Using the Enhanced Write Filter user interface
In addition to the DOS
To access the EWF user interface using Administrative Tools, follow these steps:
1.Log on as an administrator.
2.Select Start > Control Panel > Performance and Maintenance > Administrative Tools.
3.Click the EWF Manager icon.
4.Use the EWF user interface to select Write Filter options.
The EWF user interface includes the following buttons:
●Enable EWF
Enables the Enhanced Write Filter so that data written to the protected media is cached in the overlays. The current overlay level becomes 1 as soon as EWF is started, and a new overlay is created at level 1.
●Disable EWF
Disables the overlay on the specified protected volume.
●Overlay configuration
Displays the overlay information and is a combination of the information supplied when executing ewfmgr.exe c:
●Clear boot command
Clears the boot command from the DOS prompt.
●Commit data to volume
Commits all