United States Stove 5500XL owner manual Trouble Shooting, Problem

Page 16

Trouble Shooting

Disconnect the power cord before performing any maintenance! NOTE: Turning the ON/OFF Switch to ”OFF” does not disconnect all power to the electrical components of the stove.

Never try to repair or replace any part of the stove unless instructions for doing so are given in this manual. All other work should be done by a trained technician.

PROBLEM

CAUSE: To rich air/fuel mixture

Orange, lazy flame_excessive fuel

Clean out the burnpot and burnpot housing

build-up in the burnpot

Make sure that the viewing door is closed and sealed properly. If not,

 

 

adjust door catch and/or replace door gaskets.

 

Check that all outside connections are clear of any obstructions.

 

Check the exhaust system; clean as needed.

 

 

 

 

PROBLEM

CAUSE: Burnpot burns out of fuel

Fire goes out or stove shuts down.

Hopper is empty, refill the hopper.

 

Loss of draft pressure. Make sure that the viewing door is closed and

 

sealed properly. If not, adjust door catch and/or replace door gaskets.

 

Check that all outside connections are clear of any obstructions. Check

 

the exhaust system; clean as needed.

 

Check that the pressure switch connection to the firebox is free of ash or

 

clear of obstructions.

 

Auger system is jammed or there is a “bridging” of the fuel in the hopper,

 

preventing fuel from flowing into the auger feed system.

 

 

PROBLEM

CAUSE: Auto-Start Igniter fails to ignite the fuel in the burn pot.

Stove does not start a fire when the

Turn the stove “OFF”. Clear the unburnt fuel from the burnpot and try

“ON” button is pushed

again.

 

Check the pellet quality. Repplace if moist, wet, or dirty.

 

Loss of draft pressure. Make sure that the viewing door is closed and

 

sealed properly. If not, adjust door catch and/or replace door gaskets.

 

Check that all outside connections are clear of any obstructions. Check

 

the exhaust system; clean as needed.

 

Check that the auto-start igniter is not blocked with ash or soot. (The

 

igniter is located behind the burnpot on the back wall of the firebox.)

 

Check that the pressure switch connection to the firebox is free of ash or

 

clear of obstructions.

 

The auto-start igniter gets “red hot” during start-up. If you can not visibly

 

see the igniter glowing during start-up, then the igniter may need to be

 

replaced or there is a problem with the electrical control system.

16

USSC

Image 16
Contents King/Ashley Pellet Stove Table of Contents Safety Precautions Safety and EPA Compliance SpecificationsFuel Considerations Installation Options InstallationFloor Protection Clearances Pellet Vent Installation Venting RequirementsMaximum Venting Distance Pellet Vent TypeVent Termination Clearances Through the Wall Installation Recommended Installation Through the ROOF/CEILING InstallationOutside AIR Supply optional Special Mobile Home RequirementsOperation HOW Your Stove WorksUnit Preparation Control PanelPerforming a DRY RUN START-UP Procedure Shut Down ProcedureMaintenance Safety and Convenience FeaturesDaily Operation Exhaust SystemCheck and Clean the Hopper Interior ChambersASH Disposal Main Door GasketsTrouble Shooting ProblemParts Diagram model 5500 and 5500XL Parts Diagram/List models 5500 & 5500XL Title QtyParts List model 5500 & 5500XL HOW to Order Repair Parts