Lochinvar SPS0250, SPS0500, PS1000 operation manual General Information

Page 3

SL-PS Installation & Operation Manual

1 General Information

￿WARNING

￿WARNING

￿WARNING

￿WARNING

￿WARNING

￿WARNING

￿WARNING

￿WARNING

Before starting work, the Installer must read, understand and note these installation and operating instructions.

The solar pump station may only be installed and maintained by trained professionals. Trainees may only work on the product under the supervision of an experienced person.

All instructions in this Installation & Operation manual should be observed when using the solar station. No other form of use is intended.The manufacturer is not liable for any damage resulting from misuse of the solar station. For safety reasons, modifications or changes are not permitted.

The solar station must be installed as far away from the collectors as possible. Extremely high temperatures may occur in the pipes near the collectors. If installing in attic space, ensure that the instruments do not overheat.

The pressure / temperature operating parameters must be within the prescribed limits. Excess operating temperatures should be avoided for continuous operation.

The provisions stated in DIN EN 12976-1 should be observed when installing solar systems.

The expansion tank should be regularly checked according to DIN 4807.

Solar systems should be grounded to protect against lightning.

The system’s electrical connection for sensors and voltage supply should only be established by a trained professional. The relevant specifications (VDE 0100, VDE 0185, VDE 0190 etc.) should be observed as well as special local (construction) requirements. (Grey cable = tank, black cable

=collector)

The solar pump station’s componentry varies depending on type and equipment.

The diagrams used are examples.

Subject to technical changes and further developments.

A properly sized expansion tank must be used to avoid damage to the solar thermal system.

Thermal expansion tanks should be sized to account for 1.5 times the solar system circuit volume.

The expansion tank may be hot, ensure that scalding does not occur.

Failure to heed these instructions, especially the safety instructions, can result in the destruction of and defects on the expansion tank, endanger persons, and impair the operation.

3

Image 3
Contents Solar Pump Station Installation and Operation ManualContents General Information Technical documentation Installation kitSolar Station Solar Control unitInstallation, connection lines to tank and collector Installing the solar stationInstalling the solar station on a wall Installing the relief valveTechnology, installation and commissioning Flat seal screw connectionsOperation, multi-function ball valve and check valve Filling, flushing and bleeding Commissioning the solar systemSPS0250 Pressure loss and residual delivery heightVFS flow sensor VFS 1-12 output signal flowDesignation SPS0250 / SPS0500 SPS1000 Technical data for solar stationDesignation SPS0250 / SPS0500 SPS1000 SPS0250/ SPS0500 Component breakdownSPS1000 Clamp ring screw connections ServiceDraining the system Air separatorPump Noise Faults, causes and rectificationPump doesn’t run when power is switched on Motor blockedRevision Notes Revision a ECO C06520 initial release