DESIGN GUIDELINES FOR 6039I INSERT INSTALLATION

INSTALLATION AS ABUILT-INFIREPLACE

A continuous sheet of non-combustible floor protection must be installed underneath the unit to prevent the possibility of embers falling through to the combustible floor. If the floor beneath the unit is of non-combustible material, the protector is not required.

See the “Clearance to Combustibles” section of this manual for installation clearances.

Alternative Exhaust Venting

Depending on your installtion, you might consider routing your cleanout tee as illustrated below for ease of cleaning. The access panel in the right side facade allows you to reach the tee from the front side of the unit if venting is assembled as shown. The cleanout tee is attached to a 90° elbow mounted to the unit then rotated at approx. 15-20 degrees. A 12 inch section of “PL” vent is connected to reach the top of the unit to which a flexible pipe may be attached for further termination through a chimney. Clearance to combus- tibles must be considered if this installation is chosen. A distance of 3 inches must be maintained from the exhaust vent to any combustible material.

USSC

15

Image 15
Contents 6039, 6039I, 6039T Congratulations SpecificationsAssembly Pedestal Trim Assembly6039T Assembly Disconnect the Power Cord Before Servicing this Stove 6039I AssemblyComponent Location Burning Solid Fuels Safety StepsContent Installation RequirementsHearth Protection Clearances to Combustibles 6039TClearances to Combustibles Vent Termination Clearances Guidelines for Exhaust Venting Systems DesignDesign Guidelines for Outside Combustion AIR Connection Mobile Home Installation Requirements Installation ConfigurationsDimensional tolerance ±1/4 Ussc Installation AS ABUILT-INFIREPLACE Design Guidelines for 6039I Insert InstallationINSTALLATIONINTOAFACTORY-BUILT Metal Fireplace Installation Into a Masonry FireplaceRemoval of Broken or Damaged Ceramic Glass Glass MAINTENANCE, Removal and ReplacementControl Panel Understanding the Control BoardTo Start Lighting InstructionsMaintenance Instructions SPECIALCLEANING/OPERATIONAL InstructionsDisposal of Ashes Fuel Additive Automatic Safety FeaturesSTART-UP Sequence of Events Circuit Board FunctionsError Codes and Display Indicators Problem Trouble ShootingWiring Diagram Repair Parts DIAGRAM-6039 Repair Parts LIST-6039 Repair PARTS-6039I Repair Parts LIST-6039I 6039T Parts Diagram & List Ussc HOW to Order Repair Parts