| SPECIFICATIONS | |||
Natural Gas |
|
|
|
|
|
|
| |
Manifold Pressure Setting 4" w.c. |
|
|
|
|
|
|
| |
GasInletPressure Maximum |
|
|
|
|
|
| ||
Minimum 5" w.c. |
|
|
|
|
|
| ||
|
|
| GasRate |
|
| Number | ||
|
|
|
| |||||
Model Number |
| Type | Max BTU/Hr |
| Min BTU/Hr |
|
| ofBurners |
|
| |||||||
|
|
|
|
|
|
|
|
|
9830N |
| Manual | 30,000 |
| 8,000 |
|
| 2 |
|
|
|
|
|
|
|
|
|
Propane / LPG |
|
|
|
|
|
|
| |
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c. |
| |||||||
Manifold Pressure Setting 10" w.c. |
|
|
|
|
|
|
| |
GasInletPressure Maximum 13" w.c. |
|
|
|
|
|
| ||
Minimum 11" w.c. |
|
|
|
|
|
| ||
|
|
| GasRate |
|
| Number | ||
|
|
|
| |||||
Model Number |
| Type | Max BTU/Hr |
| Min BTU/Hr |
|
| ofBurners |
|
| |||||||
|
|
|
|
|
|
|
|
|
9830L |
| Manual | 30,000 |
| 8,000 |
|
| 2 |
|
|
|
|
|
|
|
|
|
Controls - Main control has 4 positions:
1.OFF - All gas to the gas logs is shut off at the control
2.IGN - Piezo ignitor allows ignition of the pilot without the use of matches or batteries
3.PILOT - Valve position to light / maintain a standing pilot
4.ON - Gas flow to complete system, front burner ignition
Front Burner Control Knob - Infinite control, rotate clockwise to minimum rate and counter
clockwise for maximum rate.
Rear Burner Control Knob - Has 3 positions:
1.OFF - Gas to rear burner is shutoff at control
2.ON/MAX - Maximum gas flow to rear burner
3.MIN - Minimum gas flow rate to rear burner
CONTENTS
9830Land9830NUnventedGasHeaters
1.PacketcontainingHomeowners/Installationinstructions.
2.Log box containing four (4) fiber ceramic logs, refer to installation instructions.
3.Unventedgasheater.
CHECK THAT ALL LISTED PARTS HAVE BEEN RECEIVED
CAUTION
GLOVES ARE RECOMMENDED WHEN HANDLING CERAMIC FIBER LOGS TO PREVENT SKIN IRRITATION FROM LOOSE FIBERS. LOGS ARE FRAGILE, HANDLE WITH CARE.
Carefully inspect the contents for shipping damage and immediately inform your dealer if any damage is found.
5