Load WeightDetail C Unit Dimensions Unit ClearancesBottom Duct Openings from Above Duct Covers DuctworkSide Panels with Hole Plugs Condensate Drain Power Wiring Detail Thermostat WiringControl Wire Sizes Power and Control WiringElectronic Thermostat Field Wiring RLA LRA FLA 380 11.5 75.0 Electrical Data DM120 10 TON with Power Convenience OutletPhysical Data OPTIONS/ACCESSORIESMinimum Supply AIR CFM Economizer Power ExhaustMinimum Position Adjustment Enthalpy SET Point AdjustmentEnthalpy SET Point Chart Belt Tension PhasingBlower Rotation Supply AIR Limitations1/2 TON Optional Motor Down Shot Blower PERFORMANCE* † 1/2 TON Standard Motor Down Shot Blower PERFORMANCE* †10 TON Optional Motor Down Shot Blower PERFORMANCE* † 10 TON Standard Motor Down Shot Blower PERFORMANCE* †12-1/2 TON Optional Motor Down Shot Blower PERFORMANCE* † 12-1/2 TON Standard Motor Down Shot Blower PERFORMANCE* †1/2 TON Optional Motor Side Shot Blower PERFORMANCE* † 1/2 TON Standard Motor Side Shot Blower PERFORMANCE* †4965 12-1/2 TON Optional Motor Side Shot Blower PERFORMANCE* † 12-1/2 TON Standard Motor Side Shot Blower PERFORMANCE* †Method ONE Method TWO Indoor Blower SpecificationsAIR Balance Checking AIR QuantityDRY Coil Delta P Supply AIR Drive Adjustment Sequence of Operations Overview OperationAdditional Static Resistance Motor Sheave Datum DiametersCooling Sequence of Operation Compressor Protection Safety ControlsElectric Heat Antictpator Setpoints Electric Heating Operation ErrorsElectric Heat Limit Setting Electric Heating Sequence of OperationsCharging the Unit START-UP Cooling12.5 TON Standard Efficiency Superheat Charging 10 TON Standard Efficiency Superheat ChargingGeneral Normal Maintenance TroubleshootingPredator Flash Codes Unit Control Board Flash Codes Basic Troubleshooting FlowchartCooling Troubleshooting Guide Unitary Products Group 035-17311-002-A-0803 Unitary 5005 Norman Products York Group Drive 73069