| User’s Manual DRF Series |
| |
TECHNICAL DATA : Models | |||
INPUT SIGNAL for POTENTIOMETER |
|
| |
RANGES | 0/100 % | StandardDINrailmounting,asspecified | |
| 0/50 % | on DIN46277 and DIN EN 50022 | |
| 0/25 % | 37.5 x 7.5 mm (1.38 x 0.3 ´´) | |
| 0/12.5% |
|
|
| (minimum 8%) | GALVANIC ISOLATION LEVELS | |
Potentiometer value min 100Ohms | DCUnits |
| |
Input - Output | 3.5 KV (60 seconds) | ||
| max 1MOhm | 3.5 KV (60 seconds) | |
3 Wire System, 1 Vdc Excitation | Power- Output | 1 KV (60 seconds) | |
INPUT SIGNAL in RESISTANCE | ACUnits |
| |
RANGES | 0/10 KOhms | Input - Output | 3.5 KV (60 seconds) |
| 0/5 KOhms | Power- Input | 3.5 KV (60 seconds) |
| 0/3 KOhms | Power - Output 3.5 KV (60 seconds) | |
| 0/1.5 KOhms |
|
|
(minimum 750 Ohms)
2 Wire System, 0.2 mA Excitation
OUTPUT SIGNAL in VDC
RANGES | 0/10 Vdc |
| 0/1 Vdc |
Max Output | 11Vdc approx. |
All isolation levels are tested during a time of 60 seconds, with current leaks <1mA
Note : Indicated isolation levels are also
sometimes named as STRENGTHENED ISOLATION levels, for systems with
Polution Level 2
Min Output | |
Min Load R | ≥ 1KOhm |
OUTPUT SIGNAL in mA | |
RANGES | 0/20mA (4/20mA) |
Max Output | 22mA approx. |
Min Output | |
Max Load R | ≤ 400 Ohms |
POWER SUPPLY | |
DC Power | 24Vdc ±10% |
AC Power | 230Vac ±10% 50/60 Hz |
| 115Vac ±10% 50/60 Hz |
Consumption | <3.8VA |
GENERALSPECIFICATIONS
Accuracy | <0.2% F.S. |
Optimized for | 12 bit systems |
Linearity | <0.1% F.S. |
Thermal Drift | <250 ppm/ºC Tipical |
5 minutes |
Response Time <70mS (90% of signal)
Protection | |
Temp.Operation from 0 to 60ºC | |
Temp.Storage | from |
MECHANICALDIMENSIONS | MATERIALS | ||
DC Units | 22.5 x 93 x 110 mm | Box and Cover in Poliamide PA6 UL94 | |
AC Units | 37.0 x 93 x 110 mm | ||
Weight DC | 120 gr. | ||
Terminals in Poliamide UL94 | |||
Weight AC | 200 gr. |
|
Page 9