Roberts Gorden CRV-Series CRV-SERIES Assembly Overview, Major Component Descriptions Burner Tube

Page 10

ROBERTS GORDON® CRV-SE RI ES SUBMI TT AL SHE ET

CRV-SERIES ASSEMBLY OVERVIEW

Major Component Descriptions

Burner

Tube

 

Hot Rolled, Heat Treated or

 

Coated Aluminized Tube

 

supplied in 10' (3 m) lengths.

Reflector

Reflector with Hole

 

(Aluminum or

 

(Aluminum or

 

Stainless Steel)

 

Stainless Steel)

 

Alternate overlap as

 

Alternate overlap as

 

shown on overview.

 

shown on overview.

 

Minimum overlap is 7"

 

Minimum overlap is 7"

 

(18 cm).

 

(18 cm).

 

 

 

Flex Gas Line

45° Elbow

90° Elbow

with shut-off cock

 

 

Cross

Combustion Chamber

Tee

Coupling Assembly

Tube Adapter

End Vent

 

 

with Lock

 

 

© 2004 Roberts-GordonBEFORE IN STALLATI ON AND OPER ATI ON OF HEATI NG EQUIPMENT, READ AND U NDERSTAND THE INSTALLATION, OPERATIO N AND SERVICE MANUAL .

APPLICATION S, ENGI NEERING AND DETAI LED GUID ANCE ON SYSTEMS DESIGN, INSTALLATI ON AND PRODUCT PERFORMANCE IS AVAI LABLE UPON REQUEST. ROBERTS GORDON® PRODUCTS ARE TO BE INSTALLED ONLY IN ACCORDANCE WI TH LOCAL LAWS, CODES AND REGULATIONS, AND ONLY BY A CONTRACTOR QUALI FIED I N THE I NSTALLATION AND SERVICE OF GAS-FIRED HEATING EQUI PMENT.

Image 10
Contents Custom-Engineered, Low-Intensity Infrared Heating Systems Copyright 2004 Roberts-Gordon N127602NA Rev B 07/04Contents of CRV-Series Burner Carton Standard Parts ListCommon CRV-Series Components Urvccm Pump Packages and Accessories 02719105 EP-100 Pump Package General Specifications Pump Specifications Model EP-100 EP-201 EP-203 EP-301 Pump SpecificationsAir Supply Blower Specifications One Side Reflector Inches Centimeters Clearances to CombustiblesStandard Reflector Inches Centimeters Two Side Reflectors Inches CentimetersUniversal Shield, Position Inches Centimeters Model Inches CentimetersFoot Deco Grille Inches Centimeters Barrier Shield Inches CentimetersMajor Component Descriptions Burner Tube CRV-SERIES Assembly OverviewCoupling Assembly Tube Adapter With LockAssembly Tube and Reflector Hanger With Clamp PackageRoberts Gordon UltravacCRV-Series Assembly Overview Heater Installation Critical Hanger PlacementCombustion Chamber 229 cm Tube InstallationCoupling and Tube Assembly Tube Hanger Turnbuckles 10 maximum 3 m ChamberElbow Installation Coupling and Tube Assembly Tighten Slide Bar as shown belowElbow Package Configuration Repeat a D until all tubes are assembledReflector Installation Reflector InstallationReflector Installation with Hole Per sideReflector, U-Clip and Reflector Support Installation Burner Installation Burner Combustion Chamber Gasket End VentReflector Joint Installation Optional Heater AccessoriesTee Installation TeeReflector Joint Detail JointSide Reflector Installation Bracket InstallationReflector Side Extension Standard Reflector Frame Shield Installation TWO-FOOT Decorative Grille InstallationGrille Installation ShieldOne-Foot Decorative Grille Bracket ONE-FOOT Decorative Grille InstallationDecorative Grille Bracket Reinforcement Decorative GrilleJoint Piece and Reinforcement Joint PieceEnd Piece and Reflector End Cap Reflector joint pieceProtective Grille Installation Silicone Cap InstallationCRV-Series Classic Cast-Iron Components Pump Installation EP-200 Condensate Valve AssemblyVenting Vertical Venting ConfigurationEP-100 Horizontal Venting Configurations Horizontal Venting 4 10 CM PipeEP-300 Series Horizontal Venting Configurations EP-200 Series Horizontal Venting Configurations18 46 cm Minimum Outside Combustion AIR Supply Filter Housing AssemblyAir Supply Blower Support Non-Pressurized Outside Air Supply Pressure SwitchPressurized Outside Air Supply Vent CapGAS Piping Gas Connection with Stainless Steel Flex Gas Connector30 cm Stainless Steel Flex Wiring One Zone Operation without Control PanelBlack Two Zone Operation without Control PanelDpst 12A Transformer Relay Zone Thermostat Purple Red White Red/YellowCRV-Series Burner Internal Wiring GAS Valve Ignition ModuleInternal Burner Diagram Gasket Burner to Mixing Chamber TransformerROBERTS-GORDON will not PAY for Warranty is Void ifLimitations on Authority Representatives

CRV-Series specifications

The Roberts Gordon CRV-Series is a revolutionary line of infrared heating systems designed to provide efficient and effective solutions for a variety of industrial and commercial applications. With an emphasis on energy efficiency, performance, and reliability, the CRV-Series stands out as a preferred choice among business owners looking to optimize their heating solutions.

One of the main features of the CRV-Series is its innovative heating technology. The systems utilize infrared radiation to directly warm objects and individuals in a space, rather than heating the air. This results in faster heating times and a more comfortable environment, as it reduces heat loss and minimizes the need to overly heat the air itself. Consequently, users enjoy lower energy bills and improved comfort levels.

The CRV-Series is available in various configurations, allowing for versatility in installation and use. The modular design means that units can be easily adapted to suit different space requirements, whether in warehouses, manufacturing plants, or retail environments. This adaptability is complemented by a range of heating capacities, ensuring that businesses can find a model that fits their unique needs.

Another key characteristic of the CRV-Series is its robust construction. Built with high-quality materials, the systems are designed to withstand the rigors of industrial settings. This durability contributes to their long operational lifespan, reducing the need for frequent replacements and minimizing downtime.

Safety is also a paramount concern addressed by the CRV-Series. The systems are equipped with advanced safety features such as flame detection, automatic shut-off valves, and over-temperature protection. These features not only ensure safe operations but also provide peace of mind to users.

In terms of control and efficiency, the CRV-Series is compatible with advanced control systems that enable precise temperature regulation. This capability allows businesses to tailor their heating operations to match production schedules or occupancy levels, further enhancing energy savings.

Overall, the Roberts Gordon CRV-Series represents a blend of innovative technology, energy efficiency, and durability tailored for today's industrial and commercial environments. With its direct heating capabilities and robust features, it stands as a leading choice for businesses looking to improve their heating strategies while minimizing costs and environmental impact. Through its commitment to quality and performance, Roberts Gordon continues to set the standard in infrared heating technology with the CRV-Series.