United States Stove 5500XL owner manual Installation Options, Floor Protection

Page 5

Installation

INSTALLATION OPTIONS

Read this entire manual before you install and use your King/Ashley stove. Failure to follow instructions may result in property damage, bodily injury, or even death!

(See specific installation details for clearances and other installation requirements)

A Freestanding Unit—supported by pedestal/legs and placed on a non-combustible floor surface in compliance with clearance requirements for a freestanding stove installation.

An Alcove Unit—supported by pedestal/legs and placed on a non-combustible floor surface in compliance with clearance requirements for an alcove installation.

Your King/Ashley stove may be installed to code in either a conventional or mobile home (see SPECIAL MOBILE HOME REQUIREMENTS).

It is recommended that only a authorized technician install your King/Ashley stove, preferably an NFI certified specialist.

IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by the mal- function of a stove due to improper venting or installation. Call (800) 750-2723 and/or consult a professional installer if you have any questions.

FLOOR PROTECTION

This unit must be installed on a non-combustible floor surface. If a floor pad is used, it should be UL listed or equal. The floor pad or non-combustible surface should be large enough to extend a minimum of 6-inches in front, 6-inches on each side, and 1-inch behind the stove (see FIGURE 1).

Floor protection must extend under and 2-inches to each side of the chimney tee for an interior vertical installation (see FIGURE 2).

Your King/Ashley stove will need a minimum 31” x 38” floor protector. A Floor Protector of 1 inch thick is recommended for this installation.

USSC

5

Image 5
Contents King/Ashley Pellet Stove Table of Contents Safety Precautions Fuel Considerations SpecificationsSafety and EPA Compliance Floor Protection InstallationInstallation Options Clearances Venting Requirements Pellet Vent InstallationMaximum Venting Distance Pellet Vent TypeVent Termination Clearances Through the ROOF/CEILING Installation Through the Wall Installation Recommended InstallationSpecial Mobile Home Requirements Outside AIR Supply optionalHOW Your Stove Works OperationPerforming a DRY RUN Control PanelUnit Preparation Shut Down Procedure START-UP ProcedureSafety and Convenience Features MaintenanceDaily Operation Exhaust SystemInterior Chambers Check and Clean the HopperASH Disposal Main Door GasketsProblem Trouble ShootingParts Diagram model 5500 and 5500XL Title Qty Parts Diagram/List models 5500 & 5500XLParts List model 5500 & 5500XL HOW to Order Repair Parts