Roberts Gorden CRV-Series service manual Reflector Installation with Hole, Per side

Page 17

ROBERTS GORDON ® CRV-SE RI ES SUBM ITT AL SHE ET

REFLECTOR INSTALLATION

Reflector Installation with Hole

 

Reflector

 

 

with Hole

 

Slide Reflector

 

 

with hole

 

through hanger.

 

Unhook combustion

 

chamber from chain

 

and insert through hole.

 

Reconnect chain.

 

 

 

Hanger

 

 

Tube

Description

Part Number

Combustion

Tube/Reflector Hanger

03090100

Chamber

Tube

91409XXX

 

Reflector with Hole

02750304

 

Reflector Installation

Wire Form

 

Reflector

Sheet Metal

 

Screw

 

 

 

Reflector Support

Tube

 

Strap

 

 

 

 

U-Clip

 

 

(2 clips per

 

 

alternate overlaps

Description

Part Number

per side)

Reflector Support Package

03050010

 

U-Clip Package

91107720

 

Reflector End Cap

027508XX

 

© 2004 Roberts-GordonBEFORE INSTALLATIO N AND OPERATI ON OF HEATIN G EQUI PMENT, READ AND UNDERSTAND THE I NSTALLATION, O PERATION AND SERVICE MANUAL .

APPLI CATIONS, ENGIN EERING AND DETAI LED GUIDANCE ON SYSTEMS DESI GN, I NSTALLATION AND PRODUCT PERFORMANCE I S AVAILABLE UPO N REQUEST. ROBERTS GO RDON® PRODUCTS ARE TO BE INSTALLED ONLY I N ACCOR DANCE WITH LOCAL LAW S, CODES AND REGULATIONS, AND ONLY BY A CONTRACTO R QUALI FIED IN THE INSTALLATION AND SERVICE OF GAS-F IRED HEATING EQUIPMEN T.

Image 17
Contents Copyright 2004 Roberts-Gordon N127602NA Rev B 07/04 Custom-Engineered, Low-Intensity Infrared Heating SystemsCommon CRV-Series Components Standard Parts ListContents of CRV-Series Burner Carton Urvccm Pump Packages and Accessories 02719105 EP-100 Pump Package General Specifications Air Supply Blower Specifications Pump SpecificationsPump Specifications Model EP-100 EP-201 EP-203 EP-301 Standard Reflector Inches Centimeters Clearances to CombustiblesOne Side Reflector Inches Centimeters Two Side Reflectors Inches CentimetersInches Centimeters Universal Shield, Position Inches Centimeters ModelBarrier Shield Inches Centimeters Foot Deco Grille Inches CentimetersCoupling Assembly Tube Adapter CRV-SERIES Assembly OverviewMajor Component Descriptions Burner Tube With LockTube and Reflector Hanger With Clamp Package AssemblyUltravac Roberts GordonCRV-Series Assembly Overview Critical Hanger Placement Heater InstallationCoupling and Tube Assembly Tube InstallationCombustion Chamber 229 cm Tube Hanger Turnbuckles 10 maximum 3 m ChamberElbow Package Configuration Coupling and Tube Assembly Tighten Slide Bar as shown belowElbow Installation Repeat a D until all tubes are assembledReflector Installation with Hole Reflector InstallationReflector Installation Per sideReflector, U-Clip and Reflector Support Installation Burner Combustion Chamber Gasket End Vent Burner InstallationTee Installation Optional Heater AccessoriesReflector Joint Installation TeeJoint Reflector Joint DetailReflector Side Extension Bracket InstallationSide Reflector Installation Standard Reflector Grille Installation TWO-FOOT Decorative Grille InstallationFrame Shield Installation ShieldDecorative Grille Bracket ONE-FOOT Decorative Grille InstallationOne-Foot Decorative Grille Bracket Joint Piece and Reinforcement Decorative GrilleReinforcement Joint PieceReflector joint piece End Piece and Reflector End CapSilicone Cap Installation Protective Grille InstallationCRV-Series Classic Cast-Iron Components EP-200 Condensate Valve Assembly Pump InstallationEP-100 Horizontal Venting Configurations Vertical Venting ConfigurationVenting Horizontal Venting 4 10 CM Pipe18 46 cm Minimum EP-200 Series Horizontal Venting ConfigurationsEP-300 Series Horizontal Venting Configurations Air Supply Blower Support Filter Housing AssemblyOutside Combustion AIR Supply Pressurized Outside Air Supply Pressure SwitchNon-Pressurized Outside Air Supply Vent Cap30 cm Stainless Steel Flex Gas Connection with Stainless Steel Flex Gas ConnectorGAS Piping One Zone Operation without Control Panel WiringDpst 12A Transformer Relay Zone Thermostat Purple Red Two Zone Operation without Control PanelBlack White Red/YellowGAS Valve Ignition Module CRV-Series Burner Internal WiringGasket Burner to Mixing Chamber Transformer Internal Burner DiagramLimitations on Authority Representatives Warranty is Void ifROBERTS-GORDON will not PAY for

CRV-Series specifications

The Roberts Gordon CRV-Series is a revolutionary line of infrared heating systems designed to provide efficient and effective solutions for a variety of industrial and commercial applications. With an emphasis on energy efficiency, performance, and reliability, the CRV-Series stands out as a preferred choice among business owners looking to optimize their heating solutions.

One of the main features of the CRV-Series is its innovative heating technology. The systems utilize infrared radiation to directly warm objects and individuals in a space, rather than heating the air. This results in faster heating times and a more comfortable environment, as it reduces heat loss and minimizes the need to overly heat the air itself. Consequently, users enjoy lower energy bills and improved comfort levels.

The CRV-Series is available in various configurations, allowing for versatility in installation and use. The modular design means that units can be easily adapted to suit different space requirements, whether in warehouses, manufacturing plants, or retail environments. This adaptability is complemented by a range of heating capacities, ensuring that businesses can find a model that fits their unique needs.

Another key characteristic of the CRV-Series is its robust construction. Built with high-quality materials, the systems are designed to withstand the rigors of industrial settings. This durability contributes to their long operational lifespan, reducing the need for frequent replacements and minimizing downtime.

Safety is also a paramount concern addressed by the CRV-Series. The systems are equipped with advanced safety features such as flame detection, automatic shut-off valves, and over-temperature protection. These features not only ensure safe operations but also provide peace of mind to users.

In terms of control and efficiency, the CRV-Series is compatible with advanced control systems that enable precise temperature regulation. This capability allows businesses to tailor their heating operations to match production schedules or occupancy levels, further enhancing energy savings.

Overall, the Roberts Gordon CRV-Series represents a blend of innovative technology, energy efficiency, and durability tailored for today's industrial and commercial environments. With its direct heating capabilities and robust features, it stands as a leading choice for businesses looking to improve their heating strategies while minimizing costs and environmental impact. Through its commitment to quality and performance, Roberts Gordon continues to set the standard in infrared heating technology with the CRV-Series.