United States Stove 2000, 2500 instruction manual Floor Protector

Page 6

FLOOR PROTECTOR

Your wood stove should be placed on a 1 inch, non-combustible surface with a k factor of 0.84. For multiple layers, add R-values of each layer to determine the overall R-value. The R value for the required board is 1.2. The floor protector should be under the stove, twenty-six inches beyond the front and six inches beyond each side of the fuel loading and ash removal opening. If there is a horizontal section of chimney connector, the floor protector should go under it and two inches beyond each side

Convert specification to R-value:

k-factor is given with a required thickness (T) in inches: R=1/k x T

C-factor is given: R=1/C

Example:

If the floor protector is 4” brick with a C-factor of 1.25 over 1/8” mineral board with a “k”

factor of 0.29 the total R-value of the system is: 4” brick C=1.25, R=1/1.25=0.8

1/8” mineral board K=0.29, R=1/0.29 x 0.125=0.431 Total R = Rbrick + Rmineral = 0.8 + 0.431 = 1.231 Total R is greater than 1.2, the system is acceptable.

The floor protector should exceed the stove as follows:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Front

Sides

Rear

 

 

 

 

 

 

 

 

 

 

2000

25”

8”

6”

 

 

 

 

 

 

 

 

 

 

2500

26”

8”

6”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Ussc

Image 6
Contents Ussc Congratulations Tools and Materials Needed For Installation Blower Assembly Instructions Pedestal Trim AssemblyInstallation Safety NoticePositioning the Stove Floor Protector Clearances to Combustibles ModelChimney Connector Stove Pipe Chimney Factory Built Chimney Masonry Chimney Combustible Wall Chimney Connector Pass-Throughs Outside Combustion AIR For use in Mobile HomesTesting Your Wood Woodstove UtilizationFirst Fires IgnitionHeating Reloading To Prevent Creosote Build UPGlass MaintenanceASH Disposal GasketingRepair Parts Key Part No. Description Model Qty HOW to Order Repair Parts United States Stove Company