Roberts Gorden CRV-Series service manual General Specifications

Page 5

ROBERTS GORDON ® CRV-SE RI ES SUBM ITT AL SHE ET

GENERAL SPECIFICATIONS

Suspension Specifications

Material Specification

Hang heater with materials with a minimum working

Reflectors

load of 75 lbs (33 kg).

.024 Mill Finish Aluminium (Optional - 024 Stainless

Controls Specifications

Steel Type 304).

Time switches, thermostats, etc. can be wired into

Heater Specifications

the electrical supply. External controls supplied as an

Ignition

option.

 

Fully Automatic, Three-Try, Direct Spark, Electronic

 

Ignition Control, 100% Safety Shut-Off.

General Specifications for CRV-Series heaters are as follows:

 

9 1/2"

6 1/2"

 

 

(24 cm)

 

(16 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14 1/4"

(36 cm)

10 3/4"

4"

Length "A"

 

(27 cm)

(10 cm)

 

6 7/8"

 

 

(17 cm)

7 5/8"

 

 

(19 cm)

 

 

3 1/2"

Reflector

 

 

 

(9 cm)

 

5/32"

 

 

 

10"

 

 

 

20"

(24.4 cm)

(.4 cm)

 

 

 

(51 cm)

 

 

Heat Input Rate

Length “A”

Recommended Minimum

 

Mounting Height*

 

 

 

 

 

 

 

 

 

Model

(BTUH X1000)

Minimum

Maximum

Spot Heating

 

 

 

 

 

CRV-B-2 (NG only)

20

10' (3 m)

20' (6.1 m)

8' (2.4 m)

 

 

 

 

 

CRV-B-4

40

12.5' (3.8 m)

25' (7.6 m)

8' (2.4 m)

 

 

 

 

 

CRV-B-6

60

20' (6.1 m)

35' (10.7 m)

8' (2.4 m)

 

 

 

 

 

CRV-B-8

80

20' (6.1 m)

45' (13.7 m)

10' (3 m)

 

 

 

 

 

CRV-B-9

90

25' (7.6 m)

50' (15.2 m)

10' (3 m)

 

 

 

 

 

CRV-B-10

100

30' (9.1 m)

60' (18.3 m)

15' (4.5 m)

 

 

 

 

 

CRV-B-12A (NG only)

110

35' (10.7 m)

70' (21.3 m)

15' (4.5 m)

 

 

 

 

 

CRV-B-12 (LP only)

120

35' (10.7 m)

70' (21.3 m)

15' (4.5 m)

 

 

 

 

 

Pipe Connection

1/2" NPT

(36" Stainless Steel Flex Included with Burner)

Dimensions

Vent Connection Size: 4" (10 cm) or 6" (15 cm)

Outside Air Connection Size: 4" (10 cm)

Refer to figure above for dimensional information.

Gas Inlet Pressure

Natural Gas: 4.5" w.c. Minimum 14.0" w.c. Maximum

LP Gas:

10.5" w.c. Minimum 14.0" w.c. Maximum

Electrical Rating

120V - 60 Hz., 0.3 Amp

Ignition System

Fully Automatic, Three-Try, Direct Spark, Electronic Ignition Control, 100% Shut-Off

© 2004 Roberts-GordonBEFORE INSTALLATIO N AND OPERATI ON OF HEATIN G EQUI PMENT, READ AND UNDERSTAND THE I NSTALLATION, O PERATION AND SERVICE MANUAL .

APPLI CATIONS, ENGIN EERING AND DETAI LED GUIDANCE ON SYSTEMS DESI GN, I NSTALLATION AND PRODUCT PERFORMANCE I S AVAILABLE UPO N REQUEST. ROBERTS GO RDON® PRODUCTS ARE TO BE INSTALLED ONLY I N ACCOR DANCE WITH LOCAL LAW S, CODES AND REGULATIONS, AND ONLY BY A CONTRACTO R QUALI FIED IN THE INSTALLATION AND SERVICE OF GAS-F IRED HEATING EQUIPMEN T.

