After the issue is resolved, any disk can be added (which might involve upgrading the virtual hardware on the virtual machine.)
Server is unresponsive during PSP installation
The server becomes unresponsive during PSP installation.
Suggested action
Reboot the server and then reinstall PSP manually.
Destination server still shows server migration UI but server migration wizard shows migration completed
After the migration, server migration loses connectivity to the
Suggested action
Manually eject the virtual boot CD from the VM and reboot the VM.
Operating system is not booting on a destination server that has SAN disks
After you perform a successful P2P migration of the SLES 11 SP1
Suggested action
Before you migrate any Linux distribution to a destination server that has SAN storage, make sure that the RPM package containing firmware files (such as
Error is displayed for a missing file system while migrated Linux OS is booted on the destination server
When you migrate a file system to the destination server multiple times, the multiple file systems that contain the same UUID are created.
Suggested action
Make sure that multipath is configured on the source server. If multipath is not configured, make sure that the file systems that are being migrated do not have the same UUID.
Logical drives of HP Smart Array B110i SATA RAID Controller are removed
After a successful X2P migration of the Windows Server 2008 OS, the logical drives of HP Smart Array B110i SATA RAID Controller are removed.
Suggested action
When the logical drives are removed, you must
70 Troubleshooting