United States Stove 6039I owner manual Glass MAINTENANCE, Removal and Replacement

Page 17

GLASS MAINTENANCE, REMOVAL AND REPLACEMENT

Your American Harvest Multifuel Stove comes to you with the glass door installed in place, ready for use. The glass is surrounded on the edges with a gasket and seated in a glass channel. It is held in place with two (2) clips.

REMOVAL OF BROKEN OR DAMAGED CERAMIC GLASS

Open the door and lift off of hinges. If the door is tight, tap gently on the bottom of the door with your hand or rubber hammer. Lay door down on newspaper with glass clips facing you. Using a #2 Phillips screwdriver, loosen the screws and take off the glass clips. Remove the broken glass carefully and discard.

Reverse the above procedure for replacing new glass with new gasket. Do not over tighten the screws. Over tightening can cause the glass to break.

WARNING

Do not operate unit with broken glass.

Do not substitute original factory glass.

You must use only factory authorized glass;

Do not slam door shut.

Do not strike glass.

Do not use abrasive cleaners.

Do not clean when glass is hot.

CLEANING THE GLASS

When the fire is first started, it will produce some smoke. The soot might accumulate on the glass surface. Before the glass surface gets hot, open the door and wipe the glass surface off with a rag. Do not touch the surface with your hands. If after constant use, the glass is dirty, you must clean the glass so that it will not become etched with the fly ash. When the glass has cooled off, take a damp ragand clean with Hearth Glass Cleaner available from your dealer. Do not use a rag that contains nylon because it will melt to the glass.

-

GLASS CLIPS

.

USSC

17

Image 17
Contents 6039, 6039I, 6039T Congratulations Specifications6039T Assembly AssemblyPedestal Trim Assembly Disconnect the Power Cord Before Servicing this Stove 6039I AssemblyComponent Location Burning Solid Fuels Safety StepsContent Installation RequirementsHearth Protection Clearances to Combustibles 6039TClearances to Combustibles Vent Termination Clearances Guidelines for Exhaust Venting Systems DesignDesign Guidelines for Outside Combustion AIR Connection Mobile Home Installation Requirements Installation ConfigurationsDimensional tolerance ±1/4 Ussc Installation AS ABUILT-INFIREPLACE Design Guidelines for 6039I Insert InstallationINSTALLATIONINTOAFACTORY-BUILT Metal Fireplace Installation Into a Masonry FireplaceRemoval of Broken or Damaged Ceramic Glass Glass MAINTENANCE, Removal and ReplacementControl Panel Understanding the Control BoardTo Start Lighting InstructionsDisposal of Ashes Maintenance InstructionsSPECIALCLEANING/OPERATIONAL Instructions Fuel Additive Automatic Safety FeaturesSTART-UP Sequence of Events Circuit Board FunctionsError Codes and Display Indicators Problem Trouble ShootingWiring Diagram Repair Parts DIAGRAM-6039 Repair Parts LIST-6039 Repair PARTS-6039I Repair Parts LIST-6039I 6039T Parts Diagram & List Ussc HOW to Order Repair Parts