Image 5
Contents Copyright 2004 Roberts-Gordon N127602NA Rev B 07/04 Custom-Engineered, Low-Intensity Infrared Heating SystemsCommon CRV-Series Components Standard Parts ListContents of CRV-Series Burner Carton Urvccm Pump Packages and Accessories 02719105 EP-100 Pump Package General Specifications Air Supply Blower Specifications Pump SpecificationsPump Specifications Model EP-100 EP-201 EP-203 EP-301 Standard Reflector Inches Centimeters Clearances to CombustiblesOne Side Reflector Inches Centimeters Two Side Reflectors Inches CentimetersInches Centimeters Universal Shield, Position Inches Centimeters ModelBarrier Shield Inches Centimeters Foot Deco Grille Inches CentimetersCoupling Assembly Tube Adapter CRV-SERIES Assembly OverviewMajor Component Descriptions Burner Tube With LockTube and Reflector Hanger With Clamp Package AssemblyUltravac Roberts GordonCRV-Series Assembly Overview Critical Hanger Placement Heater InstallationCoupling and Tube Assembly Tube InstallationCombustion Chamber 229 cm Tube Hanger Turnbuckles 10 maximum 3 m ChamberElbow Package Configuration Coupling and Tube Assembly Tighten Slide Bar as shown belowElbow Installation Repeat a D until all tubes are assembledReflector Installation with Hole Reflector InstallationReflector Installation Per sideReflector, U-Clip and Reflector Support Installation Burner Combustion Chamber Gasket End Vent Burner InstallationTee Installation Optional Heater AccessoriesReflector Joint Installation TeeJoint Reflector Joint DetailReflector Side Extension Bracket InstallationSide Reflector Installation Standard Reflector Grille Installation TWO-FOOT Decorative Grille InstallationFrame Shield Installation ShieldDecorative Grille Bracket ONE-FOOT Decorative Grille InstallationOne-Foot Decorative Grille Bracket Joint Piece and Reinforcement Decorative GrilleReinforcement Joint PieceReflector joint piece End Piece and Reflector End CapSilicone Cap Installation Protective Grille InstallationCRV-Series Classic Cast-Iron Components EP-200 Condensate Valve Assembly Pump InstallationEP-100 Horizontal Venting Configurations Vertical Venting ConfigurationVenting Horizontal Venting 4 10 CM Pipe18 46 cm Minimum EP-200 Series Horizontal Venting ConfigurationsEP-300 Series Horizontal Venting Configurations Air Supply Blower Support Filter Housing AssemblyOutside Combustion AIR Supply Pressurized Outside Air Supply Pressure SwitchNon-Pressurized Outside Air Supply Vent Cap30 cm Stainless Steel Flex Gas Connection with Stainless Steel Flex Gas ConnectorGAS Piping One Zone Operation without Control Panel WiringDpst 12A Transformer Relay Zone Thermostat Purple Red Two Zone Operation without Control PanelBlack White Red/YellowGAS Valve Ignition Module CRV-Series Burner Internal WiringGasket Burner to Mixing Chamber Transformer Internal Burner DiagramLimitations on Authority Representatives Warranty is Void ifROBERTS-GORDON will not PAY for

CRV-Series specifications

The Roberts Gordon CRV-Series is a revolutionary line of infrared heating systems designed to provide efficient and effective solutions for a variety of industrial and commercial applications. With an emphasis on energy efficiency, performance, and reliability, the CRV-Series stands out as a preferred choice among business owners looking to optimize their heating solutions.

One of the main features of the CRV-Series is its innovative heating technology. The systems utilize infrared radiation to directly warm objects and individuals in a space, rather than heating the air. This results in faster heating times and a more comfortable environment, as it reduces heat loss and minimizes the need to overly heat the air itself. Consequently, users enjoy lower energy bills and improved comfort levels.

The CRV-Series is available in various configurations, allowing for versatility in installation and use. The modular design means that units can be easily adapted to suit different space requirements, whether in warehouses, manufacturing plants, or retail environments. This adaptability is complemented by a range of heating capacities, ensuring that businesses can find a model that fits their unique needs.

Another key characteristic of the CRV-Series is its robust construction. Built with high-quality materials, the systems are designed to withstand the rigors of industrial settings. This durability contributes to their long operational lifespan, reducing the need for frequent replacements and minimizing downtime.

Safety is also a paramount concern addressed by the CRV-Series. The systems are equipped with advanced safety features such as flame detection, automatic shut-off valves, and over-temperature protection. These features not only ensure safe operations but also provide peace of mind to users.

In terms of control and efficiency, the CRV-Series is compatible with advanced control systems that enable precise temperature regulation. This capability allows businesses to tailor their heating operations to match production schedules or occupancy levels, further enhancing energy savings.

Overall, the Roberts Gordon CRV-Series represents a blend of innovative technology, energy efficiency, and durability tailored for today's industrial and commercial environments. With its direct heating capabilities and robust features, it stands as a leading choice for businesses looking to improve their heating strategies while minimizing costs and environmental impact. Through its commitment to quality and performance, Roberts Gordon continues to set the standard in infrared heating technology with the CRV-Series.