United States Stove 2007 owner manual Rules for Connector Pipe Installation

Page 10

RULES FOR CONNECTOR PIPE INSTALLATION

1.Crimped end of the pipe must be installed toward the heater. The pipe should slide inside the flue collar. The pipe should be firmly attached to the flue collar with 3 screws and sealed with furnace cement.

2.Slope any horizontal pipe upward toward the chimney at least 1/4 " inch for each foot of horizontal run.

3.You must have at least 18" inches clearance between any horizon- tal piping and the ceiling.

4.The pipe cannot extend into the chimney flue.(Fig. 8)

5.Seal each connector pipe joint with furnace cement. Also seal the pipe at the chimney.

6.Use 3 sheet metal screws at each joint to make the piping rigid.

7.It is recommended that no more than two (2) 90 degree bends be used in the stove pipe installation as more than two (2) may decrease the amount of draw and possibly cause smoke spillage.

8.The chimney connector must not pass through an attic or roof space, closet, or any concealed space, or floor, ceiling, wall or combustible construction.

Fig. 8

10

Image 10
Contents Ussc Congratulations Tools and materials neededSafety Rules Keep the firebox section free of excess ashesLocating the Room Heater Minimum Clearance to Combustible WallsMounting CAST-IRON Flue Collar Chimney Connection Venting Into a Fireplace Page Fireplace Installation Contd Fireplace InstallationRules for Connector Pipe Installation Operating Instructions Repair Parts for Parts List for Model Wiring Diagram for ModelBrick Placement TOP Inside View of Firebox Glass Replacement Instructions for ModelPage HOW to Order Repair Parts