HP c8000 manual Shared memory extension Mitshm, Power saving states defined by Vesa

Page 24

configuring X Windows on HP-UX (HP Visualize graphics cards)

X Server configuration

The following table is a description of the states that are defined by VESA. The Power Savings column indicates (roughly) the level of power savings achieved in the given state. The Recovery Time is the amount of time that the screen takes to return to a usable state when the screen saver is turned off (by pressing a key or the moving the mouse).

Table 2-1

Power saving states defined by VESA

 

 

 

 

 

 

 

 

 

Level

 

State

DPMS Compliance

Power

Recovery Time

 

 

Requirements

Savings

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

Screen Saver

Not Applicable

None

Very Short (<1sec.)

 

 

 

 

 

 

 

 

1

 

Stand-by

Optional

Minimal

Short

 

 

 

 

 

 

 

 

2

 

Suspend

Mandatory

Substantial

Longer

 

 

 

 

 

 

 

 

3

 

Off

Mandatory

Maximum

System Dependent

 

 

 

 

 

 

 

The actual amount of power saved and the recovery time for each of the states is monitor-dependent and may vary widely. The customer can compensate for this by choosing an appropriate level for the monitor that is currently in use.

By default, the DPMS level used is the Screen Saver (i.e. no power savings). If you wish to use power saving during screen blanking, set the following X*screens file entry before starting the server:

MinimumMonitorPowerSaveLevel <level>

where level is replaced with the single digit 0, 1, 2, or 3 as specified in the Level column in the above table.

shared memory extension (MIT_SHM)

The MIT shared memory extension provides both shared-memory XImages and shared-memory pixmaps based on the SYSV shared memory primitives.

Shared memory XImages are essentially a version of the XImage interface where the actual image data is stored in a shared memory segment, and thus need not be moved through the Xlib interprocess communication channel. For large images, use of this facility can result in increased performance.

Shared memory pixmaps are a similar concept implemented for the pixmap interface. Shared memory pixmaps are two-dimensional arrays of pixels in a format specified by the X Server, where the pixmap data is

22

Chapter 2

Image 24
Contents Graphics administration guide Manufacturing Part Number B2355-IE003 Edition E0206Legal notice Contents Contents Windows configuration details Examples printing a key map Preface Preface Product Dis Obsoleted On Name NumberDocument conventions Document conventions Chapter Configuring X Windows on HP-UX Configuring X Windows on HP-UX HP Visualize graphics cards Graphics cards, see in this documentServer configuration Description of the X*screens configuration file Screens fileSyntax guidelines X*screens file formatScreen /dev/crt Server optionsDefaultVisual Screen entriesTransparent MinimumMonitorPowerSaveLevel value ScreenOptionsSample X*screens files Two physical displays, two separate screens Screen /dev/crt DefaultVisual Transparent Two physical displays, single logical screen Four physical displays, single logical screen Dev/crt0 Dev/crt1 Dev/crt2 Dev/crt3 Host0.0 Miscellaneous topics Double buffer extensionsPerforming buffer swaps on vertical blank Display power management signaling Dpms Determining swap performanceSupported devices Power saving states defined by Vesa Shared memory extension MitshmSupported X configurations Multi-display supportMulti-Display Multi-Screen Device #2Single logical screen Multi-screen support Single logical screen SLS3D acceleration and single logical screen Hp CDE and single logical screenServer configuration Hp Visualize- FXE, FX5 and FX10 device-dependent information Supported visualsHp VISUALIZE-FXE/5/10 configuration hints Supported screen optionsDisabling the GLX visuals Overlay visuals and overlay transparencyHp VISUALIZE-FXE/5/10 colormaps Changing the monitor typeOther graphics cards Configuring X Windows on HP-UX other graphics cards Using SAM to configure X Windows Using SAM to configure X Windows Using setmon to configure the monitor XF86Config file XF86Config file formatServerLayout section Absolute RightOf LeftOf Above Below Relative XF86Config file Option Value Default Description Files section Usr/lib/X11/Xserver/modules/xf86 Opt/graphics/common/lib Module section InputDevice section Option Value DescriptionScreen section XF86Config file Display subsection Entry Description PositionXF86Config file Monitor section Device section XF86Config file Sample XF86Config file Sample XF86Config file Sample XF86Config file Extensions Double buffer extension DBEDetermining swap performance Display power management signaling Dpms Dpms Dynamic library loading Features Cursor scalingGlx visual suppression Visuals suppression Technical print service TPS Virtual frame buffer XvfbSecurity DefaultVisual option Starting the X Server from the command lineClass Minimum monitor power save level option DisableGlxVisualsDepth NoServerLoggingHideDuplicateGlxVisuals Input devices KeyboardsPointers Output devices Hp Fire GL-UX device-dependent informationSupported visuals Supported device optionsSupported monitor configurations Option Overlay True Option TransparentIndex0ATI FireGL X1/T2/X3 device-dependent information TrueColor optional Overlay Image FSAAScale Supported monitor configurations Hp Fire GL-UX configuration hints Overlay visuals and overlay transparencyNumLongs/sizeofOverlayVisualPropertyRec HP Fire GL-UX Colormaps Hints System requirements Hardware compatibility tableATI FireGL X1/X3/T2-128Miscellaneous FontsFiles File DescriptionATI FireGL X1/T2/X3 configuration hints Gamma correction Windows configuration details Using an /etc/hosts file Making an x*.hosts fileCustomizing the mouse and keyboard Stopping the X Window systemChanging mouse button actions Modifying modifier key bindings with xmodmap Specifying key remapping expressions To do this Use this expressionExamples Printing a key mapMaking an x*.hosts file Making an x*.hosts file Chapter
Related manuals