OPERATING INSTRUCTIONS
LIGHTING INSTRUCTIONS
1.STOP! Read the safety information on the previous page.
2.Turn off all electrical power and open the access door.
3.Turn off the rear burner and set the front burner to low.
4.Push in gas control (knob 1) slightly and turn
clockwise to "OFF".
KNOB 3
| 3. REAR BURNER |
| |
Meritik M A X I T R O L | OFF | MIN |
|
| ON | MAX |
|
OFF | ON |
|
|
N |
|
| |
|
|
| |
IG |
|
|
|
PILOT |
|
|
|
1. PILOT | KNOB 1 | 2. FRONT BURNER | KNOB 2 |
|
|
NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.
5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information on the previous page. If you don't
smell gas, go on to the next step.
PILOT LOCATION
TOP VIEW OF BURNER ASSEMBLY
6.Push in the control (knob 1) all the way and
rotate
7.Turn gas control (knob1)
to "ON".
8.Set the front burner (knob 2) to the desired
setting rotating
MAX. and clockwise to MIN.
9.Set the rear burner (knob 3) to the desired
setting rotating
10.Close access door and turn on electrical power.
TURN OFF GAS TO APPLIANCE
1.Open access door.
2.Set front burner to Min. and turn off the rear burner by depressing knob and rotating clockwise
until stop.
3.Unplug all electric power (optional blower) if service is to be performed.
4.Push in gas control knob slightly and turn clockwise to "OFF". Do not force.
5.Close access door.
12